Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF)


TASK 26-10-00-740-802-A
Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF)


ZONE: 210
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-005-A
Procedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 26-10-00-861-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (3) Do the procedure to get access to the SYSTEM REPORT/TEST FIRE PROT page
(Ref. AMM TASK 31-32-00-860-005).
Subtask 26-10-00-865-050-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DIR ESS/2157RHG02
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DEU B/ESS153RHG03
49VUCOM/CIDS/DIR ESS/1150RHG01
** ON A/C NOT FOR ALL
49VUAIR COND/CIDS/SDF/DIR2 ESS18WHC06
49VUAIR COND/CIDS/SDF/DIR1 ESS15WHC05
** ON A/C NOT FOR ALL
49VUAIR COND/CARGO FIRE/EXTIG/BTL11WXC03
** ON A/C NOT FOR ALL
49VUCOM DIR ESS/2157RHG02
** ON A/C NOT FOR ALL
49VUCOM NAV/CIDS/DIR2 ESS157RHG02
49VUCOM NAV/CIDS/DIR1 ESS150RHG01
** ON A/C NOT FOR ALL
49VUAIR COND/CARGO FIRE/EXTIG/BTL28WXC04
** ON A/C NOT FOR ALL
49VUAIR COND/CARGO/FIRE/EXTIG/BTL11WXC03
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B/NORM162RHM08
121VUCOM NAV/CIDS/DIR NORM/2156RHM06
121VUCOM NAV/CIDS/DIR NORM/1151RHM05
** ON A/C NOT FOR ALL
121VUCOM / CIDS / DEU B / NORM FWD193RHM09
121VUCOM NAV/CIDS/DIR NORM/2156RHM07
121VUCOM NAV/CIDS/DIR NORM/1151RHM06
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DIR2 NORM156RHM06
121VUCOM NAV/CIDS/DIR1 NORM151RHM05
** ON A/C NOT FOR ALL
122VUAIR COND/CARGO/FIRE/EXTIG1WXT19
** ON A/C NOT FOR ALL
122VUAIR COND/CIDS/SDF/DIR NORM/214WHT18
122VUAIR COND/CIDS/SDF/DIR NORM/117WHT17
** ON A/C NOT FOR ALL
2001VUCIDS-DEU B-NORM-AFT194RHC08
4. Procedure
Subtask 26-10-00-740-050-A
DELETED
Subtask 26-10-00-740-050-B ** ON A/C NOT FOR ALL
A. Test of the Ground Scanning of the CIDS-SDF
   (1) Do this test for CIDS-SDF1:
ACTION
RESULT
1.In the cockpit, on the Multipurpose Control and Display Unit (MCDU):
In the cockpit, on the MCDU:
  • Push the SMOKE line select key.
  • CIDS-SDF1 main menu comes into view.
2.On the MCDU:
On the MCDU:
  • Push the GND SCANNING select key.
  • CIDS-SDF1 GROUND SCANNING menu page comes into view.
  • Wait for approximately 3 minutes.
  • After approximately 3 minutes, the message NO FAULT DETECTED is shown.
3.On the MCDU:
On the MCDU:
  • Push the RETURN line select key until the SYSTEM REPORT/TEST FIRE PROT menu page comes into view.
  • The SYSTEM REPORT/TEST FIRE PROT menu page comes into view.
   (2) Do this test for CIDS-SDF2:
ACTION
RESULT
1.In the cockpit, on circuit-breaker panels 49VU and 122VU:
In the cockpit, on the MCDU:
Open, safety and tag this(these) circuit breaker(s):
  • 15WH on panel 49VU
  • 17WH on panel 122VU.
NOTE: It is recommended that you open circuit breaker 15WH before you open circuit breaker 17WH to get the correct messages on CIDS-SDF 2 GROUND SCANNING menu page.
NOTE: It is recommended that you wait for 10 seconds after you open the circuit breakers.
  • CIDS-SDF1 is de-energized.
2.In the cockpit, on the MCDU:
In the cockpit, on the MCDU:
  • Push the SMOKE line select key.
  • CIDS-SDF 2 main menu comes into view.
3.On the MCDU:
On the MCDU:
  • Push the GND SCANNING select key.
  • CIDS-SDF 2 GROUND SCANNING menu page comes into view.

  • The message CIDS(101RH)-SDF1 28VDC1 SPLY is shown.
  • The message SDF2(102RH)-DIR1(101RH) is shown.
  • The message CIRCUIT BREAKER 15WH/WRG:CAN BUS A is shown.
4.On the MCDU:
On the MCDU:
  • Push the RETURN line select key until the SYSTEM REPORT/TEST FIRE PROT menu page comes into view.
  • The SYSTEM REPORT/TEST FIRE PROT menu page comes into view.
5.In the cockpit, on circuit breaker-panels 49VU and 122VU:
In the cockpit, on the MCDU:
Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
  • 15WH on panel 49VU
  • 17WH on panel 122VU.
  • CIDS-SDF1 is energized again.
Subtask 26-10-00-740-050-D ** ON A/C NOT FOR ALL
A. Test of the Ground Scanning of the CIDS-SDF
   (1) Do this test for CIDS-SDF1:
ACTION
RESULT
1.In the cockpit, on the Multipurpose Control and Display Unit (MCDU):
In the cockpit, on the MCDU:
  • Push the line key adjacent to the SMOKE indication.
  • The CIDS-SDF page comes into view and shows:
    SDF1
    SDF2.
On the MCDU:
On the MCDU:
  • Push the line key adjacent to SDF1 indication.
  • CIDS-SDF1 main menu comes into view.
2.On the MCDU:
On the MCDU:
  • Push the GND SCANNING select key.
  • CIDS-SDF1 GROUND SCANNING menu page comes into view.
  • Wait for approximately 3 minutes.
  • After approximately 3 minutes, the message NO FAULT DETECTED is shown.
3.On the MCDU:
On the MCDU:
  • Push the RETURN line select key until the SYSTEM REPORT/TEST FIRE PROT menu page comes into view.
  • The SYSTEM REPORT/TEST FIRE PROT menu page comes into view.
   (2) Do this test for CIDS-SDF2:
ACTION
RESULT
1.In the cockpit, on circuit-breaker panels 49VU and 122VU:
In the cockpit, on the MCDU:
Open, safety and tag this(these) circuit breaker(s):
  • 15WH on panel 49VU
  • 17WH on panel 122VU.
NOTE: It is recommended that you open circuit breaker 15WH before you open circuit breaker 17WH to get the correct messages on CIDS-SDF 2 GROUND SCANNING menu page.
NOTE: It is recommended that you wait for 10 seconds after you open the circuit breakers.

  • CIDS-SDF1 is de-energized.
2.On the MCDU:
On the MCDU:
  • Push the line key adjacent to the SMOKE indication.
  • The CIDS-SDF page comes into view and shows:
    SDF1
    SDF2.
On the MCDU:
On the MCDU:
  • Push the line key adjacent to SDF2 indication.
  • CIDS-SDF2 main menu comes into view.
3.On the MCDU:
On the MCDU:
  • Push the GND SCANNING select key.
  • CIDS-SDF2 GROUND SCANNING menu page comes into view.

  • The message CIDS(101RH)-SDF1 28VDC1 SPLY is shown.
  • The message SDF2(102RH)-DIR1(101RH) is shown.
  • The message CIRCUIT BREAKER 15WH/WRG:CAN BUS A is shown.
4.On the MCDU:
On the MCDU:
  • Push the RETURN line select key until the SYSTEM REPORT/TEST FIRE PROT menu page comes into view.
  • The SYSTEM REPORT/TEST FIRE PROT menu page comes into view.
5.In the cockpit, on circuit-breaker panels 49VU and 122VU:
In the cockpit, on the MCDU:
Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
  • 15WH on panel 49VU
  • 17WH on panel 122VU.
  • CIDS-SDF1 is energized again.
5. Close-up
Subtask 26-10-00-862-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Put the aircraft back to its initial configuration.
   (2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).