Deactivation of the Heated Floor Panels (HFP)


TASK 25-27-00-040-801-A
Deactivation of the Heated Floor Panels (HFP)


ZONE: 100
ZONE: 200
FIN: 15DS ** ON A/C NOT FOR ALL
FIN: 16DS ** ON A/C NOT FOR ALL
FIN: 30DS ** ON A/C NOT FOR ALL
FIN: 31DS ** ON A/C NOT FOR ALL
FIN: 32DS ** ON A/C NOT FOR ALL
FIN: 33DS ** ON A/C NOT FOR ALL
FIN: 5DS ** ON A/C NOT FOR ALL
FIN: 6DS ** ON A/C NOT FOR ALL
1. Reason for the Job
This procedure tells you how to manually isolate a defective HFP.
To do this procedure, refer to the FAA Reference: MMEL TASK: 252701 - Heating Function of HFPs (Passenger/Crew Doors, Emergency Exits and Galley Areas) (FAA only).
NOTE: This deactivation task is not related to an AFM-CDL/MMEL item for all aircraft under EASA or CAAC regulation.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
100
LOWER HALF FUSELAGE INCLUDING RADOME
200
UPPER HALF FUSELAGE
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 25-27-00-00
ANCILLARY EQUIPMENT - DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 25-27-00-861-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-41-00-861-002).
   (2) For the location of this component, refer to Para. Component Location (Ref. AMM D/O 25-27-00-00).
4. Procedure
Subtask 25-27-00-865-060-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUDOOR AREA HTG PANELS-CTL54DSA07
2000VUDR AREA HTG PNLS-DR1-FPH-RH52DSA06
2000VUDR AREA HTG PNLS-DR1-FPH-LH51DSA05
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PNLS-CTL3DSF08
2000VUDR AREA HTG PANELS-DR2-FPH1DSF07
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PNLS-DOOR1-FPH-RH52DSF06
2000VUDR AREA HTG PNLS-DOOR1-FPH LH51DSF05
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PANELS-DR2-HTR1DSA08
2000VUDR AREA HTG PANELS-DR2-CTL3DSA06
** ON A/C NOT FOR ALL
2001VUDOOR AREA HTG PNL-DOOR3-HTR11DSF05
2001VUDR AREA HTG PNLS-DOOR 3-CTL13DSF03
Subtask 25-27-00-040-050-A ** ON A/C NOT FOR ALL
B. Deactivation of the HFP at Door 1
   (1) Remove the related fuse from the applicable control unit:
  • HFP 30DS (RH-A) / Control Unit 66DS - Heater 1
  • HFP 31DS (LH-A) / Control Unit 60DS - Heater 1
  • HFP 32DS (RH-B) / Control Unit 66DS - Heater 2
  • HFP 33DS (LH-B) / Control Unit 60DS - Heater 2.
   (2) Install a blanking cap on the related fuse socket.
   (3) Install a grey Inoperative (INOP) label adjacent to the related LED light/fuse on the control unit.
   (4) Make an entry in the logbook that the related HFP is isolated.
Subtask 25-27-00-040-051-A ** ON A/C NOT FOR ALL
C. Deactivation of the HFP at the Emergency Exit Doors
   (1) Remove the related fuse from the applicable control unit:
     (a) For Door 2 Area:
  • HFP 5DS (LH) / Control Unit 4DS - Heater 1
  • HFP 6DS (RH) / Control Unit 4DS - Heater 2.
     (b) For Door 3 Area:
  • HFP 15DS (LH) / Control Unit 14DS - Heater 1
  • HFP 16DS (RH) / Control Unit 14DS - Heater 2.
   (2) Install a blanking cap on the related fuse socket.
   (3) Install a grey Inoperative (INOP) label adjacent to the related LED light/fuse on the control unit.
   (4) Make an entry in the logbook that the related HFP is isolated.
Subtask 25-27-00-040-051-B ** ON A/C NOT FOR ALL
C. Deactivation of the HFP at the Emergency Exit Doors
   (1) Remove the related fuse from the applicable control unit:
  • HFP 15DS (LH) / Control Unit 14DS - Heater 1
  • HFP 16DS (RH) / Control Unit 14DS - Heater 2.
   (2) Install a blanking cap on the related fuse socket.
   (3) Install a grey Inoperative (INOP) label adjacent to the related LED light/fuse on the control unit.
   (4) Make an entry in the logbook that the related HFP is isolated.
Subtask 25-27-00-865-062-A ** ON A/C NOT FOR ALL
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUDOOR AREA HTG PANELS-CTL54DSA07
2000VUDR AREA HTG PNLS-DR1-FPH-RH52DSA06
2000VUDR AREA HTG PNLS-DR1-FPH-LH51DSA05
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PNLS-CTL3DSF08
2000VUDR AREA HTG PANELS-DR2-FPH1DSF07
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PNLS-DOOR1-FPH-RH52DSF06
2000VUDR AREA HTG PNLS-DOOR1-FPH LH51DSF05
** ON A/C NOT FOR ALL
2000VUDR AREA HTG PANELS-DR2-HTR1DSA08
2000VUDR AREA HTG PANELS-DR2-CTL3DSA06
** ON A/C NOT FOR ALL
2001VUDOOR AREA HTG PNL-DOOR3-HTR11DSF05
2001VUDR AREA HTG PNLS-DOOR 3-CTL13DSF03
5. Close-up
Subtask 25-27-00-862-053-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).