Removal of the IDG Oil Cooler for Cleaning in Workshop
TASK 24-21-42-100-804-A
Removal of the IDG Oil Cooler for Cleaning in Workshop
1. Reason for the Job
Refer to the MPD TASK: 242100-20
REMOVE IDG COOLER FOR IN-SHOP CLEANING
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 24-21-42-020-071-A 4. Procedure
Subtask 24-21-42-110-056-A
Subtask 24-21-42-420-079-A
[Rev.10 from 2021]
2026.03.31 23:21:01 UTC
Removal of the IDG Oil Cooler for Cleaning in Workshop
1. Reason for the Job
Refer to the MPD TASK: 242100-20
REMOVE IDG COOLER FOR IN-SHOP CLEANING
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 437 | FAN COWL |
| 447 | FAN COWL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 73-11-50-000-802-A | Removal of the Integrated Drive Generator (IDG) Oil Cooler |
| TASK 73-11-50-400-802-A | Installation of the Integrated Drive Generator (IDG) Oil Cooler |
Subtask 24-21-42-020-071-A 4. Procedure
Subtask 24-21-42-110-056-A
A. Cleaning of the IDG Oil Cooler
(1) Send the IDG oil cooler to the workshop.
(a) Clean the IDG oil cooler.
5. Close-up(1) Send the IDG oil cooler to the workshop.
(a) Clean the IDG oil cooler.
Subtask 24-21-42-420-079-A
A. Installation of the IDG Oil Cooler
(1) Install the IDG oil cooler (Ref. AMM TASK 73-11-50-400-802).