W DOC AIRBUS | AMM A320F

Removal of the AC Shed Essential Bus Contactor


TASK 24-52-55-000-001-A
Removal of the AC Shed Essential Bus Contactor


ZONE: 125
FIN: 8XH
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
125
LATERAL AVIONIC COMPARTMENT
812, 822
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 24-52-55-010-050-A
A. Get access to the avionics compartment.
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the avionics compartment doors 812 and 822.
   (2) Open the access doors 812 and 822.
   (3) Open the access panels of the AC/DC emergency power center 106VU and the access panels of the BATTERY power center 105VU.
Subtask 24-52-55-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/CSM/G /EV AUTO/SPLY7XEC01
106VUCSM/G /EV/MAN/SPLY6XEB04
106VUAC/SHED/ESS BUS/CNTOR/CTL1XHC04
106VUESS TR/SPLY4PEC01
122VUELEC/CNTOR/ESS/DC BUS/TIE3PCW26
123VUAC ESS/BUS ON/BUS 11XCAC12
123VUAC ESS/BUS ON/BUS 22XCAC01
4. Procedure
Subtask 24-52-55-020-050-A
A. Removal of the Contactor
   (1) Loosen the 3 captive screws (1).
NOTE: Do not remove the captive screws (1) and the spring washers from the contactor (2).
   (2) Remove the contactor (2).
[Rev.10 from 2021] 2026.03.31 23:24:59 UTC