Installation of the TDC AC Sensor 1(2)
TASK 24-22-18-400-001-A
Installation of the TDC AC Sensor 1(2)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-22-18-860-050-A ** ON A/C NOT FOR ALL
Subtask 24-22-18-420-050-A ** ON A/C NOT FOR ALL
Subtask 24-22-18-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:22:06 UTC
Installation of the TDC AC Sensor 1(2)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 126 | LATERAL AVIONIC COMPARTMENT |
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-740-004-A | Operational Check of the GPCU via the CFDS |
Subtask 24-22-18-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 822 of the electronics compartment.
(2) Make sure that the access door 822 is open.
(3) Make sure that the access door 103VU (5) is open.
Subtask 24-22-18-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 822 of the electronics compartment.
(2) Make sure that the access door 822 is open.
(3) Make sure that the access door 103VU (5) is open.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 50XU1 (SENSORTDC AC, 1) | |||
| 122VU | ELEC/GCU/1 | 2XU1 | T26 |
| 122VU | ELEC/IDG1/DISC | 1XT | T24 |
| FOR FIN: 50XU2 (SENSORTDC AC, 2) | |||
| 122VU | ELEC/GCU/2 | 2XU2 | T27 |
| 122VU | ELEC/IDG2/DISC | 2XT | T25 |
Subtask 24-22-18-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the TDC AC Sensor
(1) Put the sensor (3) in position on the barrels (2) of the base (1).
(2) Tighten the screws (4).
Subtask 24-22-18-865-052-A ** ON A/C NOT FOR ALL (1) Put the sensor (3) in position on the barrels (2) of the base (1).
(2) Tighten the screws (4).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 24-22-18-710-050-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | ELEC/GCU/2 | 2XU2 | T27 |
| 122VU | ELEC/GCU/1 | 2XU1 | T26 |
| 122VU | ELEC/IDG2/DISC | 2XT | T25 |
| 122VU | ELEC/IDG1/DISC | 1XT | T24 |
Subtask 24-22-18-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 103VU (5).
(3) Close the access door 822.
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 103VU (5).
(3) Close the access door 822.
(4) Remove the access platform(s).
Time Delay Closing (TDC) AC Sensor