Installation of the Micro Contactor Located in the Panel 200VU
TASK 24-56-55-400-001-A
Installation of the Micro Contactor Located in the Panel 200VU
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 24-56-55-860-051-B
Subtask 24-56-55-420-050-A
Subtask 24-56-55-865-052-A
[Rev.10 from 2021]
2026.03.31 23:25:12 UTC
Installation of the Micro Contactor Located in the Panel 200VU
WARNING:
MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT ELECTRICAL CIRCUITS.
THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-23-41-400-001-A | Installation of the Ceiling Panels |
| TASK 25-23-42-400-001-A | Installation of the Ceiling Panels - Forward Utility Area |
Subtask 24-56-55-860-051-B
A. Safety Precautions
(1) On the overhead panel, on the ELEC section of panel 35VU:
(a) Make sure that the GALY & CAB pushbutton switch is released (the OFF legend is on).
(b) Make sure that the WARNING NOTICE(S) is (are) in posittion to tell persons not to operate the GALY & CAB pushbutton switch.
Subtask 24-56-55-865-051-A (1) On the overhead panel, on the ELEC section of panel 35VU:
(a) Make sure that the GALY & CAB pushbutton switch is released (the OFF legend is on).
(b) Make sure that the WARNING NOTICE(S) is (are) in posittion to tell persons not to operate the GALY & CAB pushbutton switch.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | ELEC/GALLEY/CNTOR | 7MC | S28 |
| 122VU | ELEC/GALY & CAB/CTL | 1XA | S26 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AFT GALLEY/FEEDER A | 3MC | AF04 |
| ** ON A/C ALL | |||
| 123VU | FWD GALLEY/FEEDER F | 16MC | AC10 |
| 123VU | AFT GALLEY/FEEDER E | 14MC | AF09 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AFT GALLEY/FEEDER B | 12MC | AD09 |
| 123VU | FWD GALLEY/FEEDER D | 2MC | AD04 |
| 123VU | FWD GALLEY/FEEDER C | 1MC | AE10 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | FWD GALLEY/FEEDER D | 2MC | AE02 |
Subtask 24-56-55-420-050-A
A. Installation of the Micro Contactor
(2) Install the nuts (1).
(3) Tighten the nuts (1).
(4) Install the power supply wires (2).
(5) Install the washers (3) and the screws (4).
(6) Tighten the screws (4).
(7) Connect the wires (5) to the contactor (6).
5. Close-upCAUTION:
REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES.
INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
(1) Put the contactor (6) in position. (2) Install the nuts (1).
(3) Tighten the nuts (1).
(4) Install the power supply wires (2).
(5) Install the washers (3) and the screws (4).
(6) Tighten the screws (4).
(7) Connect the wires (5) to the contactor (6).
Subtask 24-56-55-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 24-56-55-410-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | ELEC/GALLEY/CNTOR | 7MC | S28 |
| 122VU | ELEC/GALY & CAB/CTL | 1XA | S26 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AFT GALLEY/FEEDER A | 3MC | AF04 |
| ** ON A/C ALL | |||
| 123VU | FWD GALLEY/FEEDER F | 16MC | AC10 |
| 123VU | AFT GALLEY/FEEDER E | 14MC | AF09 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AFT GALLEY/FEEDER B | 12MC | AD09 |
| 123VU | FWD GALLEY/FEEDER D | 2MC | AD04 |
| 123VU | FWD GALLEY/FEEDER C | 1MC | AE10 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | FWD GALLEY/FEEDER D | 2MC | AE02 |
B. Installation of the Ceiling Panels
(1) Install the ceiling panels (Ref. AMM TASK 25-23-41-400-001).
(2) Install the forward utility-area ceiling-panels (Ref. AMM TASK 25-23-42-400-001).
Subtask 24-56-55-942-050-A (1) Install the ceiling panels (Ref. AMM TASK 25-23-41-400-001).
(2) Install the forward utility-area ceiling-panels (Ref. AMM TASK 25-23-42-400-001).
C. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
Micro Contactor Located in the Panel 200VU