Installation of the Emergency Generator Line Contactor (EMER GLC)


TASK 24-24-55-400-001-A
Installation of the Emergency Generator Line Contactor (EMER GLC)


WARNING: MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT ELECTRICAL CIRCUITS. THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.
ZONE: 125
FIN: 2XE
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
125
LATERAL AVIONIC COMPARTMENT
812, 822
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-24-00-710-001-A
Operational Check of Emergency Generating System
ESPM 204524
3. Job Set-up
Subtask 24-24-55-860-052-A
A. Aircraft Maintenance Configuration
   (1) In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are realeased:
  • BAT 1, BAT 2,
  • GEN 1(2), APU GEN,
  • EXT PWR.
   (2) Make sure that there is a WARNING NOTICE(S) in the cockpit to tell persons not to operate the pushbutton switches on the overhead panels:
  • 21VU (EMER ELEC PWR),
  • 35VU (ELEC).
   (3) Make sure that the external power connector is not connected to the aircraft receptable EXT PWR.
   (4) Make sure that there is a WARNING NOTICE(S) on the access door 121AL to tell persons not to connect the external power connector.
   (5) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE are in position at the access doors 812 and 822.
   (6) Make sure that the access doors 812 and 822 are open.
   (7) In the avionics compartment, make sure that the access panel (1) from the AC/DC emergency power center 106VU is open.
Subtask 24-24-55-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/CSM/G /EV AUTO/SPLY7XEC01
106VUESS TR/SPLY4PEC01
122VUELEC/CNTOR/ESS/DC BUS/TIE3PCW26
123VUAC ESS/BUS ON/BUS 11XCAC12
123VUAC ESS/BUS ON/BUS 22XCAC01
4. Procedure
Subtask 24-24-55-420-050-A
A. Installation of the Contactor
CAUTION: REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
   (1) Put the contactor (7) in position.
   (2) Install the nuts (2) and tighten them.
   (3) Install the power supply wires (3).
   (4) Install the 6 washers (4) and screws (5). Tighten the screws (5) ESPM 204524.
   (5) Connect the wires (6) to the contactor (7).
Subtask 24-24-55-865-052-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/CSM/G /EV AUTO/SPLY7XEC01
106VUESS TR/SPLY4PEC01
122VUELEC/CNTOR/ESS/DC BUS/TIE3PCW26
123VUAC ESS/BUS ON/BUS 11XCAC12
123VUAC ESS/BUS ON/BUS 22XCAC01
Subtask 24-24-55-710-050-A
C. Do an operational test of the emergency AC generation system (Ref. AMM TASK 24-24-00-710-001).
5. Close-up
Subtask 24-24-55-410-050-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panel (1) on the AC/DC emergency power center 106VU.
   (3) Close the access doors 812 and 822.
   (4) Remove the WARNING NOTICE(S).
   (5) Remove the access platform(s).