Removal of the EGIU-1(2)
TASK 24-22-33-000-001-A
Removal of the EGIU-1(2)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-22-33-860-052-A ** ON A/C NOT FOR ALL
Subtask 24-22-33-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:22:07 UTC
Removal of the EGIU-1(2)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| 122 | AVIONICS COMPARTMENT |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 24-22-33-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(2) On the center pedestal, on the ENG panel 115VU:
Subtask 24-22-33-865-050-A ** ON A/C NOT FOR ALL (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(2) On the center pedestal, on the ENG panel 115VU:
- put a WARNING NOTICE(S) to tell persons not to start the engine.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 24-22-33-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 22XU1 (EGIU1) | |||
| 122VU | ELEC/GCU/1 | 2XU1 | T26 |
| 122VU | ELEC/IDG1/DISC | 1XT | T24 |
| 122VU | ELEC/EXT PWR/LT CLT/AVAIL | 4XG | X31 |
| 122VU | ELEC/EXT PWR/CTL | 11XG | X29 |
| 122VU | ELEC/EXT PWR/COCKPIT/AVAIL/LT | 12XG | X28 |
| 122VU | ELEC/EXT PWR/EGIU1/28VDC | 26XU1 | Z31 |
| 122VU | ELEC/GEN1/EGIU1/28VDC | 24XU1 | Z30 |
| 123VU | EXT PWR/EGIU1/115VAC | 23XG | AA07 |
| 123VU | GEN1/EGIU1/115VAC | 23XU1 | AF12 |
| FOR FIN: 22XU2 (EGIU2) | |||
| 122VU | ELEC/GEN1/OFF/BTC2 SPLY | 14XU | T30 |
| 122VU | ELEC/GCU/2 | 2XU2 | T27 |
| 122VU | ELEC/IDG2/DISC | 2XT | T25 |
| 122VU | APU GEN/EGIU2/28VDC | 26XU2 | Y31 |
| 122VU | GEN2/EGIU2/28VDC | 24XU2 | Y30 |
| 123VU | APU GEN/EGIU2/115VAC | 23XS | AA08 |
| 123VU | GEN2/EGIU2/115VAC | 23XU2 | AF01 |
C. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE at the access door 811 of the avionics compartment.
(2) Open the access door 811.
4. Procedure(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE at the access door 811 of the avionics compartment.
(2) Open the access door 811.
Subtask 24-22-33-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the EGIU
(1) Loosen the knurled nut (1).
(2) Lower the knurled nut (1) to disengage the stud (2).
(3) Carefully pull the handle (3) until the EGIU (4) is disconnected from the rack receptacle (5).
(4) Remove the EGIU from the rack (6).
(5) Put CAP - BLANKING on the rack receptacle (5) and on the EGIU connector.
(1) Loosen the knurled nut (1).
(2) Lower the knurled nut (1) to disengage the stud (2).
(3) Carefully pull the handle (3) until the EGIU (4) is disconnected from the rack receptacle (5).
(4) Remove the EGIU from the rack (6).
(5) Put CAP - BLANKING on the rack receptacle (5) and on the EGIU connector.
Electrical Generation Interface Unit 1(2)