Cleaning of EWIS Installed in 49VU and 120VU (Only If Contaminated)(EWIS)
TASK 24-92-00-100-017-A
Cleaning of EWIS Installed in 49VU and 120VU (Only If Contaminated)(EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200211-02
CLEANING OF EWIS INSTALLED IN 49VU AND 120VU (ONLY IF CONTAMINATED) (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-92-00-862-106-A Subtask 24-92-00-010-118-A
Subtask 24-92-00-160-066-A
Subtask 24-92-00-410-116-A
[Rev.10 from 2021]
2026.04.02 06:13:25 UTC
Cleaning of EWIS Installed in 49VU and 120VU (Only If Contaminated)(EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200211-02
CLEANING OF EWIS INSTALLED IN 49VU AND 120VU (ONLY IF CONTAMINATED) (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 212 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-10-00-010-001-A | Opening of the Passenger/Crew Door |
| TASK 52-10-00-410-001-A | Closing of the Passenger/Crew Door |
| ESPM 2055000 | |
Subtask 24-92-00-862-106-A Subtask 24-92-00-010-118-A
B. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position.
(2) Open the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-010-001).
(3) Open the overhead circuit-breaker panel 49VU.
(4) On the rear panel 120VU, open:
4. Procedure(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position.
(2) Open the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-010-001).
(3) Open the overhead circuit-breaker panel 49VU.
(4) On the rear panel 120VU, open:
- The rear circuit-breaker panel 121VU
- The rear circuit-breaker panel 122VU
- The AC power center 123VU
- The AC power center 124VU
- The rear circuit-breaker panel 125VU.
Subtask 24-92-00-160-066-A
A. Cleaning of All Wiring Installed in 49VU and 120VU (Only Contaminated Wiring)
(1) Clean the wiring if there is dust or lint contamination ESPM 2055000.
(a) On the AC/DC feeder routes: 1G, 3G and 4G.
(b) On the AC/DC power-distribution routes: 1P, 2P and 6P.
(c) On the flight control wiring.
(d) On the engine control routes: 1S and 2S.
(e) On the other routes: 1M and 2M.
(f) On the audio route: 1R.
(g) On the generator excitation routes: 1E, 2E and 3E.
5. Close-up(1) Clean the wiring if there is dust or lint contamination ESPM 2055000.
(a) On the AC/DC feeder routes: 1G, 3G and 4G.
(b) On the AC/DC power-distribution routes: 1P, 2P and 6P.
(c) On the flight control wiring.
(d) On the engine control routes: 1S and 2S.
(e) On the other routes: 1M and 2M.
(f) On the audio route: 1R.
(g) On the generator excitation routes: 1E, 2E and 3E.
Subtask 24-92-00-410-116-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) On the rear panel 120VU, close:
(4) Close the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-410-001).
(5) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) On the rear panel 120VU, close:
- The rear circuit-breaker panel 121VU
- The rear circuit-breaker panel 122VU
- The AC power center 123VU
- The AC power center 124VU
- The rear circuit-breaker panel 125VU.
(4) Close the forward passenger/crew door 831 (841) (Ref. AMM TASK 52-10-00-410-001).
(5) Remove the access platform(s).
49VU and 120VU - Location