Reactivation of the Heated Floor Panels
TASK 25-27-00-440-801-A
Reactivation of the Heated Floor Panels
MMEL 25-27-42A
HEATING FUNCTION OF HEATED FLOOR PANELS (PASSENGER/CREW DOORS, EMERGENCY EXITS, AND GALLEY AREAS) (FAA ONLY)
(FAA Reference: MMEL 252701)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-27-00-861-054-A ** ON A/C NOT FOR ALL 4. Procedure
Subtask 25-27-00-865-063-A ** ON A/C NOT FOR ALL
Subtask 25-27-00-862-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:32:50 UTC
Reactivation of the Heated Floor Panels
ZONE: 100
ZONE: 200
FIN: 15DS ** ON A/C NOT FOR ALL
FIN: 16DS ** ON A/C NOT FOR ALL
FIN: 30DS ** ON A/C NOT FOR ALL
FIN: 31DS ** ON A/C NOT FOR ALL
FIN: 32DS ** ON A/C NOT FOR ALL
FIN: 33DS ** ON A/C NOT FOR ALL
FIN: 5DS ** ON A/C NOT FOR ALL
FIN: 6DS ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 200
FIN: 15DS ** ON A/C NOT FOR ALL
FIN: 16DS ** ON A/C NOT FOR ALL
FIN: 30DS ** ON A/C NOT FOR ALL
FIN: 31DS ** ON A/C NOT FOR ALL
FIN: 32DS ** ON A/C NOT FOR ALL
FIN: 33DS ** ON A/C NOT FOR ALL
FIN: 5DS ** ON A/C NOT FOR ALL
FIN: 6DS ** ON A/C NOT FOR ALL
MMEL 25-27-42A
HEATING FUNCTION OF HEATED FLOOR PANELS (PASSENGER/CREW DOORS, EMERGENCY EXITS, AND GALLEY AREAS) (FAA ONLY)
(FAA Reference: MMEL 252701)
NOTE: This reactivation task is not related to an AFM-CML/MMEL item for all aircraft under EASA or CAAC regulation.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 100 | LOWER HALF FUSELAGE INCLUDING RADOME |
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 25-27-00-861-054-A ** ON A/C NOT FOR ALL 4. Procedure
Subtask 25-27-00-865-063-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 25-27-00-440-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DOOR AREA HTG PANELS-CTL | 54DS | A07 |
| 2000VU | DR AREA HTG PNLS-DR1-FPH-RH | 52DS | A06 |
| 2000VU | DR AREA HTG PNLS-DR1-FPH-LH | 51DS | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DR AREA HTG PNLS-CTL | 3DS | F08 |
| 2000VU | DR AREA HTG PANELS-DR2-FPH | 1DS | F07 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DR AREA HTG PNLS-DOOR1-FPH-RH | 52DS | F06 |
| 2000VU | DR AREA HTG PNLS-DOOR1-FPH LH | 51DS | F05 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DR AREA HTG PANELS-DR2-HTR | 1DS | A08 |
| 2000VU | DR AREA HTG PANELS-DR2-CTL | 3DS | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | DOOR AREA HTG PNL-DOOR3-HTR | 11DS | F05 |
| 2001VU | DR AREA HTG PNLS-DOOR 3-CTL | 13DS | F03 |
B. Reactivation of the Heated Floor Panels of Door 1
(1) Remove the blanking cap from the related fuse socket and install a serviceable fuse:
Subtask 25-27-00-440-051-A ** ON A/C NOT FOR ALL (1) Remove the blanking cap from the related fuse socket and install a serviceable fuse:
- HFP 30DS (RH-A) / Control Unit 66DS - Heater 1
- HFP 31DS (LH-A) / Control Unit 60DS - Heater 1
- HFP 32DS (RH-B) / Control Unit 66DS - Heater 2
- HFP 33DS (LH-B) / Control Unit 60DS - Heater 2
C. Reactivation of the Heated Floor Panels at the Emergncy Exit Doors
(1) Remove the blanking cap from the related fuse socket and install a serviceable fuse:
(a) For Door 2 Area:
Subtask 25-27-00-440-051-B ** ON A/C NOT FOR ALL (1) Remove the blanking cap from the related fuse socket and install a serviceable fuse:
(a) For Door 2 Area:
- HFP 5DS (LH) / Control Unit 4DS - Heater 1
- HFP 6DS (RH) / Control Unit 4DS - Heater 2
- HFP 15DS (LH) / Control Unit 14DS - Heater 1
- HFP 16DS (RH) / Control Unit 14DS - Heater 2
C. Reactivation of the Heated Floor Panels at the Emergncy Exit Doors
(1) Remove the blanking cap from the related fuse socket and install a serviceable fuse:
Subtask 25-27-00-865-061-A ** ON A/C NOT FOR ALL (1) Remove the blanking cap from the related fuse socket and install a serviceable fuse:
- HFP 15DS (LH) / Control Unit 14DS - Heater 1
- HFP 16DS (RH) / Control Unit 14DS - Heater 2
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 25-27-00-860-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DOOR AREA HTG PANELS-CTL | 54DS | A07 |
| 2000VU | DR AREA HTG PNLS-DR1-FPH-RH | 52DS | A06 |
| 2000VU | DR AREA HTG PNLS-DR1-FPH-LH | 51DS | A05 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DR AREA HTG PNLS-CTL | 3DS | F08 |
| 2000VU | DR AREA HTG PANELS-DR2-FPH | 1DS | F07 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DR AREA HTG PNLS-DOOR1-FPH-RH | 52DS | F06 |
| 2000VU | DR AREA HTG PNLS-DOOR1-FPH LH | 51DS | F05 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DR AREA HTG PANELS-DR2-HTR | 1DS | A08 |
| 2000VU | DR AREA HTG PANELS-DR2-CTL | 3DS | A06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | DOOR AREA HTG PNL-DOOR3-HTR | 11DS | F05 |
| 2001VU | DR AREA HTG PNLS-DOOR 3-CTL | 13DS | F03 |
E. Put the aircraft back to the serviceable condition.
(1) Close the related item(s) in the logbook.
5. Close-up(1) Close the related item(s) in the logbook.
Subtask 25-27-00-862-054-A ** ON A/C NOT FOR ALL