Operational Test of the Static Inverter when the Aircraft Electrical Circuits are Energized from the APU
TASK 24-28-00-710-001-A-01
Operational Test of the Static Inverter when the Aircraft Electrical Circuits are Energized from the APU
Refer to the MPD TASK: 242800-01
OPERATIONAL CHECK OF STATIC INVERTER
Test of the correct power supply of the DC ESS BUS, AC ESS BUS and AC STAT INV BUS in emergency configuration when the batteries are the only power supply source.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-28-00-860-052-A
Subtask 24-28-00-860-053-A
[Rev.10 from 2021]
2026.03.31 23:23:01 UTC
Operational Test of the Static Inverter when the Aircraft Electrical Circuits are Energized from the APU
ZONE: 210
1. Reason for the JobRefer to the MPD TASK: 242800-01
OPERATIONAL CHECK OF STATIC INVERTER
Test of the correct power supply of the DC ESS BUS, AC ESS BUS and AC STAT INV BUS in emergency configuration when the batteries are the only power supply source.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 812, 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 24-28-00-860-052-A
A. Safety Precautions
(1) Do not energize the aircraft electrical circuits.
(2) On the panel 35VU, make sure that:
Subtask 24-28-00-010-051-A (1) Do not energize the aircraft electrical circuits.
(2) On the panel 35VU, make sure that:
- the BAT1 and BAT2 pushbutton switches are released,
- the BUS TIE and AC ESS FEED pushbutton switches are pushed.
NOTE: On the panel 2000VU, put the MAINT BUS switch (5XX) in the OFF position during the test.
B. Get access to the avionics compartment.
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE at the access doors 812 and 822 of the avionics compartment.
(2) Open the access doors 812 and 822.
Subtask 24-28-00-865-051-A (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE at the access doors 812 and 822 of the avionics compartment.
(2) Open the access doors 812 and 822.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 105VU | ELEC/HOT BUS/702PP SPLY | 5PB2 | D02 |
| 105VU | ELEC/HOT BUS/701PP SPLY | 5PB1 | D01 |
| 105VU | ELEC/BAT REF/BCL2 | 9PB2 | F02 |
| 105VU | ELEC/BAT REF/BCL1 | 9PB1 | F01 |
| 105VU | ELEC/STAT INV/CNTOR/CTL | 14XB | G02 |
| 105VU | ELEC/STAT INV/BUS 901XP/SPLY | 12XB | H02 |
| 106VU | AC ESS BUS/EMER/STBY/CNTOR/SPLY | 10XE | C06 |
WARNING:
TELL ALL THE PERSONS ON THE AIRCRAFT THAT:
Subtask 24-28-00-710-051-B - THE LIGHTS WILL GO OFF DURING THIS TEST
- THEY MUST NOT MOVE ON THE AIRCRAFT UNTIL THIS TEST IS COMPLETED.
A. Operational Test of the Static Inverter
5. Close-up| ACTION | RESULT |
|---|---|
1.On the ELEC panel 35VU:
| |
2.Power supply the aircraft electrical circuits:
| |
| 3.Do the EIS start procedure (upper ECAM DU and lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001). | |
4.On the ECAM control panel:
| On the lower ECAM display unit:
|
5.On the ELEC panel 35VU:
| On the ELEC panel 35VU:
|
|
|
|
|
|
|
| | On the lower ECAM display unit:
NOTE: If the current does not decrease after 10 seconds, it is necessary to do a charging cycle of the batteries. When the charging cycle is completed (batteries no longer connected to the DC BAT BUS), do the check again. |
6.On the ELEC panel 35VU:
| On the ELEC panel 35VU:
|
7.On the panel 21VU, in the section EMER ELEC PWR:
| |
On the ELEC panel 35VU:
| On the ELEC panel 35VU:
|
8.On the ECAM control panel:
| On the upper ECAM display unit:
NOTE: There is no green line between the STAT INV box and the AC ESS and DC ESS indications. |
| | On the ELEC panel 35VU:
|
9.On the ELEC panel 35VU:
| On the ELEC panel 35VU:
|
10.On the panel 21VU:
| |
11.On the ECAM control panel:
| On the lower ECAM display unit:
|
Subtask 24-28-00-860-053-A
A. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits from the APU (Ref. AMM TASK 24-41-00-862-002).
Subtask 24-28-00-410-051-A (1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits from the APU (Ref. AMM TASK 24-41-00-862-002).