W DOC AIRBUS | AMM A320F

Installation of the Battery Shunt


TASK 24-38-54-400-001-A
Installation of the Battery Shunt


ZONE: 126
FIN: 3PB1
FIN: 3PB2
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 17.70 and 13.28 lbf.in (0.20 and 0.15 m.daN ) T
No specific
Torque wrench: range to between 79.62 and 53.10 lbf.in (0.90 and 0.60 m.daN ) T
No specific
Torque wrench: range to between 4.8 and 3.7 m.N (42.5 and 32.7 lbf.in ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
126
LATERAL AVIONIC COMPARTMENT
812, 822
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
6
LOCKWASHER
AIPC 24-38-01-02-042
3
LOCKWASHER
AIPC 24-38-01-02-047
6
LOCKWASHER
AIPC 24-38-81-02-042
3
LOCKWASHER
AIPC 24-38-81-02-047
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 24-38-54-860-050-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
   (2) In the cockpit, on the ELEC panel 35VU, make sure that these pushbutton switches are released:
  • BAT 1,
  • BAT 2.
   (3) In the cockpit, on the ELEC panel 35VU, make sure that the WARNING NOTICE(S) to tell persons not to operate the batteries, is in position.
   (4) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the avionics compartment doors 812 and 822.
   (5) Make sure that the access doors 812 and 822 are open.
   (6) Make sure that the access panels of the AC/DC emergency power center 106VU and the battery power center 105VU are open.
Subtask 24-38-54-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 2PB1 (BAT1)
105VUELEC/HOT BUS/701PP SPLY5PB1D01
105VUELEC/HOT BUS/701PP SPLY12PB1E01
106VUCSM/G /EV/MAN/SPLY6XEB04
122VUELEC/REFLNG/ON/BAT1PRU28
FOR FIN: 2PB2 (BAT2)
105VUELEC/HOT BUS/702PP SPLY5PB2D02
105VUELEC/HOT BUS/702PP SPLY12PB2E02
106VUCSM/G /EV/MAN/SPLY6XEB04
122VUELEC/REFLNG/ON/BAT1PRU28
4. Procedure
Subtask 24-38-54-420-050-A 5. Close-up
Subtask 24-38-54-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 2PB1 (BAT1)
105VUELEC/HOT BUS/701PP SPLY5PB1D01
105VUELEC/HOT BUS/701PP SPLY12PB1E01
106VUCSM/G /EV/MAN/SPLY6XEB04
122VUELEC/REFLNG/ON/BAT1PRU28
FOR FIN: 2PB2 (BAT2)
105VUELEC/HOT BUS/702PP SPLY5PB2D02
105VUELEC/HOT BUS/702PP SPLY12PB2E02
106VUCSM/G /EV/MAN/SPLY6XEB04
122VUELEC/REFLNG/ON/BAT1PRU28
Subtask 24-38-54-410-050-A
Subtask 24-38-54-862-050-A
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.03.31 23:23:59 UTC