W DOC AIRBUS | AMM A320F

Replacement of the Fuse 20PC1


TASK 24-35-00-960-801-A
Replacement of the Fuse 20PC1


ZONE: 211
ZONE: 212
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
212
COCKPIT
121AL
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
2
FUSE
AIPC 24-35-08-01-150
2
FUSE
AIPC 24-35-88-01-120
2
FUSE
AIPC 24-38-08-01-120
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-38-51-000-001-A
Removal of the Battery
TASK 24-38-51-400-001-A
Installation of the Battery
TASK 25-11-41-000-001-A
Removal of the Third Occupant Seat
TASK 25-11-41-400-001-A
Installation of the Third Occupant Seat
ESPM 2046200
F Fuse 20PC1 ** ON A/C NOT FOR ALL
F Fuse 20PC1 ** ON A/C NOT FOR ALL
FOR [2PB1] (BAT-1)
TASK 31-21-00-750-002-A
Procedure to Set the Clock
3. Job Set-up
Subtask 24-35-00-010-050-A
A. Get Access
   (1) Remove the Third Occupant seat (Ref. AMM TASK 25-11-41-000-001).
   (2) On the bottom right side of rear panel 120VU, remove the access door (1).
   (3) Put an ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position at access door 121AL.
   (4) Open access door 121AL.
Subtask 24-35-00-860-050-A
B. Aircraft Maintenance Configuration
   (1) Make sure that the external power connector is not connected to the aircraft EXT PWR receptacle.
   (2) Make sure that the WARNING NOTICE(S) are in position on access door 121AL to tell persons not to connect the external power connector to the aircraft EXT PWR receptacle.
   (3) In the cockpit, on the ELEC control panel 35VU, make sure that these pushbutton switches are released:
  • BAT 1, BAT 2
  • APU GEN
  • GEN 1, GEN 2
  • EXT PWR.
   (4) In the cockpit, make sure that the WARNING NOTICE(S) are in position to tell persons not to operate the pushbutton switches on these overhead panels:
  • 21VU (EMER ELEC PWR section)
  • 25VU (APU section)
  • 35VU (ELEC).
Subtask 24-35-00-020-050-A
C. Disconnection of the Two Batteries
   (1) Disconnect the connectors from the batteries, refer to (Ref. AMM TASK 24-38-51-000-001).
4. Procedure
Subtask 24-35-00-960-050-A ** ON A/C NOT FOR ALL
A. Replacement of the Fuse
F Fuse 20PC1 ** ON A/C NOT FOR ALL
   (1) Loosen the nut (3).
   (2) Remove and discard the fuse (2).
   (3) Install the new AIPC 24-38-08-01-120 FUSE (2) on the terminals of the mount (4) as shown on the View B and C.
   (4) Tighten the nut (3)
ESPM 2046200.
Subtask 24-35-00-960-050-B ** ON A/C NOT FOR ALL Subtask 24-35-00-420-050-A Subtask 24-35-00-750-050-B
C. Adjustment of the Clock
   (1) FOR [2PB1] (BAT-1)
Adjust the clock (Ref. AMM TASK 31-21-00-750-002).
5. Close-up
Subtask 24-35-00-410-050-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) On the bottom right side of rear panel 120VU, install the access door (1).
   (3) Install the Third Occupant seat (Ref. AMM TASK 25-11-41-400-001).
   (4) Remove the WARNING NOTICE(S).
   (5) Close access door 121AL.
   (6) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 23:23:36 UTC