Removal of the Contactor
TASK 24-35-55-000-001-A
Removal of the Contactor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-35-55-010-051-A
Subtask 24-35-55-020-050-A
[Rev.10 from 2021]
2026.03.31 23:23:38 UTC
Removal of the Contactor
WARNING:
MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT ELECTRICAL CIRCUITS.
THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 212 | COCKPIT |
| 121AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-11-41-000-001-A | Removal of the Third Occupant Seat |
Subtask 24-35-55-010-051-A
A. Get Access
(1) Remove the Third Occupant seat (Ref. AMM TASK 25-11-41-000-001).
(2) Remove the front panel on the bottom right side of the panel 120VU.
(3) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position at the access door 121AL.
(4) Open the access door 121AL.
Subtask 24-35-55-860-050-A (1) Remove the Third Occupant seat (Ref. AMM TASK 25-11-41-000-001).
(2) Remove the front panel on the bottom right side of the panel 120VU.
(3) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position at the access door 121AL.
(4) Open the access door 121AL.
B. Safety Precautions
(1) Make sure that the external power connector is not connected to the aircraft EXT PWR receptacle.
(2) Put WARNING NOTICE(S) in position on the access door 121AL to tell persons not to connect the external power connector to the aircraft EXT PWR receptacle.
(3) In the cockpit, on the ELEC panel 35VU, make sure that these pushbutton switches are released:
4. Procedure(1) Make sure that the external power connector is not connected to the aircraft EXT PWR receptacle.
(2) Put WARNING NOTICE(S) in position on the access door 121AL to tell persons not to connect the external power connector to the aircraft EXT PWR receptacle.
(3) In the cockpit, on the ELEC panel 35VU, make sure that these pushbutton switches are released:
- BAT 1, BAT 2,
- APU GEN,
- GEN 1, GEN 2,
- EXT PWR.
- 21VU (EMER ELEC PWR section),
- 25VU (APU section)
- 35VU (ELEC).
Subtask 24-35-55-020-050-A
A. Removal of the Contactor
(2) Put a blanking caps on the disconnect electrical connector (4) and the electrical receptacle.
(3) Loosen the captive screws (3).
CAUTION:
REMOVE THE CONTACTOR ONLY AND NOT THE BASE OR THE MODULE WHERE THE WIRES ARE CONNECTED.
(1) Disconnect the electrical connector (4). (2) Put a blanking caps on the disconnect electrical connector (4) and the electrical receptacle.
(3) Loosen the captive screws (3).
NOTE: Do not remove the captive screws (3) and the spring washers from the contactor (5).
(4) Remove the contactor (5).
Contactors