W DOC AIRBUS | AMM A320F

Removal of the Contactor


TASK 24-51-55-000-002-A
Removal of the Contactor


WARNING: MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT ELECTRICAL CIRCUITS. THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.
ZONE: 212
FIN: 27XN
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
212
COCKPIT
121AL
 C. Referenced Information
REFERENCE
DESIGNATION
F Contactor ** ON A/C NOT FOR ALL
F Contactor ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 24-51-55-010-051-A
A. Get Access
   (1) In the cockpit, remove the panel (6) which gives access to the panel 122VU. The panel 122VU is at the top of the panel 120VU.
   (2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position at the access door 121AL.
   (3) Open the access door 121AL.
Subtask 24-51-55-860-052-A
B. Safety Precautions
   (1) Make sure that the external power connector is not connected to the aircraft external power receptacle.
   (2) Put WARNING NOTICE(S) in position on the access door 121AL to tell persons not to connect the external power connector to the aircraft external power receptacle.
   (3) In the cockpit, on the ELEC panel 35VU, make sure that these pushbutton switches are released:
  • BAT 1, BAT 2.
  • APU GEN.
  • GEN 1, GEN 2.
  • EXT PWR.
   (4) In the cockpit, put a WARNING NOTICE(S) in position to tell persons not to operate the pushbutton switches on these overhead panels:
  • 21VU (EMER ELEC PWR section).
  • 25VU (APU section).
  • 35VU (ELEC).
Subtask 24-51-55-865-053-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUELEC/AC SHED BUS/CNTOR26XNU25
123VUSHED BUS/218XP/220XP SPLY28XNAC02
4. Procedure
Subtask 24-51-55-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Contactor
CAUTION: REMOVE THE CONTACTOR ONLY AND NOT THE BASE OR THE MODULE WHERE THE WIRES ARE CONNECTED.
   (1) Disconnect the electrical connector (4) from the electrical receptacle (5).
   (2) Put CAP - BLANKING on the disconnected electrical connector (4) and the electrical receptacle (5).
   (3) Loosen the six captive screws (2).
NOTE: Do not remove the captive screws (2) and the spring washers from the contactor (3).
   (4) Remove the contactor (3) from the contactor base (1).
Subtask 24-51-55-020-052-B ** ON A/C NOT FOR ALL
A. Removal of the Contactor
CAUTION: REMOVE THE CONTACTOR ONLY AND NOT THE BASE OR THE MODULE WHERE THE WIRES ARE CONNECTED.
   (1) Disconnect the electrical connector (4) from the electrical receptacle (5).
   (2) Put CAP - BLANKING on the disconnected electrical connector (4) and the electrical receptacle (5).
   (3) Loosen the six captive screws (2).
NOTE: Do not remove the captive screws (2) and the spring washers from the contactor (3).
   (4) Remove the contactor (3) from the module (1).
[Rev.10 from 2021] 2026.03.31 23:24:53 UTC