W DOC AIRBUS | AMM A320F

Reactivation of the Galley Supply System


TASK 24-51-00-440-001-A
Reactivation of the Galley Supply System


1. Reason for the Job
MMEL 24-26-02B
GALY & CAB MANUAL LOAD SHED SYSTEM (GALY & CAB PB-SW)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TSM 24-56-00-810-801
Galley Supply Fault
3. Job Set-up
Subtask 24-51-00-861-052-B ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 24-51-00-865-054-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUELEC/GALLEY/CNTOR7MCS28
122VUELEC/GALY & CAB/CTL1XAS26
123VUFWD GALLEY/FEEDER F16MCAC10
123VUAFT GALLEY/FEEDER E14MCAF09
** ON A/C NOT FOR ALL
123VUAFT GALLEY/FEEDER A3MCAF04
** ON A/C NOT FOR ALL
123VUAFT GALLEY/FEEDER B12MCAD09
123VUFWD GALLEY/FEEDER D2MCAD04
123VUFWD GALLEY/FEEDER C1MCAE10
** ON A/C NOT FOR ALL
123VUFWD GALLEY/FEEDER D2MCAE02
4. Procedure
Subtask 24-51-00-440-050-B ** ON A/C NOT FOR ALL
A. Do the trouble shooting of the galley supply system TSM 24-56-00-810-801.
5. Close-up
Subtask 24-51-00-862-051-B ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).