Bite Test of the Heated Floor Panel System


TASK 25-27-00-740-001-A
Bite Test of the Heated Floor Panel System


FIN: 14DS ** ON A/C NOT FOR ALL
FIN: 4DS ** ON A/C NOT FOR ALL
FIN: 60DS ** ON A/C NOT FOR ALL
FIN: 66DS ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [14DS] (CTL UNIT-DOOR AREA HEATING)
152FW
FOR [4DS] (CTL UNIT-DOOR AREA HEATING)
132JW
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
FOR [14DS] (CTL UNIT-DOOR AREA HEATING)
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
FOR [4DS] (CTL UNIT-DOOR AREA HEATING)
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
FOR [60DS] (CTL UNIT-DOOR AREA HEATING)
FOR [66DS] (CTL UNIT-DOOR AREA HEATING)
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 25-27-00-861-051-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 25-27-00-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) FOR [4DS] (CTL UNIT-DOOR AREA HEATING)
     (a) Open the FWD cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
     (b) Set the CARGO COMPT light switch 6LU to ON.
     (c) Remove the sidewall lining 132JW.
   (2) FOR [14DS] (CTL UNIT-DOOR AREA HEATING)
     (a) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
     (b) Set the CARGO COMPT light switch 8LU to ON.
     (c) Remove the sidewall lining 152FW.
Subtask 25-27-00-010-050-B ** ON A/C NOT FOR ALL
B. Get Access
   (1) FOR [14DS] (CTL UNIT-DOOR AREA HEATING)
     (a) Open the aft cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
     (b) Set the CARGO COMPT light switch 8LU to ON.
     (c) Remove the sidewall lining 152FW.
Subtask 25-27-00-010-052-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) FOR [60DS] (CTL UNIT-DOOR AREA HEATING), [66DS] (CTL UNIT-DOOR AREA HEATING)
     (a) In the cockpit on the panel 50VU:
  • Push the P/B SW-AVIONICS/COMPT LT (23LS).
     (b) Open the avionics compartment door 811 (Ref. AMM TASK 52-41-00-010-002).
Subtask 25-27-00-010-052-B ** ON A/C NOT FOR ALL
C. Get Access
   (1) FOR [60DS] (CTL UNIT-DOOR AREA HEATING), [66DS] (CTL UNIT-DOOR AREA HEATING)
     (a) In the cockpit on the panel 50VU:
  • Push the P/B SW-AVIONICS/COMPT LT (23LS).
     (b) If applicable, push the ON/OFF touch button on the flight attendant panel in ON position.
     (c) Open the avionics compartment door 811 (Ref. AMM TASK 52-41-00-010-002).
Subtask 25-27-00-865-058-A ** ON A/C NOT FOR ALL
D. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUELEC/GALLEY/CNTOR7MCS28
** ON A/C NOT FOR ALL
2000VUDOOR AREA HTG PANELS-CTL54DSA07
2000VUDR AREA HTG PNLS-DR1-FPH-RH52DSA06
2000VUDR AREA HTG PNLS-DR1-FPH-LH51DSA05
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PNLS-CTL3DSF08
2000VUDR AREA HTG PANELS-DR2-FPH1DSF07
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PNLS-DOOR1-FPH-RH52DSF06
2000VUDR AREA HTG PNLS-DOOR1-FPH LH51DSF05
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PANELS-DR2-HTR1DSA08
2000VUDR AREA HTG PANELS-DR2-CTL3DSA06
** ON A/C NOT FOR ALL
2001VUDOOR AREA HTG PNL-DOOR3-HTR11DSF05
2001VUDR AREA HTG PNLS-DOOR 3-CTL13DSF03
4. Procedure
Subtask 25-27-00-740-050-A ** ON A/C NOT FOR ALL
A. Do this test:
ACTION
RESULT
1.On the related control unit:
  • Push and hold the pushbutton HEATER TEST.
On the related control unit:
  • The indicators come on.
2.Release the pushbutton HEATER TEST.
The indicators go off.
5. Close-up
Subtask 25-27-00-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Put all CB and switches to the initial configuration.
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) FOR [4DS] (CTL UNIT-DOOR AREA HEATING)
     (a) Install the sidewall lining 132JW.
     (b) Set the CARGO COMPT light switch 6LU to OFF.
     (c) Close the FWD cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
   (4) FOR [14DS] (CTL UNIT-DOOR AREA HEATING)
     (a) Install the sidewall lining 152FW.
     (b) Set the CARGO COMPT light switch 8LU to OFF.
     (c) Close the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
Subtask 25-27-00-410-050-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Put all CB and switches to the initial configuration.
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) FOR [14DS] (CTL UNIT-DOOR AREA HEATING)
     (a) Install the sidewall lining 152FW.
     (b) Set the CARGO COMPT light switch 8LU to OFF.
     (c) Close the aft cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
Subtask 25-27-00-410-052-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) FOR [60DS] (CTL UNIT-DOOR AREA HEATING), [66DS] (CTL UNIT-DOOR AREA HEATING)
     (a) Put all CB and switches to the initial configuration.
     (b) Make sure that the work area is clean and clear of tools and other items.
     (c) Close the avionics compartment door 811 (Ref. AMM TASK 52-41-00-410-002).
     (d) In the cockpit on the panel 50VU:
  • Push the P/B SW-AVIONICS/COMPT LT (23LS).
Subtask 25-27-00-410-052-B ** ON A/C NOT FOR ALL
B. Close Access
   (1) FOR [60DS] (CTL UNIT-DOOR AREA HEATING), [66DS] (CTL UNIT-DOOR AREA HEATING)
     (a) If applicable, put the ON/OFF touch button on the flight attendant panel in OFF position.
     (b) Make sure that the work area is clean and clear of tools and other items.
     (c) Close the avionics compartment door 811 (Ref. AMM TASK 52-41-00-410-002).
     (d) In the cockpit on the panel 50VU:
  • Push the P/B SW-AVIONICS/COMPT LT (23LS).
Subtask 25-27-00-862-051-A ** ON A/C NOT FOR ALL
C. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).