Disconnection of the Defective IDG and Draining of the IDG Oil
TASK 24-20-00-040-803-A
Disconnection of the Defective IDG and Draining of the IDG Oil
MMEL 24-09-03D
ELEC IDG 1(2) OIL LO LVL ALERT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 24-20-00-941-051-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-160-051-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:19:29 UTC
Disconnection of the Defective IDG and Draining of the IDG Oil
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
WEAR GOGGLES, INSULATED GLOVES AND OTHER PROTECTIVE CLOTHES.
HOT OIL CAN BURN YOUR EYES AND SKIN.
IF OIL TOUCHES YOUR EYES OR SKIN, GET MEDICAL AID.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
DO NOT LET ENGINE OIL FALL ON THE ENGINE. UNWANTED OIL MUST BE REMOVED IMMEDIATELY. THE OIL CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
CAUTION:
DO NOT USE SOLVENTS THAT CONTAIN CHLORINE TO CLEAN THE EQUIPMENT (PUMP, HOSES, TANK AND FUNNEL) USED TO FILL THE IDG WITH OIL.
CHLORINE CONTAMINATION OF THE OIL CAN CAUSE FAST DETERIORATION OF THE OIL AND WILL DECREASE THE LIFE OF THE IDG.
CAUTION:
DO NOT OPERATE THE IDG:
1. Reason for the Job- IF IT CONTAINS TOO MUCH OIL
- IF IT DOES NOT CONTAIN ENOUGH OIL
MMEL 24-09-03D
ELEC IDG 1(2) OIL LO LVL ALERT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 2 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | AIR SOURCE FILTERED, DRY |
| No specific | AR | COVER - PROTECTION |
| No specific | AR | LIGHT SOURCE - INSPECTION |
| No specific | AR | MIRROR - INSPECTION |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBB1) | Non Aqueous Cleaner-- Petroleum Based - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 451AL | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 461AL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-13-24-680-802-A | Draining of the Oil from the Integrated Drive Generator (IDG) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 71-00-00-860-814-A | Shutdown of the Engine |
| TASK 71-00-00-860-823-A | Start the Engine (Normal Automatic Start) |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-36-00-010-802-A | Opening of the Thrust Reverser Cowl-Doors |
| TASK 78-36-00-410-802-A | Closing of the Thrust Reverser Cowl-Doors |
| TSM 24-21-00-810-815 | The Differential Pressure Indicator (DPI) of the IDG1 Oil Filter is Extended - Alternate Procedure |
| TSM 24-21-00-810-816 | The Differential Pressure Indicator (DPI) of the IDG2 Oil Filter is Extended - Alternate Procedure |
Subtask 24-20-00-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the ELEC key to get the ELEC page.
(4) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(5) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 24-20-00-010-051-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the ELEC key to get the ELEC page.
(4) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(5) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 24-20-00-040-052-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
C. Deactivation of the Thrust Reverser System for Ground Maintenance
Subtask 24-20-00-010-052-A ** ON A/C NOT FOR ALL WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805). D. Get Access
(1) Open the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
(2) Put an ACCESS PLATFORM 1M(3 FT) in position.
4. Procedure(1) Open the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
(2) Put an ACCESS PLATFORM 1M(3 FT) in position.
Subtask 24-20-00-160-051-A ** ON A/C NOT FOR ALL
A. Cleaning of the IDG Oil Sight-Glass for Correct Conditions
(a) If the IDG oil sight-glass is not clean:
Subtask 24-20-00-210-056-A ** ON A/C NOT FOR ALL WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
(1) Make sure that the IDG oil sight-glass is clean. - FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
(a) If the IDG oil sight-glass is not clean:
- Clean the sight glass with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) , and
- Remove the remaining solvent with a clean Textile-Lint free Cotton - (Material No.14SBA1) or blow air on the sight glass with a AIR SOURCE FILTERED, DRY to dry it.
B. Check of the IDG Maintenance Conditions
(1) Make sure that the red button of the DPI of the oil filter is not extended.
Use an LIGHT SOURCE - INSPECTION and an MIRROR - INSPECTION, if necessary.
(a) If the red button of the DPI of the oil filter is extended:
Subtask 24-20-00-210-057-A ** ON A/C NOT FOR ALL (1) Make sure that the red button of the DPI of the oil filter is not extended.
Use an LIGHT SOURCE - INSPECTION and an MIRROR - INSPECTION, if necessary.
(a) If the red button of the DPI of the oil filter is extended:
- Do the troubleshooting procedure for the DPI of the oil-filter that is extended TSM 24-21-00-810-815 or TSM 24-21-00-810-816.
- If the IDG oil level is lower red band, continue the maintenance procedure.
C. Visual Inspection of IDG for Oil Leaks
(a) Make an entry in the log book to record the position of the oil leaks.
(b) Continue the maintenance procedure.
Subtask 24-20-00-410-055-A ** ON A/C NOT FOR ALL NOTE: Do not a visual inspection for oil leaks at the drain mast.
(1) Do a visual inspection of these components: NOTE: There can be different signs of possible leaks:
- Droplets of oil
- Wet areas around connections, oil stripes on tubes
- Stains or discoloration which can occur when oil or grease goes on very hot surfaces.
- Pressure fill port
- Overflow drain port
- Oil-in and oil-out ports (cooling system interface with the IDG)
- Case drain.
- Tubing.
- Oil-in and oil-out fittings of the thermal management system module
- Body of the heat exchanger.
- Oil-in and oil-out fittings of the thermal management system module
- Body of the heat exchanger.
(a) Make an entry in the log book to record the position of the oil leaks.
(b) Continue the maintenance procedure.
D. Close Access
(1) Remove the ACCESS PLATFORM 1M(3 FT).
(2) Close the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
Subtask 24-20-00-440-055-A ** ON A/C NOT FOR ALL (1) Remove the ACCESS PLATFORM 1M(3 FT).
(2) Close the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
E. Reactivation of the Thrust Reverser System after Ground Maintenance
(1) Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 24-20-00-410-056-A ** ON A/C NOT FOR ALL (1) Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-805).
F. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
Subtask 24-20-00-860-059-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
G. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the ELEC key to get the ELEC page.
Subtask 24-20-00-865-054-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the ELEC key to get the ELEC page.
H. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 24-20-00-020-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 4000XU1 (IDGENG 1) | |||
| 122VU | ELEC/GCU/1 | 2XU1 | T26 |
| 122VU | ELEC/IDG1/DISC | 1XT | T24 |
| FOR FIN: 4000XU2 (IDGENG 2) | |||
| 122VU | ELEC/GCU/2 | 2XU2 | T27 |
| 122VU | ELEC/IDG2/DISC | 2XT | T25 |
I. Disconnection of the IDG
(1) Start the engine 1(2) (Ref. AMM TASK 71-00-00-860-823).
(2) Make sure that at least the IDG 1(2) and the external power or the APU generator energize the electrical circuits.
(3) Make an entry in the log book to tell persons that you disconnect the IDG(1)2.
(4) Stop the engine 1(2) (Ref. AMM TASK 71-00-00-860-814).
Subtask 24-20-00-941-053-A ** ON A/C NOT FOR ALL (1) Start the engine 1(2) (Ref. AMM TASK 71-00-00-860-823).
(2) Make sure that at least the IDG 1(2) and the external power or the APU generator energize the electrical circuits.
NOTE: This test is for the system 1. For the other system(s), use the indications between the parentheses.
| ACTION | RESULT |
|---|---|
1.With the engine 1(2) at idle speed, on ELEC control panel 35VU:
| On ELEC control panel 35VU:
|
| | On the lower ECAM DU, on the ELEC page:
|
2.On ELEC control panel 35VU:
| On ELEC control panel 35VU:
|
3.On ELEC control panel 35VU:
| |
(4) Stop the engine 1(2) (Ref. AMM TASK 71-00-00-860-814).
J. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
Subtask 24-20-00-010-055-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate:
- The ENG/MODE selector switch, and
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
K. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 24-20-00-040-054-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
L. Deactivation of the Thrust Reverser System for Ground Maintenance
Subtask 24-20-00-010-056-A ** ON A/C NOT FOR ALL WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805). M. Get Access
(1) Open the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
(2) Put an ACCESS PLATFORM 1M(3 FT) in position.
(3) Installation of the engine protection covers
Subtask 24-20-00-680-050-A ** ON A/C NOT FOR ALL (1) Open the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
(2) Put an ACCESS PLATFORM 1M(3 FT) in position.
(3) Installation of the engine protection covers
CAUTION:
INSTALL PROTECTION COVERS ON ALL THE OPENINGS IMMEDIATELY TO PREVENT DAMAGE TO THE ENGINE.
(a) Install all the necessary COVER - PROTECTION to prevent damage to the engine. N. Draining of the Oil from the IDG1(2)
(1) Drain the oil from the IDG (Ref. AMM TASK 12-13-24-680-802).
Subtask 24-20-00-710-057-A ** ON A/C NOT FOR ALL (1) Drain the oil from the IDG (Ref. AMM TASK 12-13-24-680-802).
O. CAUTION to Prevent Damage to IDG1(2)
5. Close-upSubtask 24-20-00-410-051-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
Subtask 24-20-00-440-053-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
B. Reactivation of the Thrust Reverser System after Ground Maintenance
(1) Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 24-20-00-410-052-A ** ON A/C NOT FOR ALL (1) Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-805).
C. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
Subtask 24-20-00-862-059-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
D. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
IDG Oil Level Sight Glass and DPI