Visual Inspection of the IDG for Oil Leaks and Check of the Electrical Circuits
TASK 24-21-00-210-048-A
Visual Inspection of the IDG for Oil Leaks and Check of the Electrical Circuits
1. Reason for the Job
To make sure that the IDG oil system is serviceable and to do a check for leakage, staining or wetting.
To make sure that the wiring harnesses are in the correct condition.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-21-00-941-085-A ** ON A/C NOT FOR ALL
Subtask 24-21-00-210-087-A ** ON A/C NOT FOR ALL
Subtask 24-21-00-410-097-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:20:21 UTC
Visual Inspection of the IDG for Oil Leaks and Check of the Electrical Circuits
1. Reason for the Job
To make sure that the IDG oil system is serviceable and to do a check for leakage, staining or wetting.
To make sure that the wiring harnesses are in the correct condition.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-13-24-612-011-A | Integrated Drive Generator (IDG) Servicing - Filling of the IDG with Oil or Addition of Oil after a Level Check |
| TASK 24-21-42-000-010-B | Removal of the Fuel-Cooled IDG Oil-Cooler |
| TASK 24-21-42-400-010-B | Installation of the Fuel-Cooled IDG Oil-Cooler |
| TASK 24-21-49-200-010-A | General Check of the IDG Oil Cooling Tubes |
| TASK 24-21-51-000-010-A | Removal of the Integrated Drive Generator -IDG 1(2) |
| TASK 24-21-51-400-010-B | Installation of the Integrated Drive Generator - IDG 1(2), (New EPGS) |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
Subtask 24-21-00-941-085-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
Subtask 24-21-00-010-098-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the right fan-cowl door (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
438AR
(b) FOR [1000EM2] (ENGINE-2)
448AR
4. Procedure(1) Open the right fan-cowl door (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
438AR
(b) FOR [1000EM2] (ENGINE-2)
448AR
Subtask 24-21-00-210-087-A ** ON A/C NOT FOR ALL
A. Visual Inspection
(1) Do a visual inspection of these components:
(c) IDG oil cooler for leakage:
(2) If you find components wet with oil, make sure that you find and correct all the causes.
If necessary, fill the oil tank (Ref. AMM TASK 12-13-24-612-011).
Subtask 24-21-00-210-088-A ** ON A/C NOT FOR ALL (1) Do a visual inspection of these components:
NOTE: There can be different signs of possible leakage:
(a) IDG fittings for leakage: - Droplets of oil
- Wet areas around connections, oil stripes on tubes
- Stains or discoloration which can occur when oil or grease is in contact with very hot surfaces.
- Pressure fill port
- Overflow drain port
- Oil-in and oil-out ports (cooling circuit interface with the IDG)
- Case drain.
- The pressure fill port, replace the pressure fill half-coupling (Ref. AMM TASK 24-21-51-000-010) and (Ref. AMM TASK 24-21-51-400-010).
- The overflow drain port, replace the overflow drain half-coupling (Ref. AMM TASK 24-21-51-000-010) and (Ref. AMM TASK 24-21-51-400-010).
- The oil-in and oil-out ports (cooling circuit interface with IDG) or case drain, replace the related fitting.
(c) IDG oil cooler for leakage:
- Oil-in and oil-out ports (cooling circuit interface with the cooler)
- Drain plug
- Body of the cooler.
(2) If you find components wet with oil, make sure that you find and correct all the causes.
If necessary, fill the oil tank (Ref. AMM TASK 12-13-24-612-011).
B. Check of the Electrical Circuits
(1) Make sure that the wiring harnesses are in the correct condition.
(2) Make sure that the electrical connectors are correctly connected.
5. Close-up(1) Make sure that the wiring harnesses are in the correct condition.
(2) Make sure that the electrical connectors are correctly connected.
Subtask 24-21-00-410-097-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the right fancowl door (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
438AR
(b) FOR [1000EM2] (ENGINE-2)
448AR.
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the right fancowl door (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
438AR
(b) FOR [1000EM2] (ENGINE-2)
448AR.
(3) Remove the WARNING NOTICE(S).