Visual Inspection of the Batteries


TASK 24-38-00-210-001-A
Visual Inspection of the Batteries


1. Reason for the Job
Examination of the batteries.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
SPONGE
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
(Material No.14SBA1)
Textile-Lint free Cotton -
No specific
acetic acid
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
822
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 24-38-00-861-054-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 24-38-00-941-051-A
B. Safety Precautions
   (1) In the cockpit, on the overhead panel 35VU, make sure that the BAT 1 and 2 pushbutton switches are released (out).
   (2) In the cockpit, on the overhead panel 35VU, put a WARNING NOTICE(S) in position to tell the persons not to use the batteries.
Subtask 24-38-00-010-050-A
C. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 822.
   (2) Open the access door 822.
   (3) Open the access panel of the BATTERY power center 105VU.
Subtask 24-38-00-865-051-A
D. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/HOT BUS/702PP SPLY5PB2D02
105VUELEC/HOT BUS/701PP SPLY5PB1D01
4. Procedure
Subtask 24-38-00-210-050-A
A. Inspect the Batteries
   (1) To do this:
WARNING: DO NOT GET ELECTROLYTE ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
  • FLUSH IT AWAY IMMEDIATELY WITH CLEAN COLD WATER.
  • GET MEDICAL AID.
     (a) Disconnect the battery connector and put a CAP - BLANKING on the connector.
     (b) Examine the battery externally and make sure that these are in good condition:
  • case and lid,
  • latches,
  • pins of the electrical connector.
     (c) Examine the battery internally; to do this:
       1 Cut and remove the lockwire from the lid.
       2 Remove the lid and do a check of the condition of:
  • cells (electrolytic spillage, overheating, deformation),
  • connections between cells (oxidation),
  • safety valves.
If you find spilled electrolyte, overheat marks or deformation (such as a cell with a swollen case, damaged cell strap), replace the battery.
     (d) Install the lid and safety it with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
Subtask 24-38-00-210-051-A
B. Examine the Ventilation Ducts
   (1) To do this:
     (a) Do a check of the condition of the ventilation ducts (traces of electrolyte).
     (b) Remove the ducts to clean and wash them with water and, if necessary, remove the electrolyte.
     (c) Install the ducts.
Subtask 24-38-00-160-050-A
C. Clean of the Batteries Area
   (1) In areas which you can get access to easily:
Use a clean wet cloth to remove any trace of electrolyte. Be careful not to apply electrolyte all around with the cloth.
You must of ten clean the cloth not to have a larger area with contamination.
   (2) In areas which you cannot get access to easily (complex structure):
     (a) First clean the area with a 5 percent acetic acid solution.
NOTE: If acetic acid is not available, you can use pure household spirit vinegar as an alternative.
     (b) Then wipe and dry the area as well as possible with a clean cloth.
   (3) Electrical cables on which there is electrolyte contamination:
     (a) Clean the cables with a clean SPONGE or Textile-Lint free Cotton - (Material No.14SBA1) ; if the cable insulation is damaged, replace the cable.
   (4) If some electrolyte comes out of the battery, you must write a report to give details on:
  • the area where it occurred
  • the cleaning procedure used and
  • the cable repair you did.
This is necessary to do another check after 2 weeks.
5. Close-up
Subtask 24-38-00-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/HOT BUS/702PP SPLY5PB2D02
105VUELEC/HOT BUS/701PP SPLY5PB1D01
Subtask 24-38-00-410-050-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access panel of the BATTERY power center 105VU.
   (3) Close the access door 822.
   (4) Remove the access platform(s).
   (5) Remove the WARNING NOTICE(S).
Subtask 24-38-00-862-051-A
C. De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001).