Installation of the Voltmeters
TASK 24-37-21-400-001-A
Installation of the Voltmeters
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-37-21-860-050-A
Subtask 24-37-21-420-050-A
Subtask 24-37-21-862-050-A Subtask 24-37-21-410-050-A
[Rev.10 from 2021]
2026.03.31 23:23:44 UTC
Installation of the Voltmeters
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | ELECTRICAL CONTACTS INSERTION TOOL |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 24-37-21-860-050-A
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the avionics compartment door 822.
(3) Make sure that the access door 822 is open.
(4) Make sure that the access panel of the BATTERY power center 105VU is opened.
Subtask 24-37-21-865-051-A (1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the avionics compartment door 822.
(3) Make sure that the access door 822 is open.
(4) Make sure that the access panel of the BATTERY power center 105VU is opened.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 3PV1 (VOLTMETERBAT 1) | |||
| 105VU | ELEC/BAT REF/BCL1 | 9PB1 | F01 |
| FOR FIN: 3PV2 (VOLTMETERBAT 2) | |||
| 105VU | ELEC/BAT REF/BCL2 | 9PB2 | F02 |
Subtask 24-37-21-420-050-A
A. Installation of the Voltmeter
(2) Install the two screws (4) and tighten them.
(3) Connect the electrical wires (5) to the voltmeter (1) with the ELECTRICAL CONTACTS INSERTION TOOL.
(4) Install the panel 35VU (2) in its housing.
(5) Turn the four quick-release fasteners (3) by a quarter turn.
(6) Install the plate 13LF (6) on the panel 35VU.
(7) Install the 5 screws (7) and tighten them.
Subtask 24-37-21-865-052-A CAUTION:
REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES.
INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
(1) Put the voltmeter (1) in position. (2) Install the two screws (4) and tighten them.
(3) Connect the electrical wires (5) to the voltmeter (1) with the ELECTRICAL CONTACTS INSERTION TOOL.
(4) Install the panel 35VU (2) in its housing.
(5) Turn the four quick-release fasteners (3) by a quarter turn.
(6) Install the plate 13LF (6) on the panel 35VU.
(7) Install the 5 screws (7) and tighten them.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 24-37-21-710-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 3PV1 (VOLTMETERBAT 1) | |||
| 105VU | ELEC/BAT REF/BCL1 | 9PB1 | F01 |
| FOR FIN: 3PV2 (VOLTMETERBAT 2) | |||
| 105VU | ELEC/BAT REF/BCL2 | 9PB2 | F02 |
C. Check of the Battery Voltage
(1) Make sure that the battery voltage comes into view.
5. Close-up(1) Make sure that the battery voltage comes into view.
Subtask 24-37-21-862-050-A Subtask 24-37-21-410-050-A
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access panel of the BATTERY power center 105VU.
(3) Close the access door 822.
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access panel of the BATTERY power center 105VU.
(3) Close the access door 822.
(4) Remove the access platform(s).
Voltmeters of Batteries