W DOC AIRBUS | AMM A320F

Installation of the Pylon Fire Detectors without the Tool (98D26203003000)


TASK 26-12-16-400-001-A-01
Installation of the Pylon Fire Detectors without the Tool (98D26203003000)


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
NOTE: There are alternative methods for this procedure. This task gives one of the methods: installation without the tool (98D26203003000).
FIN: 3WD1 ** ON A/C NOT FOR ALL
FIN: 3WD2 ** ON A/C NOT FOR ALL
FIN: 4WD1 ** ON A/C NOT FOR ALL
FIN: 4WD2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 26-12-00-710-001-A
Operational Check of Loop/Squib
TASK 26-12-16-400-002-A
Installation of the Support with the Pylon Fire Detectors
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
TASK 78-36-00-010-040-A
Opening of the Thrust Reverser Doors
TASK 78-36-00-010-040-B
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-A
Closing of the Thrust Reverser Doors
TASK 78-36-00-410-040-B
Closing of the Thrust Reverser Doors
3. Job Set-up
Subtask 26-12-16-860-056-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Make sure that the ENG/MODE/CRANK/NORM/IGN/START selector switch is in the NORM position.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
   (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
   (3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 26-12-16-865-056-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1000EM1 (ENGINE1)
49VUENGINE/1/FIRE DET/LOOP A7WD1A06
121VUENGINE/ENG1/FIRE DET/LOOP B8WD1Q38
FOR FIN: 1000EM2 (ENGINE2)
49VUENGINE/2/FIRE DET/LOOP B8WD2A07
121VUENGINE/ENG2/FIRE DET/LOOP A7WD2Q39
Subtask 26-12-16-010-059-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Make sure that the thrust reverser doors are open (Ref. AMM TASK 78-36-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 26-12-16-040-054-A ** ON A/C NOT FOR ALL
D. Make sure that the thrust reverser is unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 26-12-16-010-059-B ** ON A/C NOT FOR ALL
E. Get Access
   (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Make sure that the thrust reverser halves are open (Ref. AMM TASK 78-32-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 26-12-16-040-054-B ** ON A/C NOT FOR ALL
F. Make sure that the thrust reverser Hydraulic Control Unit (HCU) is deactivated (Ref. AMM TASK 78-30-00-040-012).
Subtask 26-12-16-010-059-C ** ON A/C NOT FOR ALL
G. Get Access
   (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Make sure that the thrust reverser halves are open (Ref. AMM TASK 78-36-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 26-12-16-040-054-C ** ON A/C NOT FOR ALL
H. Make sure that the thrust reverser is unserviceable (Ref. AMM TASK 78-30-00-481-041).
4. Procedure
Subtask 26-12-16-420-053-A ** ON A/C NOT FOR ALL
A. Installation of the Responders
   (1) Remove the blanking caps from the detectors (11).
NOTE: The protection rings (supplied with a new part) must not be removed from the sensing elements (4) at this time.
   (2) Install the responders (11) on their supports as follows:
     (a) Install the hexagonal nut of the responder (11) on the clamp (12).
     (b) Install the screws (8) and the washers (9).
Subtask 26-12-16-420-054-A ** ON A/C NOT FOR ALL
B. Installation of the Pylon Fire Detector
   (1) Put the bushes (3) on the sensing elements (4), then in the clamps (2).
   (2) Remove the protection rings from the sensing elements (4) and make sure that the sensing elements (4) have a minimum straight length above the responders (11).
NOTE: When you bend the sensing elements near responders, be careful not cause fatigue damage on the brazing between the responder and the sensing elements.
   (3) Follow the radius of curvative and bend the sensing elements with your hand near the support corners and the detector responders.
   (4) Close the clamps (2) and lock them with the fasteners (1).
   (5) Remove the blanking caps from the electrical connectors (7).
   (6) Connect the electrical connectors (7) to the responders (11).
Subtask 26-12-16-420-053-B ** ON A/C NOT FOR ALL
CAUTION: DO NOT BEND THE MANIFOLD OF THE SENSING ELEMENT. IF YOU BEND IT, YOU CAN CAUSE DAMAGE TO THE WELDING.
C. Installation of the Fire Detectors
NOTE: You must not remove the protection rings (supplied with a new part) from the sensing elements (9) at this time.
   (1) Install each of the two responder units (2) in the two clamps (5).
   (2) Carefully install the two responder units (2) on the rail assembly (1).
   (3) Install the two washers (3) and bolts (4) on each responder unit (2) and tighten them.
Subtask 26-12-16-420-054-B ** ON A/C NOT FOR ALL
D. Installation of the Pylon Fire Detectors
CAUTION: DO NOT BEND THE MANIFOLD OF THE SENSING ELEMENT. IF YOU BEND IT, YOU CAN CAUSE DAMAGE TO THE WELDING.
   (1) Remove the protection rings from the sensing elements (9).
   (2) Install the grommet (8) and the grommets (12) on the two sensing elements (9).
   (3) Install the sensing elements (9).
     (a) Install the sensing elements (9) in the clamps (11).
     (b) Refer to the permitted tolerances and the instructions related to the bending radius.
     (c) Bend the sensing elements (9) with your hand and adapt them to the curve radii of the support and the responder units (2).
     (d) Make sure that the grommet (8) is in the correct position on the clamp (7).
     (e) Make sure that the grommets (12) are in the correct position on the clamps (11).
   (4) Close the clamps (7) and (11).
CAUTION: DO NOT USE ELECTRICAL OR PNEUMATIC TOOLS TO LOOSEN OR TIGHTEN THE QUARTER-TURN FASTENER ON THE FIRE DETECTOR CLAMP. ONLY USE A MANUAL SCREWDRIVER. ELECTRICAL OR PNEUMATIC TOOLS WILL CAUSE THE FASTENER TO TURN TOO MUCH AND POSSIBLY TO BREAK.
     (a) Close the clamp (7) and lock it with the quarter-turn fastener (6).
     (b) Close the clamps (11) and lock them with the quarter-turn fastener (10).
Subtask 26-12-16-865-057-A ** ON A/C NOT FOR ALL
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1000EM1 (ENGINE1)
49VUENGINE/1/FIRE DET/LOOP A7WD1A06
121VUENGINE/ENG1/FIRE DET/LOOP B8WD1Q38
FOR FIN: 1000EM2 (ENGINE2)
49VUENGINE/2/FIRE DET/LOOP B8WD2A07
121VUENGINE/ENG2/FIRE DET/LOOP A7WD2Q39
Subtask 26-12-16-860-057-A ** ON A/C NOT FOR ALL
F. Do the EIS start procedure (Upper ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).
Subtask 26-12-16-710-052-A ** ON A/C NOT FOR ALL
G. Operational Test
   (1) On the upper ECAM DU, make sure that the FIRE ENG1(2) LOOP A (B) FAULT message is out of view.
   (2) Do an operational test of the engine fire-detection system (Ref. AMM TASK 26-12-00-710-001).
Subtask 26-12-16-860-058-A ** ON A/C NOT FOR ALL
H. Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
5. Close-up
Subtask 26-12-16-410-056-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install the support with the fire detectors (Ref. AMM TASK 26-12-16-400-002).
Subtask 26-12-16-410-057-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 26-12-16-440-052-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 26-12-16-410-058-A ** ON A/C NOT FOR ALL
D. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
Subtask 26-12-16-410-057-B ** ON A/C NOT FOR ALL
E. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 26-12-16-440-052-B ** ON A/C NOT FOR ALL
F. Do the re-activation of the thrust reverser HCU (Ref. AMM TASK 78-30-00-440-012).
Subtask 26-12-16-410-058-C ** ON A/C NOT FOR ALL
G. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
Subtask 26-12-16-410-057-C ** ON A/C NOT FOR ALL
H. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser halves (Ref. AMM TASK 78-36-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 26-12-16-440-052-C ** ON A/C NOT FOR ALL
I. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 26-12-16-410-058-B ** ON A/C NOT FOR ALL
J. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).