Removal of the Voltmeters
TASK 24-37-21-000-001-A
Removal of the Voltmeters
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-37-21-861-051-A Subtask 24-37-21-010-050-A
Subtask 24-37-21-020-050-A
[Rev.10 from 2021]
2026.03.31 23:23:43 UTC
Removal of the Voltmeters
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | ELECTRICAL CONTACTS EXTRACTION TOOL |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 24-37-21-861-051-A Subtask 24-37-21-010-050-A
B. Get access to the avionics compartment.
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the avionics compartment door 822.
(2) Open the access door 822.
(3) Open the access panel of the BATTERY power center 105VU.
Subtask 24-37-21-865-050-A (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the avionics compartment door 822.
(2) Open the access door 822.
(3) Open the access panel of the BATTERY power center 105VU.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 3PV1 (VOLTMETERBAT 1) | |||
| 105VU | ELEC/BAT REF/BCL1 | 9PB1 | F01 |
| FOR FIN: 3PV2 (VOLTMETERBAT 2) | |||
| 105VU | ELEC/BAT REF/BCL2 | 9PB2 | F02 |
Subtask 24-37-21-020-050-A
A. Removal of the Voltmeter
(2) Remove the integrally lighted identification plate 13LF (6).
(3) Turn the four quick-release fasteners (3) by a quarter turn.
(4) Remove the panel 35VU (2) from its housing; do not disconnect the electrical connectors from the rear plate.
(5) Disconnect the electrical wires (5) from the voltmeter (1) with the ELECTRICAL CONTACTS EXTRACTION TOOL.
(6) Loosen the two screws (4) and remove them.
(7) Remove the voltmeter (1).
CAUTION:
MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
(1) Remove the 5 screws (7). (2) Remove the integrally lighted identification plate 13LF (6).
(3) Turn the four quick-release fasteners (3) by a quarter turn.
(4) Remove the panel 35VU (2) from its housing; do not disconnect the electrical connectors from the rear plate.
(5) Disconnect the electrical wires (5) from the voltmeter (1) with the ELECTRICAL CONTACTS EXTRACTION TOOL.
(6) Loosen the two screws (4) and remove them.
(7) Remove the voltmeter (1).
Voltmeters of Batteries