W DOC AIRBUS | AMM A320F

Removal of the Voltmeters


TASK 24-37-21-000-001-A
Removal of the Voltmeters


ZONE: 210
FIN: 3PV1
FIN: 3PV2
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
ELECTRICAL CONTACTS EXTRACTION TOOL
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
822
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
3. Job Set-up
Subtask 24-37-21-861-051-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001)
Subtask 24-37-21-010-050-A
B. Get access to the avionics compartment.
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the avionics compartment door 822.
   (2) Open the access door 822.
   (3) Open the access panel of the BATTERY power center 105VU.
Subtask 24-37-21-865-050-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 3PV1 (VOLTMETERBAT 1)
105VUELEC/BAT REF/BCL19PB1F01
FOR FIN: 3PV2 (VOLTMETERBAT 2)
105VUELEC/BAT REF/BCL29PB2F02
4. Procedure
Subtask 24-37-21-020-050-A
A. Removal of the Voltmeter
CAUTION: MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
   (1) Remove the 5 screws (7).
   (2) Remove the integrally lighted identification plate 13LF (6).
   (3) Turn the four quick-release fasteners (3) by a quarter turn.
   (4) Remove the panel 35VU (2) from its housing; do not disconnect the electrical connectors from the rear plate.
   (5) Disconnect the electrical wires (5) from the voltmeter (1) with the ELECTRICAL CONTACTS EXTRACTION TOOL.
   (6) Loosen the two screws (4) and remove them.
   (7) Remove the voltmeter (1).
[Rev.10 from 2021] 2026.03.31 23:23:43 UTC