W DOC AIRBUS | AMM A320F

Installation of the AC Essential Bus Switching Contactor


TASK 24-25-55-400-001-A
Installation of the AC Essential Bus Switching Contactor


WARNING: MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT ELECTRICAL CIRCUITS. THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.
ZONE: 125
FIN: 3XC
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 0.176 and 0.147 m.daN (15.58 and 13.01 lbf.in ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
125
LATERAL AVIONIC COMPARTMENT
812
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-25-00-710-001-A
Operational Check of AC ESS Generation Switching
3. Job Set-up
Subtask 24-25-55-860-050-A
A. Aircraft Maintenance Configuration
   (1) In the cockpit, on the overhead panel 35VU, make sure that these puhbutton switches are released:
  • BAT 1, BAT 2,
  • GEN 1, GEN 2,
  • EXT A.
   (2) In the cockpit, make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the pushbutton switches on these panels of the overhead panels:
  • 35VU (ELEC),
  • 21VU (EMER ELEC PWR).
   (3) Make sure that the external power connector is not connected to the aircraft receptable EXT PWR A.
   (4) On the access door 121AL, make sure that the WARNING NOTICE(S) is in position to tell persons not to connect the external power connector.
   (5) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 812.
   (6) Make sure that the access door 812 is open.
   (7) In the avionics compartment, make sure that the access door (14) is removed from the panel 106VU.
Subtask 24-25-55-865-050-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/CSM/G /EV AUTO/SPLY7XEC01
106VUCSM/G /EV/MAN/SPLY6XEB04
106VUESS TR/SPLY4PEC01
122VUELEC/CNTOR/ESS/DC BUS/TIE3PCW26
123VUAC ESS/BUS ON/BUS 11XCAC12
123VUAC ESS/BUS ON/BUS 22XCAC01
4. Procedure
Subtask 24-25-55-420-050-A
A. Installation of the Contactor
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Put the contactor (8) in position on the studs (11).
   (4) Install the washers (9) and the nuts (7), then tighten the nuts.
   (5) Install the electrical wires:
CAUTION: REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
     (a) Install the electrical power-supply wires (6).
     (b) Install the plates (5) and (10), the spring washers (4) and the nuts (3),
     (c) TORQUE the nuts (3) to between 0.176 and 0.147 m.daN (15.58 and 13.01 lbf.in ) T.
   (6) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (7) Make sure that all the electrical connections are clean and in the correct condition.
   (8) Connect the 2 electrical connectors (1, 2).
Subtask 24-25-55-865-051-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/CSM/G /EV AUTO/SPLY7XEC01
106VUCSM/G /EV/MAN/SPLY6XEB04
106VUESS TR/SPLY4PEC01
122VUELEC/CNTOR/ESS/DC BUS/TIE3PCW26
123VUAC ESS/BUS ON/BUS 11XCAC12
123VUAC ESS/BUS ON/BUS 22XCAC01
Subtask 24-25-55-710-050-A
5. Close-up
Subtask 24-25-55-410-050-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access door (14) on the panel 106VU.
   (3) Remove the WARNING NOTICE(S).
   (4) Close the access door 812.
   (5) Remove the access platform(s).
[Rev.10 from 2021] 2026.03.31 23:22:51 UTC