Removal of the Essential TR Contactor
TASK 24-34-55-000-001-A
Removal of the Essential TR Contactor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-34-55-010-050-A
Subtask 24-34-55-020-050-A
[Rev.10 from 2021]
2026.03.31 23:23:32 UTC
Removal of the Essential TR Contactor
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 125 | LATERAL AVIONIC COMPARTMENT |
| 812, 822 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 24-34-55-010-050-A
A. Get access to the avionics compartment.
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the avionics compartment doors 812 and 822.
(2) Open the access doors 812 and 822.
(3) Open the access panels of the AC/DC emergency power center 106VU and the access panels of the BATTERY power center 105VU.
Subtask 24-34-55-865-050-A (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the avionics compartment doors 812 and 822.
(2) Open the access doors 812 and 822.
(3) Open the access panels of the AC/DC emergency power center 106VU and the access panels of the BATTERY power center 105VU.
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 105VU | ELEC/CSM/G /EV AUTO/SPLY | 7XE | C01 |
| 106VU | CSM/G /EV/MAN/SPLY | 6XE | B04 |
| 106VU | ESS TR/SPLY | 4PE | C01 |
| 122VU | ELEC/CNTOR/ESS/DC BUS/TIE | 3PC | W26 |
| 123VU | AC ESS/BUS ON/BUS 1 | 1XC | AC12 |
| 123VU | AC ESS/BUS ON/BUS 2 | 2XC | AC01 |
Subtask 24-34-55-020-050-A
A. Removal of the Contactor
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Loosen the captive screws (3).
CAUTION:
REMOVE THE CONTACTOR ONLY AND NOT THE BASE OR THE MODULE WHERE THE WIRES ARE CONNECTED.
(1) Disconnect the connector (4). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Loosen the captive screws (3).
NOTE: Do not remove the captive screws (3) and the spring washers from contactor(5).
(4) Disengage the contactor (5) from the base (1) and remove the contactor.
Essential TR Contactor