Check of the AC Main Generation Maintenance Condition
TASK 24-20-00-040-001-A
Check of the AC Main Generation Maintenance Condition
MMEL 24-22-01A
AC MAIN GENERATION (IDG, GCU, LINE CONTACTOR)
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 24-20-00-860-050-A
Subtask 24-20-00-210-054-B
Subtask 24-20-00-860-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:19:25 UTC
Check of the AC Main Generation Maintenance Condition
CAUTION:
IF THE IDG OPERATES IN THE DISCONNECTED MODE:
- DO NOT CONNECT IT AGAIN.
- MAKE SURE THAT THE IDG DOES NOT OPERATE FOR MORE THAN 50 HOURS IN THE DISCONNECTED MODE.
- AFTER A MAXIMUM OF 50 HOURS IN THE DISCONNECTED MODE, REPLACE IT AND SEND THE REMOVED IDG FOR A SHOP INSPECTION.
NOTE: The procedure is same for the IDG 1(2).
1. Reason for the JobMMEL 24-22-01A
AC MAIN GENERATION (IDG, GCU, LINE CONTACTOR)
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 49-00-00-860-005-A | APU Start by External Power |
| TASK 49-00-00-860-005-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-006-A | APU Shutdown by External Power |
| TASK 49-00-00-860-006-A-01 | APU Shutdown by Batteries |
| TASK 49-00-00-860-008-A | APU Start by External Power |
| TASK 49-00-00-860-008-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 49-90-00-600-004-A | Check Oil Level and Replenish (APS 3200) |
| TASK 49-90-00-600-007-A | Check Oil Level and Replenish (131-9(A)) |
Subtask 24-20-00-860-050-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
4. Procedure(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
Subtask 24-20-00-210-054-B
A. CAUTION to Prevent Damage to IDG
Subtask 24-20-00-040-051-C ** ON A/C NOT FOR ALL CAUTION:
REPLACE THE IDG1(2) BEFORE NEXT ENGINE START IF:
(1) On the lower ECAM DU, on the ELEC page, make sure that the IDG 1(2) DISC message is shown. - THE IDG1(2) WAS MECHANICALLY DISCONNECTED, AND
- THE FAULT MESSAGE "IDG1(E1-4000XU) OIL DELTA TEMP/GCU1 (1XU1)" OR "IDG2(E2-4000XU) OIL DELTA TEMP/GCU2 (1XU2)" IS THEN SHOWN ON THE PFR OR LAST LEG REPORT. THIS FAULT MESSAGE SHOWS THAT THE IDG IS STILL MECHANICALLY CONNECTED. THIS CAN CAUSE HEAVY DAMAGE TO THE IDG AT THE NEXT ENGINE START.
NOTE: This is only applicable if one generator is inoperative and the cause of the dispatch under MMEL 24-22-01A was one of these warning messages:
- ELEC IDG 1(2) OIL LO PR
- ELEC IDG 1(2) OIL OVHT.
B. Fuel recirculation Check
(1) On the ECAM control panel, push the STS key.
(2) On the lower ECAM display unit, make sure that the "ENG 1(2) FADEC" message does not come into view on the STATUS page.
(a) If the message comes into view for the engine with the IDG in operation:
Subtask 24-20-00-710-050-A ** ON A/C NOT FOR ALL (1) On the ECAM control panel, push the STS key.
(2) On the lower ECAM display unit, make sure that the "ENG 1(2) FADEC" message does not come into view on the STATUS page.
(a) If the message comes into view for the engine with the IDG in operation:
- Make sure that none of the messages that follow come into view:
. ACOC OIL TEMP TC/HC/EEC
. IDG OIL TEMP TC/HC/EEC
. ACOC AIR MOD VLV/HC/EEC
. FUEL DIV RET VLV/HC/EEC
. HMS FUEL OVTMP
. HMS ENG OIL OVTMP
. HMS IDG OIL OVTMP
. HMS IDG OVTMP W/RECIRC
. FUEL DIV RET VLV/EEC
- Release the ENG/FADEC GND PWR/1(2) pushbutton switch(es) (the ON legend(s) come(s) on).
C. Do this test:
Subtask 24-20-00-210-053-A | ACTION | RESULT |
|---|---|
| 1.On one MCDU, get the SYSTEM REPORT/TEST ENG menu page. | |
2.On the MCDU, on the ENG menu page:
| On the MCDU:
|
3.On the FADEC 1A(2A) page:
| On the MCDU:
|
4.On the MCDU:
| |
5.On the MCDU, on the ENG menu page:
| On the MCDU:
|
6.On the FADEC 1B(2B) page:
| On the MCDU:
|
7.On the MCDU:
| |
D. Check of the APU Oil Consumption
(1) If you do a regular monitoring of the APU oil consumption, make sure that the APU oil quantity is sufficient for the flight:
(a) Make sure that APU LOW OIL LEVEL indication is not shown:
1 On the ECAM control panel, push the APU key (on the lower ECAM DU, the APU page comes into view).
2 Make sure that the APU LOW OIL LEVEL indication is not shown.
(b) Make sure that there are no oil leaks:
1 Start and operate the APU:
Subtask 24-20-00-710-056-B ** ON A/C NOT FOR ALL (1) If you do a regular monitoring of the APU oil consumption, make sure that the APU oil quantity is sufficient for the flight:
- For the GTCP 36-300
or - For the APS 3200
or - For the 131-9(A)
(a) Make sure that APU LOW OIL LEVEL indication is not shown:
1 On the ECAM control panel, push the APU key (on the lower ECAM DU, the APU page comes into view).
2 Make sure that the APU LOW OIL LEVEL indication is not shown.
(b) Make sure that there are no oil leaks:
1 Start and operate the APU:
- For the GTCP 36-300 (Ref. AMM D/O 49-00-00-86), or
- For the APS 3200 (Ref. AMM TASK 49-00-00-860-005), or
- For the 131-9(A) (Ref. AMM TASK 49-00-00-860-008).
- Do a check for oil smell in the passenger compartment.
- Do a check for white smoke from the APU exhaust.
NOTE: An oil smell in the passenger compartment shows that there is an internal and/or external oil leakage.
NOTE: Smoke from APU exhaust shows that there is an internal oil leakage.
3 Stop the APU: - For the GTCP 36-300 (Ref. AMM D/O 49-00-00-86), or
- For the APS 3200 (Ref. AMM TASK 49-00-00-860-006), or
- For the 131-9(A) (Ref. AMM TASK 49-00-00-860-009).
- For the GTCP 36-300 (Ref. AMM D/O 49-90-00-60) , or
- For the APS 3200 (Ref. AMM TASK 49-90-00-600-004), or
- For the 131-9(A) (Ref. AMM TASK 49-90-00-600-007).
NOTE: During the oil level check, make sure that there is no external oil leakage in the APU compartment.
E. Check of the IDG Heat-Exchanger Bypass-Valves
(1) Make sure that the messages that follow are not shown on the last PFR leg:
5. Close-up(1) Make sure that the messages that follow are not shown on the last PFR leg:
- IDG 1(2) COOLER BYPASS VALVE
- IDG 1(2) (E1(2)-4000XU)/IDG 1(2) COOLER BYPASS VALVE.
Subtask 24-20-00-860-051-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the panel 50VU:
(Ref. AMM TASK 31-60-00-860-002).
(3) Make an entry in the logbook to show that the IDG is connected or disconnected.
(4) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 24-20-00-860-051-B ** ON A/C NOT FOR ALL (1) On the panel 50VU:
- push the ENG/FADEC GND PWR/1(2) pushbutton switch(es) (the ON legend(s) go(es) off).
(Ref. AMM TASK 31-60-00-860-002).
(3) Make an entry in the logbook to show that the IDG is connected or disconnected.
(4) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
A. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) Make an entry in the logbook to show that the IDG is connected or disconnected.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) Make an entry in the logbook to show that the IDG is connected or disconnected.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Oil Consumption of the APU GTCP 36-300