Operational Test of the Razor Supply System
TASK 25-44-00-710-001-A
Operational Test of the Razor Supply System
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-44-00-861-050-A Subtask 25-44-00-865-052-A
Subtask 25-44-00-710-050-A
Subtask 25-44-00-862-050-A
[Rev.10 from 2021]
2026.03.31 23:35:35 UTC
Operational Test of the Razor Supply System
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | MULTIMETER - STANDARD |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 25-44-00-861-050-A Subtask 25-44-00-865-052-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 2000VU | LIGHT-LAV | 1LQ | J01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | LAV SHAVER SOCKET | 1MT | B01 |
Subtask 25-44-00-710-050-A
A. Operational Test of the Razor Supply System
(1) Do the test of the razor supply system:
(2) Disconnect the multimeter from the razor outlets.
5. Close-up(1) Do the test of the razor supply system:
NOTE: The test is the same for all lavatories.
| ACTION | RESULT |
|---|---|
| In the related lavatory: -Connect the MULTIMETER - STANDARD to the razor outlets. | At the razor outlets: - The multimeter shows 110/220+15-5 VAC, 60Hz. |
Subtask 25-44-00-862-050-A