Visual Inspection of the Engine Fire-Detection System


TASK 26-12-00-200-803-A
Visual Inspection of the Engine Fire-Detection System


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 400
1. Reason for the Job
Use this inspection procedure to examine the engine fire and overheat detection system for correct installation and for damage.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
1
BRUSH - NON METALLIC
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
No specific
1
WATER - DEIONIZED
98D26203003001
1
CAMBERING TOOL
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR, 451AL, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 26-12-16-400-805-A
Installation of the Pylon Fire Detector
TASK 26-12-17-400-804-A
Installation of the Core Engine Fire Detection Elements
TASK 26-12-18-400-801-A
Installation of the Fan Area Fire-Detection Elements
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-803-A
Closing of the Fan Cowl Doors
TASK 78-30-00-040-809-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-30-00-440-809-A
Reactivation of the Thrust Reverser System after Ground Maintenance
TASK 78-36-00-010-806-A
Opening of the Thrust Reverser Cowl Doors
TASK 78-36-00-410-806-A
Closing of the Thrust Reverser Cowl Doors
3. Job Set-up
Subtask 26-12-00-861-059-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 26-12-00-941-055-A
B. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
     (d) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 26-12-00-865-059-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1)
49VUENGINE/1/FIRE DET/LOOP A7WD1A06
121VUENGINE/ENG1/FIRE DET/LOOP B8WD1Q38
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2)
49VUENGINE/2/FIRE DET/LOOP B8WD2A07
121VUENGINE/ENG2/FIRE DET/LOOP A7WD2Q39
Subtask 26-12-00-010-060-A
D. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
Subtask 26-12-00-040-056-A
E. Deactivation of the Thrust Reverser for Ground Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-809).
Subtask 26-12-00-010-061-A
F. Get Access
   (1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
   (2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure
CAUTION: DO NOT USE ELECTRICAL OR PNEUMATIC TOOLS TO LOOSEN OR TIGHTEN THE QUARTER-TURN FASTENER ON THE FIRE DETECTOR CLAMP. ONLY USE A MANUAL SCREWDRIVER. ELECTRICAL OR PNEUMATIC TOOLS WILL CAUSE THE FASTENER TO TURN TOO MUCH AND POSSIBLY TO BREAK.
CAUTION: DO NOT BEND THE MANIFOLD OF THE SENSING ELEMENT. IF YOU BEND IT, YOU CAN CAUSE DAMAGE TO THE WELDING.
Subtask 26-12-00-210-066-A
A. Visual Inspection of the Pylon Fire Detectors
   (1) Make sure that the minimum permitted bend radius through the manifold tube and the braze is 150 mm (6 in.) (Detail C).
   (2) Make sure that the bend radius of the sensing elements (1) is a minimum of 9.5 mm (0.37 in.) (Detail C). Use the 98D26203003001 CAMBERING TOOL to make sure that the pylon fire-detector loop is bent correctly.
   (3) Make sure that the minimum distance between the sensing elements (1) and their supports is 5 mm (0.20 in.) (Details D, E and F).
   (4) Make sure that all the clamps (3) and (6) are correctly closed and the sensing elements (1) are correctly installed. If not, close the clamps (3) and (6) with the quarter-turn fasteners (2) and (5) and/or install the sensing element(s) (1) (Ref. AMM TASK 26-12-16-400-805).
   (5) Make sure that the end of the sensing element (1) is at a maximum distance of 25.4 mm (1.00 in.) from the clamp (6).
   (6) Make sure that there is no damage or chafing on the fire detectors, the rail assemblies (4) and the related brackets.
   (7) To prevent short-circuits, make sure that there is no damage or chafing on the fire-detection harness insulations.
   (8) For MEGGITT pylon fire-detectors, go to Para. 4.D. to do the cleaning.
Subtask 26-12-00-210-067-A
B. Visual Inspection of the Core Fire Detectors
   (1) Make sure that the sensing elements (4) align with the contour of the fire-detection support rail correctly and that the minimum bend radius is 9.5 mm (0.37 in.).
   (2) Make sure that the distance between two clamp clips (9) is between 76.2 mm (3.00 in.) and 101.6 mm (4.00 in.).
   (3) Make sure that all the clamp clips (9) and bolts (10) are installed and closed correctly. If not, close the clamp clips (9) with the bolts (10) (Ref. AMM TASK 26-12-17-400-804).
   (4) Make sure that the maximum distance between the tube braze of the responders (7) and (11) and the first clamp clip is 76.2 mm (3.00 in.).
   (5) Make sure that the end of the sensing element (8) is at a maximum distance of 25.4 mm (1.00 in.) from the clamp clip (9).
   (6) Make sure that there is no damage or chafing on the fire detectors, the rail assemblies and the related brackets.
   (7) To prevent short-circuits, make sure that there is no damage or chafing on the fire-detection harness insulations.
   (8) For MEGGITT core fire-detectors, go to Para. 4.D. to do the cleaning.
Subtask 26-12-00-210-068-A
C. Visual Inspection of the Fan Area Fire-Detectors
   (1) Make sure that the sensing elements (16) and (19) align with the contour of the related fire-detection support-rail correctly and that the minimum bend radius is 9.5 mm (0.37 in.).
   (2) Make sure that the distance between two clamp clips (13) is between 76.2 mm (3.00 in.) and 101.6 mm (4.00 in.).
   (3) Make sure that all the clamp clips (13) and bolts (14) are installed and closed correctly. If not, close the clamp clips (13) with the bolts (14) (Ref. AMM TASK 26-12-18-400-801).
   (4) Make sure that the maximum distance between the tube braze of the responders (12), (15), (17) and (18) and the first clamp clip is 76.2 mm (3.00 in.).
   (5) Make sure that the ends of the sensing elements (16) and (19) are at a maximum distance of 25.4 mm (1.00 in.) from the clamp clip (13).
   (6) Make sure that there is no damage or chafing on the fire detectors, the rail assemblies and the related brackets.
   (7) To prevent short-circuits, make sure that there is no damage or chafing on the fire-detection harness insulations.
   (8) For MEGGITT fan area fire-detectors, go to Para. 4.D. to do the cleaning.
Subtask 26-12-00-100-050-A
D. Cleaning of the MEGGITT Fire Detectors
   (1) Use a BRUSH - NON METALLIC and WATER - DEIONIZED to clean the ceramic insulation header and studs of the fire detectors.
   (2) Dry the fire detectors fully.
5. Close-up
Subtask 26-12-00-410-062-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
Subtask 26-12-00-440-056-A
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-809).
Subtask 26-12-00-410-063-A
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
Subtask 26-12-00-865-060-A
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1)
49VUENGINE/1/FIRE DET/LOOP A7WD1A06
121VUENGINE/ENG1/FIRE DET/LOOP B8WD1Q38
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2)
49VUENGINE/2/FIRE DET/LOOP B8WD2A07
121VUENGINE/ENG2/FIRE DET/LOOP A7WD2Q39
Subtask 26-12-00-862-057-A
E. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).