Removal of the Heated Floor Panels at Door 1


TASK 25-27-51-000-002-A
Removal of the Heated Floor Panels at Door 1


FIN: 30DS ** ON A/C NOT FOR ALL
FIN: 31DS ** ON A/C NOT FOR ALL
FIN: 32DS ** ON A/C NOT FOR ALL
FIN: 33DS ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
SCRAPER - NON METALLIC
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 25-28-42-010-001-A
Remove the Floor Covering above the Heated Floor Panels
TASK 52-10-00-010-001-A
Opening of the Passenger/Crew Door
3. Job Set-up
Subtask 25-27-51-861-051-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-27-51-010-052-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the forward passenger/crew door (Ref. AMM TASK 52-10-00-010-001).
   (2) Remove the Non-Textile Floor Covering (NTF) (Ref. AMM TASK 25-28-42-010-001).
Subtask 25-27-51-865-059-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUDOOR AREA HTG PANELS-CTL54DSA07
2000VUDR AREA HTG PNLS-DR1-FPH-RH52DSA06
2000VUDR AREA HTG PNLS-DR1-FPH-LH51DSA05
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PNLS-CTL3DSF08
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PNLS-DOOR1-FPH-RH52DSF06
2000VUDR AREA HTG PNLS-DOOR1-FPH LH51DSF05
4. Procedure
Subtask 25-27-51-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Heated Floor Panels
   (1) Remove the placards from the floor panels, if necessary (Ref. AMM D/O 11-32-25-00).
   (2) Find the end of the ligature cord (Ref. detail B and C, MAT. NO. 19-008) and pull the sealant out of the gap between the floor panel (2) and the floor structure.
   (3) Remove the heated floor panel assembly.
     (a) Remove the screws (1).
     (b) Carefully lift the floor panel (2) until you get access to the electrical connector (3).
     (c) Disconnect the electrical connector (3).
     (d) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (e) Disconnect the bonding strap (5):
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
     (f) Remove the screw (7), the washer (6) and the bonding strap (5).
     (g) Remove the floor panel (2).
   (4) Remove the sealants from the floor panel (2) and the floor structure with a SCRAPER - NON METALLIC.