Installation of the Control Unit
TASK 25-27-34-400-002-A
Installation of the Control Unit
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 25-27-34-860-051-A ** ON A/C NOT FOR ALL
Subtask 25-27-34-420-052-A ** ON A/C NOT FOR ALL
Subtask 25-27-34-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:32:59 UTC
Installation of the Control Unit
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 2 | STEPLADDER 2.0 M (6.6 FT) |
| No specific | Torque wrench: range to between 8.8 and 5.3 lbf.in (0.10 and 0.06 m.daN ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-27-00-740-001-A | Bite Test of the Heated Floor Panel System |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 25-27-34-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the avionics compartment door 811 (Ref. AMM TASK 52-41-00-010-002) is open.
(3) Make sure that the STEPLADDER 2.0 M (6.6 FT) is in position.
Subtask 25-27-34-865-057-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the avionics compartment door 811 (Ref. AMM TASK 52-41-00-010-002) is open.
(3) Make sure that the STEPLADDER 2.0 M (6.6 FT) is in position.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DOOR AREA HTG PANELS-CTL | 54DS | A07 |
| 2000VU | DR AREA HTG PNLS-DR1-FPH-RH | 52DS | A06 |
| 2000VU | DR AREA HTG PNLS-DR1-FPH-LH | 51DS | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DR AREA HTG PNLS-DOOR1-FPH-RH | 52DS | F06 |
| 2000VU | DR AREA HTG PNLS-DOOR1-FPH LH | 51DS | F05 |
Subtask 25-27-34-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the Control Unit 60DS, 66DS.
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Carefully move the control unit (6) on the adapter assembly (7).
(b) Make sure that all the electrical connections are clean and in the correct condition.
(c) Connect the electrical connector (1) with the spring latches (3).
(d) Connect the electrical connector (2) with the screws (4).
1 TORQUE the screws (4) to between 8.8 and 5.3 lbf.in (0.10 and 0.06 m.daN )
.
Subtask 25-27-34-865-058-A ** ON A/C NOT FOR ALL NOTE: The procedure for the control units are the same.
(1) Make sure that the parts retained from the removed component are clean and in the correct condition.(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Carefully move the control unit (6) on the adapter assembly (7).
NOTE: Make sure that the locking catch (5) holds the control unit (6) in position.
(5) Connect the Electrical Connections: CAUTION:
MAKE SURE THAT THE SPRING LATCHES CORRECTLY HOLD THE CONNECTOR IN THE FULLY ENGAGED POSITION. THE SPRING LATCHES PREVENT UNWANTED MOVEMENT OF THE CONNECTOR, AND THUS THE RISK OF ARCING, WHICH CAN CAUSE DAMAGE TO THE UNIT.
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.(b) Make sure that all the electrical connections are clean and in the correct condition.
(c) Connect the electrical connector (1) with the spring latches (3).
(d) Connect the electrical connector (2) with the screws (4).
1 TORQUE the screws (4) to between 8.8 and 5.3 lbf.in (0.10 and 0.06 m.daN )
. B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 25-27-34-740-052-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DOOR AREA HTG PANELS-CTL | 54DS | A07 |
| 2000VU | DR AREA HTG PNLS-DR1-FPH-RH | 52DS | A06 |
| 2000VU | DR AREA HTG PNLS-DR1-FPH-LH | 51DS | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DR AREA HTG PNLS-DOOR1-FPH-RH | 52DS | F06 |
| 2000VU | DR AREA HTG PNLS-DOOR1-FPH LH | 51DS | F05 |
Subtask 25-27-34-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access to the avionics compartment:
(a) Close the avionics compartment door 811 (Ref. AMM TASK 52-41-00-410-002).
(b) Remove the STEPLADDER 2.0 M (6.6 FT).
Subtask 25-27-34-862-051-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access to the avionics compartment:
(a) Close the avionics compartment door 811 (Ref. AMM TASK 52-41-00-410-002).
(b) Remove the STEPLADDER 2.0 M (6.6 FT).
Control Unit 60DS, 66DS