Removal of the EGIU-1(2)


TASK 24-22-33-000-001-A
Removal of the EGIU-1(2)


ZONE: 121
ZONE: 122
FIN: 22XU1 ** ON A/C NOT FOR ALL
FIN: 22XU2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
122
AVIONICS COMPARTMENT
811
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
3. Job Set-up
Subtask 24-22-33-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
   (2) On the center pedestal, on the ENG panel 115VU:
  • put a WARNING NOTICE(S) to tell persons not to start the engine.
Subtask 24-22-33-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 22XU1 (EGIU1)
122VUELEC/GCU/12XU1T26
122VUELEC/IDG1/DISC1XTT24
122VUELEC/EXT PWR/LT CLT/AVAIL4XGX31
122VUELEC/EXT PWR/CTL11XGX29
122VUELEC/EXT PWR/COCKPIT/AVAIL/LT12XGX28
122VUELEC/EXT PWR/EGIU1/28VDC26XU1Z31
122VUELEC/GEN1/EGIU1/28VDC24XU1Z30
123VUEXT PWR/EGIU1/115VAC23XGAA07
123VUGEN1/EGIU1/115VAC23XU1AF12
FOR FIN: 22XU2 (EGIU2)
122VUELEC/GEN1/OFF/BTC2 SPLY14XUT30
122VUELEC/GCU/22XU2T27
122VUELEC/IDG2/DISC2XTT25
122VUAPU GEN/EGIU2/28VDC26XU2Y31
122VUGEN2/EGIU2/28VDC24XU2Y30
123VUAPU GEN/EGIU2/115VAC23XSAA08
123VUGEN2/EGIU2/115VAC23XU2AF01
Subtask 24-22-33-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE at the access door 811 of the avionics compartment.
   (2) Open the access door 811.
4. Procedure
Subtask 24-22-33-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the EGIU
   (1) Loosen the knurled nut (1).
   (2) Lower the knurled nut (1) to disengage the stud (2).
   (3) Carefully pull the handle (3) until the EGIU (4) is disconnected from the rack receptacle (5).
   (4) Remove the EGIU from the rack (6).
   (5) Put CAP - BLANKING on the rack receptacle (5) and on the EGIU connector.