Visual Inspection of the External Power Receptacle
TASK 24-41-00-040-001-A
Visual Inspection of the External Power Receptacle
MMEL 24-41-02A
EXTERNAL POWER RECEPTACLE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 24-41-00-860-062-A
Subtask 24-41-00-210-051-A
Subtask 24-41-00-410-053-A
[Rev.10 from 2021]
2026.03.31 23:24:12 UTC
Visual Inspection of the External Power Receptacle
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobMMEL 24-41-02A
EXTERNAL POWER RECEPTACLE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | GUN - HOT AIR |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBB1) | Non Aqueous Cleaner-- Petroleum Based - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-42-12-000-001-A | Removal of the External-Power Receptacle Door (121AL) |
| TASK 52-42-12-400-001-A | Installation of the External-Power Receptacle Door (121AL) |
| SRM 512800 | |
| SRM 531113 | |
Subtask 24-41-00-860-062-A
A. Safety Precautions
(1) Make sure that the ground power source is not connected to the aircraft external-power receptacle.
Subtask 24-41-00-010-053-A (1) Make sure that the ground power source is not connected to the aircraft external-power receptacle.
B. Get Access
(1) Put an access platform in position at the external-power receptacle door (121AL).
(2) Open the external-power receptacle door (121AL).
4. Procedure(1) Put an access platform in position at the external-power receptacle door (121AL).
(2) Open the external-power receptacle door (121AL).
Subtask 24-41-00-210-051-A
A. Visual Inspection of the Electrical-Power Receptacle Assembly and the External-Power Receptacle Door
(1) Examine the electrical-power receptacle assembly.
(a) Examine the electrical-power receptacle assembly for overheat damage SRM 512800.
1 If there is overheat damage:
1 Make sure that there are no cracks on the external power receptacle and on the adjacent structure.
(c) Examine the aircraft structure around the electrical power receptacle.
1 If the aircraft structure is damaged:
(a) Open and close the external-power receptacle door (121AL).
(b) Make sure that the external-power receptacle door (121AL) operates correctly.
1 If the external-power receptacle door (121AL) does not operate correctly:
5. Close-up(1) Examine the electrical-power receptacle assembly.
(a) Examine the electrical-power receptacle assembly for overheat damage SRM 512800.
1 If there is overheat damage:
- Clean the electrical-power receptacle assembly with a Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) .
- Make sure that there are no holes on the receptacle and the adjacent structure.
1 Make sure that there are no cracks on the external power receptacle and on the adjacent structure.
(c) Examine the aircraft structure around the electrical power receptacle.
1 If the aircraft structure is damaged:
- Repair it SRM 531113.
(a) Open and close the external-power receptacle door (121AL).
(b) Make sure that the external-power receptacle door (121AL) operates correctly.
1 If the external-power receptacle door (121AL) does not operate correctly:
- Replace the external-power receptacle door (121AL) (Ref. AMM TASK 52-42-12-000-001) and (Ref. AMM TASK 52-42-12-400-001).
- Put a WARNING NOTICE(S) in position to tell persons not to connect power connector to the electrical power receptacle.
- Put a shrink sleeve ABS0916B07 in position below the pins A and B of the electrical power receptacle.
Shrink it with a GUN - HOT AIR.
Subtask 24-41-00-410-053-A
A. Close Access
(1) Close the external-power receptacle door (121AL).
Subtask 24-41-00-942-051-A (1) Close the external-power receptacle door (121AL).
B. Put the aircraft back to its initial configuration.
(1) Remove the access platform(s).
(2) Make an entry in the logbook.
(1) Remove the access platform(s).
(2) Make an entry in the logbook.