Removal of the Heated Floor Panels at the Emergency Exit Doors
TASK 25-27-51-000-001-A
Removal of the Heated Floor Panels at the Emergency Exit Doors
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-27-51-861-050-A ** ON A/C NOT FOR ALL Subtask 25-27-51-010-050-A ** ON A/C NOT FOR ALL
Subtask 25-27-51-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:33:07 UTC
Removal of the Heated Floor Panels at the Emergency Exit Doors
FIN: 15DS ** ON A/C NOT FOR ALL
FIN: 16DS ** ON A/C NOT FOR ALL
FIN: 5DS ** ON A/C NOT FOR ALL
FIN: 6DS ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 16DS ** ON A/C NOT FOR ALL
FIN: 5DS ** ON A/C NOT FOR ALL
FIN: 6DS ** ON A/C NOT FOR ALL
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | SCRAPER - NON METALLIC |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 251DG, 252DG | |
| FOR [15DS] (FLOOR PANEL-HEAT.,DOOR AREA) | |
| FOR [16DS] (FLOOR PANEL-HEAT.,DOOR AREA) | |
| 251DG, 252DG | |
| FOR [5DS] (FLOOR PANEL-HEAT.,DOOR AREA) | |
| FOR [6DS] (FLOOR PANEL-HEAT.,DOOR AREA) | |
| 231GX, 231KX, 232GX, 232KX | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-22-00-010-002-A | Opening of the Emergency Exit Doors from the Outside |
| TASK 53-32-12-000-002-A | Removal of the Cabin Floor Panels |
| FOR [15DS] (FLOOR PANEL-HEAT.,DOOR AREA) | |
| FOR [16DS] (FLOOR PANEL-HEAT.,DOOR AREA) | |
| TASK 53-32-12-000-002-A | Removal of the Cabin Floor Panels |
| FOR [5DS] (FLOOR PANEL-HEAT.,DOOR AREA) | |
| FOR [6DS] (FLOOR PANEL-HEAT.,DOOR AREA) | |
| TASK 25-23-47-000-004-A | Removal of the Door Frame Linings of the LH FWD Emergency Exit Door, zone 231 |
| TASK 25-23-47-000-009-A | Removal of the Door Frame Linings of the Right Forward Emergency Exit Door from Zone 232 |
Subtask 25-27-51-861-050-A ** ON A/C NOT FOR ALL Subtask 25-27-51-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position adjacent to the emergency exit.
(2) Open the emergency exit door from the outside (Ref. AMM TASK 52-22-00-010-002).
(3) FOR [5DS] (FLOOR PANEL-HEAT.,DOOR AREA), [6DS] (FLOOR PANEL-HEAT.,DOOR AREA)
(a) Remove the door frame linings 231GX 231KX (Ref. AMM TASK 25-23-47-000-004) or 232GX 232KX (Ref. AMM TASK 25-23-47-000-009) as required.
(4) FOR [15DS] (FLOOR PANEL-HEAT.,DOOR AREA), [16DS] (FLOOR PANEL-HEAT.,DOOR AREA)
(a) Remove the floor panel 251DG or 252DG as required (Ref. AMM TASK 53-32-12-000-002).
Subtask 25-27-51-010-050-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT) in position adjacent to the emergency exit.
(2) Open the emergency exit door from the outside (Ref. AMM TASK 52-22-00-010-002).
(3) FOR [5DS] (FLOOR PANEL-HEAT.,DOOR AREA), [6DS] (FLOOR PANEL-HEAT.,DOOR AREA)
(a) Remove the door frame linings 231GX 231KX (Ref. AMM TASK 25-23-47-000-004) or 232GX 232KX (Ref. AMM TASK 25-23-47-000-009) as required.
(4) FOR [15DS] (FLOOR PANEL-HEAT.,DOOR AREA), [16DS] (FLOOR PANEL-HEAT.,DOOR AREA)
(a) Remove the floor panel 251DG or 252DG as required (Ref. AMM TASK 53-32-12-000-002).
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position adjacent to the emergency exit.
(2) Open the emergency exit door from the outside (Ref. AMM TASK 52-22-00-010-002).
(3) Remove the floor panel 251DG or 252DG as required (Ref. AMM TASK 53-32-12-000-002).
Subtask 25-27-51-865-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT) in position adjacent to the emergency exit.
(2) Open the emergency exit door from the outside (Ref. AMM TASK 52-22-00-010-002).
(3) Remove the floor panel 251DG or 252DG as required (Ref. AMM TASK 53-32-12-000-002).
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DR AREA HTG PNLS-CTL | 3DS | F08 |
| 2000VU | DR AREA HTG PANELS-DR2-FPH | 1DS | F07 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DR AREA HTG PANELS-DR2-HTR | 1DS | A08 |
| 2000VU | DR AREA HTG PANELS-DR2-CTL | 3DS | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | DOOR AREA HTG PNL-DOOR3-HTR | 11DS | F05 |
| 2001VU | DR AREA HTG PNLS-DOOR 3-CTL | 13DS | F03 |
Subtask 25-27-51-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the heated floor panel 5DS (6DS), 15DS (16DS)
(1) Remove the inner cover plate screws (1).
(2) Remove the inner cover plate (13).
(3) Pull the cord (10) up to remove the sealant from between the heated floor panel (4) and the floor.
(4) Remove the sealant from around the outer cover plate (3) with a SCRAPER - NON METALLIC.
(5) Remove the outer cover plate screws (1) and (2).
(6) Remove the outer cover plate (3).
(7) FOR [5DS] (FLOOR PANEL-HEAT.,DOOR AREA), [6DS] (FLOOR PANEL-HEAT.,DOOR AREA)
(a) Carefully lift up and support the heated floor panel (4) to get access to the electrical connections installed on the floor structure below the heated floor panel.
(8) FOR [15DS] (FLOOR PANEL-HEAT.,DOOR AREA), [16DS] (FLOOR PANEL-HEAT.,DOOR AREA)
(a) Get access to the electrical connections installed on the floor structure below the heated floor panel through the removed floor panels 251DG or 252DG.
(9) Remove the bolt (7), the washer (6) and the bonding strap (5).
(10) Disconnect the electrical connector (8).
(11) Remove the heated floor panel (4).
(12) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Subtask 25-27-51-020-050-B ** ON A/C NOT FOR ALL (1) Remove the inner cover plate screws (1).
(2) Remove the inner cover plate (13).
(3) Pull the cord (10) up to remove the sealant from between the heated floor panel (4) and the floor.
(4) Remove the sealant from around the outer cover plate (3) with a SCRAPER - NON METALLIC.
(5) Remove the outer cover plate screws (1) and (2).
(6) Remove the outer cover plate (3).
(7) FOR [5DS] (FLOOR PANEL-HEAT.,DOOR AREA), [6DS] (FLOOR PANEL-HEAT.,DOOR AREA)
(a) Carefully lift up and support the heated floor panel (4) to get access to the electrical connections installed on the floor structure below the heated floor panel.
(8) FOR [15DS] (FLOOR PANEL-HEAT.,DOOR AREA), [16DS] (FLOOR PANEL-HEAT.,DOOR AREA)
(a) Get access to the electrical connections installed on the floor structure below the heated floor panel through the removed floor panels 251DG or 252DG.
(9) Remove the bolt (7), the washer (6) and the bonding strap (5).
(10) Disconnect the electrical connector (8).
(11) Remove the heated floor panel (4).
(12) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
A. Removal of the Heated Floor Panel 15DS and 16DS
(1) Remove the screws (1) and the plate (9).
(2) Pull the cord (7) and remove the sealant (8).
(3) Remove the sealant from the plate (4) with a SCRAPER - NON METALLIC.
(4) Remove the screws (1) and (3) and the plate (4).
(5) Get access to the electrical connections installed on the floor structure below the heated floor panel through the removed floor panels.
(6) Disconnect the electrical connector (13).
(7) Put a CAP - BLANKING on each disconnected electrical connector.
(9) Remove the heated floor panel (5).
(1) Remove the screws (1) and the plate (9).
(2) Pull the cord (7) and remove the sealant (8).
(3) Remove the sealant from the plate (4) with a SCRAPER - NON METALLIC.
(4) Remove the screws (1) and (3) and the plate (4).
(5) Get access to the electrical connections installed on the floor structure below the heated floor panel through the removed floor panels.
(6) Disconnect the electrical connector (13).
(7) Put a CAP - BLANKING on each disconnected electrical connector.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
(8) Remove the screw (12), the washer (11) and the bonding strap (10). (9) Remove the heated floor panel (5).
Heated Floor Panel 5DS (6DS), 15DS (16DS)