W DOC AIRBUS | AMM A320F

Removal of the ENG/APU Fire Panel


TASK 26-12-12-000-001-A
Removal of the ENG/APU Fire Panel


ZONE: 211
FIN: 1WD
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 26-12-12-941-050-A
A. Safety Precautions
   (1) In the cockpit:
     (a) On the ENG panel 115VU, put a WARNING NOTICE(S) to tell the persons not to start engines.
     (b) On the OVERHEAD CTL & IND panel 25VU, put a WARNING NOTICE(S) to tell the persons not to start APU.
Subtask 26-12-12-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/FLOW/CTL &/IND11HBD07
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
** ON A/C ALL
49VUFUEL/LP VALVE/MOT1/ENG22QGA09
49VUFUEL/LP VALVE/MOT1/ENG11QGA08
49VUENGINE/2/FIRE DET/LOOP B8WD2A07
49VUENGINE/1/FIRE DET/LOOP A7WD1A06
49VUHYD/FIRE VALVE/Y/ENG23702GDC14
49VUHYD/FIRE VALVE/G/ENG11703GKC13
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 2/MONG3HA2D12
49VUAIR BLEED/ENG 1/CTL2HA1D11
49VUHYDRAULIC/FIRE VALVE/G/ALTN1711GKH14
49VUHYDRAULIC/FIRE VALVE/Y/ALTN3712GDH13
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B2WE1Q44
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B2WE2Q42
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A1WE1Q43
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A1WE2Q41
** ON A/C ALL
121VUAPU/FIRE AND OVHT/DET/LOOP B2WGL44
121VUAPU/FIRE AND OVHT/DET/LOOP A1WGL43
121VUAPU/FIRE/EXTIG/SQUIB/B2WFL39
121VUAPU/FIRE/EXTIG/SQUIB/A1WFL38
121VUAPU/FIRE/LP VALVE/NORM4WFM42
121VUAPU/FIRE/LP VALVE/STBY3WFM41
121VUFUEL/LP VALVE/MOT2/ENG24QGM26
121VUFUEL/LP VALVE/MOT2/ENG13QGM25
121VUENGINE/ENG2/FIRE DET/LOOP A7WD2Q39
121VUENGINE/ENG1/FIRE DET/LOOP B8WD1Q38
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B2WE1Q44
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B2WE2Q42
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B2WE1Q43
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A1WE1Q42
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B2WE2Q41
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A1WE2Q40
** ON A/C NOT FOR ALL
122VUAPU GEN/EGIU2/28VDC26XU2Y31
122VUGEN2/EGIU2/28VDC24XU2Y30
122VUELEC/EXT PWR/EGIU1/28VDC26XU1Z31
122VUELEC/GEN1/EGIU1/28VDC24XU1Z30
** ON A/C NOT FOR ALL
122VUAIR COND/FLOW/CTL AND IND/22HBV21
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
** ON A/C ALL
122VUELEC/GCU/22XU2T27
122VUELEC/GCU/12XU1T26
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 1/MONG3HA1Z23
122VUAIR BLEED/ENG 2/CTL2HA2Z22
** ON A/C NOT FOR ALL
123VUGEN1/EGIU1/115VAC23XU1AF12
123VUGEN2/EGIU2/115VAC23XU2AF01
4. Procedure
Subtask 26-12-12-020-050-B
CAUTION: BE CAREFUL WHEN YOU MOVE THE FIRE PANEL. SHOCKS CAN EASILY CAUSE DAMAGE TO ITS SUBCOMPONENTS AND MAKE THEM DEFECTIVE.
A. Remove the ENG/APU Fire Panel
   (1) Hold the fire panel (2) and loosen the QAD fasteners (3) by a quarter turn.
   (2) Remove the panel (2) from its housing.
   (3) Disconnect the electrical connectors (1) from the panel (2).
   (4) Put CAP - BLANKING on the electrical connectors (1) and on the fire panel (2).
[Rev.10 from 2021] 2026.03.31 23:42:26 UTC