W DOC AIRBUS | AMM A320F

Removal of the AC Generator Fuel/Oil Differential Pressure-Sensor


TASK 24-21-42-000-804-A
Removal of the AC Generator Fuel/Oil Differential Pressure-Sensor


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 451
ZONE: 461
FIN: 9XT1 ** ON A/C NOT FOR ALL
FIN: 9XT2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
1
CONTAINER 20 L (5.3 USGAL) - OIL RESISTANT
No specific
AR
COVER - PROTECTION
No specific
1
PLIERS - JAWED, SOFT
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
451
THRUST REVERSER
461
THRUST REVERSER
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR, 451AL
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 461AL
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-832-A
Procedure to Prevent Engine Motoring and to Stop the Electrical Supply to the EEC
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 24-21-42-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring and to stop the electrical supply to the Electronic Engine Control (EEC)
(Ref. AMM TASK 71-00-00-860-832).
Subtask 24-21-42-010-054-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 24-21-42-040-050-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser System for Ground Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 24-21-42-010-056-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the left thrust reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
   (2) Put an ACCESS PLATFORM 1M(3 FT) in position.
   (3) Installation of the engine protection covers
CAUTION: INSTALL PROTECTION COVERS ON ALL THE OPENINGS IMMEDIATELY TO PREVENT DAMAGE TO THE ENGINE.
     (a) Install all the necessary COVER - PROTECTION to prevent damage to the engine.
4. Procedure
Subtask 24-21-42-020-066-A ** ON A/C NOT FOR ALL
A. Removal of the AC Generator Fuel/Oil Differential Pressure-Sensor
CAUTION: WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
   (1) Find the sensor (4) attached to the IDG fuel/heat exchanger at the 9 o'clock position.
   (2) Place a CONTAINER 20 L (5.3 USGAL) - OIL RESISTANT below the sensor (4) on the Thermal Management System (TMS) manifold.
   (3) Disconnect the wiring harness (WC11) connector (P37) from the sensor receptacle (J34) with the PLIERS - JAWED, SOFT.
   (4) Loosen the two bolts (1) on the TMS manifold.
   (5) Turn the sensor (4) to disengage it from the two bolts (1) on the TMS manifold.
   (6) Remove the sensor (4) from the TMS manifold.
   (7) Remove and discard the packings (2) and (3).
   (8) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) to remove oil leakage.
[Rev.10 from 2021] 2026.03.31 23:20:56 UTC