Removal of the Pylon Fire Detector
TASK 26-12-16-000-805-A
Removal of the Pylon Fire Detector
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 26-12-16-010-074-A
Subtask 26-12-16-020-065-A
[Rev.10 from 2021]
2026.03.31 23:42:56 UTC
Removal of the Pylon Fire Detector
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
YOU MUST NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE AN INJURY.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 415 | LOWER PYLON |
| 425 | LOWER PYLON |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 26-12-16-000-804-A | Removal of the Pylon Fire-Detector Ramp-Assembly |
Subtask 26-12-16-010-074-A
A. Removal of the Pylon Fire-Detector Ramp-Assembly
(1) Remove the pylon fire-detector ramp-assembly (Ref. AMM TASK 26-12-16-000-804).
4. Procedure(1) Remove the pylon fire-detector ramp-assembly (Ref. AMM TASK 26-12-16-000-804).
Subtask 26-12-16-020-065-A
A. Removal of the Fire Detector
(2) Turn the quarter-turn fasteners (8) by one quarter of a turn and open the clamps (9).
(3) Turn the quarter-turn fasteners (11) by one quarter of a turn and open the clamps (10).
(4) Remove the four screws (1) and washers (2) from each responder unit (3).
(5) Remove the two responder units (3) and the related sensing elements (7) from the rail assembly (4).
CAUTION:
DO NOT USE ELECTRICAL OR PNEUMATIC TOOLS TO LOOSEN OR TIGHTEN THE QUARTER-TURN FASTENER ON THE FIRE DETECTOR CLAMP. ONLY USE A MANUAL SCREWDRIVER. ELECTRICAL OR PNEUMATIC TOOLS WILL CAUSE THE FASTENER TO TURN TOO MUCH AND POSSIBLY TO BREAK.
CAUTION:
DO NOT BEND THE MANIFOLD OF THE SENSING ELEMENT. IF YOU BEND IT, YOU CAN CAUSE DAMAGE TO THE WELDING.
(1) Turn the quarter-turn fasteners (5) by one quarter of a turn and open the clamps (6). (2) Turn the quarter-turn fasteners (8) by one quarter of a turn and open the clamps (9).
(3) Turn the quarter-turn fasteners (11) by one quarter of a turn and open the clamps (10).
(4) Remove the four screws (1) and washers (2) from each responder unit (3).
(5) Remove the two responder units (3) and the related sensing elements (7) from the rail assembly (4).
Pylon Fire Detector