Operational Test of the Power Drive Units
TASK 25-52-00-710-005-A
Operational Test of the Power Drive Units
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-52-00-010-063-A ** ON A/C NOT FOR ALL
Subtask 25-52-00-860-058-A ** ON A/C NOT FOR ALL
Subtask 25-52-00-410-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:37:52 UTC
Operational Test of the Power Drive Units
WARNING:
DO NOT TOUCH THE POWER DRIVE UNIT:
1. Reason for the Job- UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S)
- DURING OPERATION TO PREVENT INJURY FROM PARTS THAT TURN.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 25-52-00-010-063-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Open the forward and/or aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) in position at the opening of the forward and/or aft cargo-compartment door(s).
(3) Put the WARNING NOTICE(S) on the control panel of the related cargo loading system to tell persons not to use it.
Subtask 25-52-00-865-110-A ** ON A/C NOT FOR ALL (1) Open the forward and/or aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) in position at the opening of the forward and/or aft cargo-compartment door(s).
(3) Put the WARNING NOTICE(S) on the control panel of the related cargo loading system to tell persons not to use it.
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | SEMI AUTO CLS-FWD | 3MY | E08 |
| 2000VU | SEMI AUTO CLS-FWD | 2MY | E06 |
| 2001VU | SEMI AUTO CLS-AFT | 103MY | D08 |
| 2001VU | SEMI AUTO CLS-AFT | 102MY | D06 |
Subtask 25-52-00-860-058-A ** ON A/C NOT FOR ALL
A. Preparation for the Operational Test
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
(2) Lower all the latch elements of the latches which have a proximity switch below them.
(3) Lower the YZ-latch on each door sill latch.
Subtask 25-52-00-865-111-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
(2) Lower all the latch elements of the latches which have a proximity switch below them.
(3) Lower the YZ-latch on each door sill latch.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 25-52-00-710-058-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | SEMI AUTO CLS-FWD | 3MY | E08 |
| 2000VU | SEMI AUTO CLS-FWD | 2MY | E06 |
| 2001VU | SEMI AUTO CLS-AFT | 103MY | D08 |
| 2001VU | SEMI AUTO CLS-AFT | 102MY | D06 |
C. Test
(1) Do the test of the power drive units in the forward and aft cargo compartments:
5. Close-up(1) Do the test of the power drive units in the forward and aft cargo compartments:
| ACTION | RESULT |
|---|---|
| For the forward cargo compartment: | |
| 1.On the control panel 2020VU1: | In the cargo compartment: |
|
|
| 2.On the control panel 2020VU1: | In the ball mat area: |
|
|
|
|
|
|
|
|
| 3.On the control panel 2020VU1: | On the cargo compartment floor: |
|
|
|
|
|
|
|
|
| 4.On the control panel 2020VU1: | On the control panel 2020VU1: |
|
|
| 5.On the control panel 2020VU2: | In the cargo compartment: |
|
|
| 6.On the control panel 2020VU2: | In the ball mat area: |
|
|
|
|
|
|
|
|
| 7.On the control panel 2020VU2: | On the cargo compartment floor: |
|
|
|
|
|
|
|
|
| 8.On the control panel 2020VU2: | On the control panel 2020VU2: |
|
|
Subtask 25-52-00-410-057-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Lift the YZ-latch on each door sill latch.
(3) Remove the WARNING NOTICE(S).
(4) Close the forward and/or aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
Subtask 25-52-00-862-053-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Lift the YZ-latch on each door sill latch.
(3) Remove the WARNING NOTICE(S).
(4) Close the forward and/or aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).