Check Pressure at Life Raft Pressure Gauge (If Configuration Includes Visible Gauge)
TASK 25-66-41-210-001-A
Check Pressure at Life Raft Pressure Gauge (If Configuration Includes Visible Gauge)
1. Reason for the Job
Refer to the MPD TASK: 256600-02
CHECK PRESSURE AT LIFE RAFT PRESSURE GAUGE (IF CONFIGURATION INCLUDES VISIBLE GAUGE)
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 25-66-41-861-050-A ** ON A/C NOT FOR ALL Subtask 25-66-41-010-051-A ** ON A/C NOT FOR ALL
Subtask 25-66-41-210-052-A ** ON A/C NOT FOR ALL
Subtask 25-66-41-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:41:42 UTC
Check Pressure at Life Raft Pressure Gauge (If Configuration Includes Visible Gauge)
1. Reason for the Job
Refer to the MPD TASK: 256600-02
CHECK PRESSURE AT LIFE RAFT PRESSURE GAUGE (IF CONFIGURATION INCLUDES VISIBLE GAUGE)
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-66-00-00 | FLOATATION AND SURVIVAL EQUIPMENT - DESCRIPTION AND OPERATION |
Subtask 25-66-41-861-050-A ** ON A/C NOT FOR ALL Subtask 25-66-41-010-051-A ** ON A/C NOT FOR ALL
B. Get Access
(1) For the location of the life raft(s), refer to Para. Component Location (Ref. AMM D/O 25-66-00-00).
(2) Remove the supplemental life raft(s) from the related compartment(s).
4. Procedure(1) For the location of the life raft(s), refer to Para. Component Location (Ref. AMM D/O 25-66-00-00).
(2) Remove the supplemental life raft(s) from the related compartment(s).
NOTE: The location of the supplemental life raft(s) is shown with placard(s), which is (are) installed on the outside of the related compartment(s).
Subtask 25-66-41-210-052-A ** ON A/C NOT FOR ALL
A. Visual Check Procedure
(1) Make sure that the pressure gage shows the correct pressure related to the temperature.
(2) For the table of pressure values related to different temperatures refer to the manufacturer's Component Maintenance Manual (CMMv) of the life raft.
5. Close-up(1) Make sure that the pressure gage shows the correct pressure related to the temperature.
(2) For the table of pressure values related to different temperatures refer to the manufacturer's Component Maintenance Manual (CMMv) of the life raft.
NOTE: To find the CMM reference, you can use the applicable P/N in the IPC. You can use the FIN in the task title to find the applicable P/N.
(3) If the indicated pressure is above or below the limits, replace the supplemental life raft. Subtask 25-66-41-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Put the supplemental life raft(s) in the related compartment(s).
(2) Make sure that the work area is clean and clear of tools and other items.
Subtask 25-66-41-862-050-A ** ON A/C NOT FOR ALL (1) Put the supplemental life raft(s) in the related compartment(s).
(2) Make sure that the work area is clean and clear of tools and other items.