Installation of the Static Inverter Contactor


TASK 24-28-55-400-001-A
Installation of the Static Inverter Contactor


CAUTION: MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT ELECTRICAL CIRCUITS. THERE IS A RISK OF DAMAGE TO EQUIPMENT DURING ITS REMOVAL/ INSTALLATION IF THE AC OR DC POWER STAYS CONNECTED.
ZONE: 126
FIN: 2XB
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 15.5808 and 13.0128 lbf.in (0.18 and 0.15 m.daN ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
126
LATERAL AVIONIC COMPARTMENT
822
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-28-00-710-001-A
Operational Test of the Static Inverter when the Aircraft Electrical Circuits are Energized from the External Power
TASK 24-28-00-710-001-A-01
Operational Test of the Static Inverter when the Aircraft Electrical Circuits are Energized from the APU
3. Job Set-up
Subtask 24-28-55-860-050-B
A. Aircraft Maintenance Configuration
   (1) In the cockpit, on the overhead panel 35VU, make sure these pushbutton switches are released:
  • BAT 1, BAT 2,
  • GEN 1, GEN 2,
  • EXT A.
   (2) In the cockpit, make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the pushbutton switches on these overhead panels:
  • 35VU (ELEC),
  • 21VU (EMER ELEC PWR).
   (3) Make sure that the external power connector is not connected to the aircraft receptable EXT PWR A.
   (4) On the access door 121AL, make sure that the WARNING NOTICE(S) is in position to tell persons not to connect the external power connector.
   (5) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 822.
   (6) Make sure that access door 822 is open.
   (7) In the avionics compartment, make sure that the access door from the panel 105VU is open.
   (8) Make sure that the batteries are disconnected.
Subtask 24-28-55-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/HOT BUS/702PP SPLY5PB2D02
105VUELEC/HOT BUS/701PP SPLY5PB1D01
105VUELEC/STAT INV/CNTOR/CTL14XBG02
106VUCSM/G /EV/MAN/SPLY6XEB04
122VUELEC/REFLNG/ON/BAT1PRU28
4. Procedure
Subtask 24-28-55-420-050-B Subtask 24-28-55-865-052-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/HOT BUS/702PP SPLY5PB2D02
105VUELEC/HOT BUS/701PP SPLY5PB1D01
105VUELEC/STAT INV/CNTOR/CTL14XBG02
106VUCSM/G /EV/MAN/SPLY6XEB04
122VUELEC/REFLNG/ON/BAT1PRU28
Subtask 24-28-55-710-050-A
5. Close-up
Subtask 24-28-55-410-050-B
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door of panel 105VU.
   (3) Close the access door 822.
   (4) Remove the access platform(s).
   (5) Remove the WARNING NOTICE(S).