Installation of the Connection Box
TASK 23-73-42-400-001-A
Installation of the Connection Box
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-73-42-860-050-C ** ON A/C NOT FOR ALL
Subtask 23-73-42-420-050-A ** ON A/C NOT FOR ALL
Subtask 23-73-42-410-050-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:12:34 UTC
Installation of the Connection Box
FIN: 208RH1 ** ON A/C NOT FOR ALL
FIN: 208RH10 ** ON A/C NOT FOR ALL
FIN: 208RH11 ** ON A/C NOT FOR ALL
FIN: 208RH12 ** ON A/C NOT FOR ALL
FIN: 208RH13 ** ON A/C NOT FOR ALL
FIN: 208RH14 ** ON A/C NOT FOR ALL
FIN: 208RH2 ** ON A/C NOT FOR ALL
FIN: 208RH3 ** ON A/C NOT FOR ALL
FIN: 208RH4 ** ON A/C NOT FOR ALL
FIN: 208RH5 ** ON A/C NOT FOR ALL
FIN: 208RH6 ** ON A/C NOT FOR ALL
FIN: 208RH7 ** ON A/C NOT FOR ALL
FIN: 208RH8 ** ON A/C NOT FOR ALL
FIN: 208RH9 ** ON A/C NOT FOR ALL
FIN: 308RH1 ** ON A/C NOT FOR ALL
FIN: 308RH2 ** ON A/C NOT FOR ALL
FIN: 308RH3 ** ON A/C NOT FOR ALL
FIN: 308RH4 ** ON A/C NOT FOR ALL
FIN: 308RH5 ** ON A/C NOT FOR ALL
FIN: 308RH6 ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 208RH10 ** ON A/C NOT FOR ALL
FIN: 208RH11 ** ON A/C NOT FOR ALL
FIN: 208RH12 ** ON A/C NOT FOR ALL
FIN: 208RH13 ** ON A/C NOT FOR ALL
FIN: 208RH14 ** ON A/C NOT FOR ALL
FIN: 208RH2 ** ON A/C NOT FOR ALL
FIN: 208RH3 ** ON A/C NOT FOR ALL
FIN: 208RH4 ** ON A/C NOT FOR ALL
FIN: 208RH5 ** ON A/C NOT FOR ALL
FIN: 208RH6 ** ON A/C NOT FOR ALL
FIN: 208RH7 ** ON A/C NOT FOR ALL
FIN: 208RH8 ** ON A/C NOT FOR ALL
FIN: 208RH9 ** ON A/C NOT FOR ALL
FIN: 308RH1 ** ON A/C NOT FOR ALL
FIN: 308RH2 ** ON A/C NOT FOR ALL
FIN: 308RH3 ** ON A/C NOT FOR ALL
FIN: 308RH4 ** ON A/C NOT FOR ALL
FIN: 308RH5 ** ON A/C NOT FOR ALL
FIN: 308RH6 ** ON A/C NOT FOR ALL
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | STEPLADDER 0.5 M (1.6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [208RH1] (DEU CONNECTION BOX) | |
| FOR [208RH2] (DEU CONNECTION BOX) | |
| 231JW, 232JW | |
| FOR [208RH10] (DEU CONNECTION BOX) | |
| FOR [208RH9] (DEU CONNECTION BOX) | |
| 241WW, 242WW | |
| FOR [208RH11] (DEU CONNECTION BOX) | |
| FOR [208RH12] (DEU CONNECTION BOX) | |
| 251FW, 252FW | |
| 251MC | |
| FOR [208RH13] (DEU CONNECTION BOX) | |
| FOR [208RH14] (DEU CONNECTION BOX) | |
| 251TW, 252TW | |
| 251QW, 252QW | |
| FOR [208RH3] (DEU CONNECTION BOX) | |
| FOR [208RH4] (DEU CONNECTION BOX) | |
| 231WW, 232WW | |
| FOR [208RH5] (DEU CONNECTION BOX) | |
| FOR [208RH6] (DEU CONNECTION BOX) | |
| 231LC | |
| FOR [208RH7] (DEU CONNECTION BOX) | |
| FOR [208RH8] (DEU CONNECTION BOX) | |
| 241QW, 242QW | |
| 231XX, 232XX | |
| FOR [308RH1] (DEU CONNECTION BOX) | |
| FOR [308RH2] (DEU CONNECTION BOX) | |
| 221BC, 222BC | |
| FOR [308RH3] (DEU CONNECTION BOX) | |
| FOR [308RH4] (DEU CONNECTION BOX) | |
| 231JC | |
| FOR [308RH5] (DEU CONNECTION BOX) | |
| FOR [308RH6] (DEU CONNECTION BOX) | |
| 241WW, 242WW | |
| 251KC | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 23-73-00-740-005-B | Interface and Power-Up Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| TASK 23-73-00-861-001-A | Energize the Cabin Intercommunication Data System (CIDS) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 26-10-00-740-801-A | BITE Test of the Smoke Detection Function - System Test |
| ASM 237305 | |
| ASM 237321 | |
| FOR [208RH1] (DEU CONNECTION BOX) | |
| FOR [208RH2] (DEU CONNECTION BOX) | |
| TASK 25-23-48-000-001-A | Removal of the Cove Light Panel |
| TASK 25-23-48-400-001-A | Installation of the Cove Light Panel |
| FOR [208RH10] (DEU CONNECTION BOX) | |
| FOR [208RH9] (DEU CONNECTION BOX) | |
| TASK 25-23-48-000-001-A | Removal of the Cove Light Panel |
| TASK 25-23-48-400-001-A | Installation of the Cove Light Panel |
| FOR [208RH11] (DEU CONNECTION BOX) | |
| FOR [208RH12] (DEU CONNECTION BOX) | |
| TASK 25-23-41-000-001-A | Removal of the Ceiling Panels |
| TASK 25-23-41-400-001-A | Installation of the Ceiling Panels |
| TASK 25-23-48-000-001-A | Removal of the Cove Light Panel |
| TASK 25-23-48-400-001-A | Installation of the Cove Light Panel |
| FOR [208RH13] (DEU CONNECTION BOX) | |
| FOR [208RH14] (DEU CONNECTION BOX) | |
| TASK 25-23-48-000-001-A | Removal of the Cove Light Panel |
| TASK 25-23-48-400-001-A | Installation of the Cove Light Panel |
| FOR [208RH3] (DEU CONNECTION BOX) | |
| FOR [208RH4] (DEU CONNECTION BOX) | |
| TASK 25-23-48-000-001-A | Removal of the Cove Light Panel |
| TASK 25-23-48-400-001-A | Installation of the Cove Light Panel |
| FOR [208RH5] (DEU CONNECTION BOX) | |
| FOR [208RH6] (DEU CONNECTION BOX) | |
| TASK 25-23-41-000-001-A | Removal of the Ceiling Panels |
| TASK 25-23-41-400-001-A | Installation of the Ceiling Panels |
| FOR [208RH7] (DEU CONNECTION BOX) | |
| FOR [208RH8] (DEU CONNECTION BOX) | |
| TASK 25-23-48-000-001-A | Removal of the Cove Light Panel |
| TASK 25-23-48-400-001-A | Installation of the Cove Light Panel |
| FOR [308RH1] (DEU CONNECTION BOX) | |
| FOR [308RH2] (DEU CONNECTION BOX) | |
| TASK 25-23-42-000-001-A | Removal of the Ceiling Panels - Forward Utility Area |
| TASK 25-23-42-400-001-A | Installation of the Ceiling Panels - Forward Utility Area |
| FOR [308RH3] (DEU CONNECTION BOX) | |
| FOR [308RH4] (DEU CONNECTION BOX) | |
| TASK 25-23-41-000-001-A | Removal of the Ceiling Panels |
| TASK 25-23-41-400-001-A | Installation of the Ceiling Panels |
| FOR [308RH5] (DEU CONNECTION BOX) | |
| FOR [308RH6] (DEU CONNECTION BOX) | |
| TASK 25-23-41-000-001-A | Removal of the Ceiling Panels |
| TASK 25-23-41-400-001-A | Installation of the Ceiling Panels |
| TASK 25-23-48-000-001-A | Removal of the Cove Light Panel |
| TASK 25-23-48-400-001-A | Installation of the Cove Light Panel |
Subtask 23-73-42-860-050-C ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
(1) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
(2) Make sure that the forward utility area - ceiling panel is removed:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Remove 221BC and 222BC (Ref. AMM TASK 25-23-42-000-001).
(3) Make sure that the related cove light and ceiling panels are removed:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Remove 231JW and 232JW (Ref. AMM TASK 25-23-48-000-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Remove 231WW and 232WW (Ref. AMM TASK 25-23-48-000-001).
(c) FOR [308RH3] (DEU CONNECTION BOX), [308RH4] (DEU CONNECTION BOX)
Remove 231JC (Ref. AMM TASK 25-23-41-000-001).
(d) FOR [208RH5] (DEU CONNECTION BOX), [208RH6] (DEU CONNECTION BOX)
Remove 231LC (Ref. AMM TASK 25-23-41-000-001).
(e) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Remove 231XX and 232XX (Ref. AMM TASK 25-23-48-000-001).
(f) FOR [208RH9] (DEU CONNECTION BOX), [208RH10] (DEU CONNECTION BOX)
Remove 241WW and 242WW (Ref. AMM TASK 25-23-48-000-001).
(g) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Remove 251KC (Ref. AMM TASK 25-23-41-000-001).
(h) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Remove 251MC (Ref. AMM TASK 25-23-41-000-001).
(i) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Remove 251QW and 252QW (Ref. AMM TASK 25-23-48-000-001).
Subtask 23-73-42-860-050-D ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-41-00-861-002)
(1) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
(2) Make sure that the forward utility area - ceiling panel is removed:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Remove 221BC and 222BC (Ref. AMM TASK 25-23-42-000-001).
(3) Make sure that the related cove light and ceiling panels are removed:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Remove 231JW and 232JW (Ref. AMM TASK 25-23-48-000-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Remove 231WW and 232WW (Ref. AMM TASK 25-23-48-000-001).
(c) FOR [308RH3] (DEU CONNECTION BOX), [308RH4] (DEU CONNECTION BOX)
Remove 231JC (Ref. AMM TASK 25-23-41-000-001).
(d) FOR [208RH5] (DEU CONNECTION BOX), [208RH6] (DEU CONNECTION BOX)
Remove 231LC (Ref. AMM TASK 25-23-41-000-001).
(e) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Remove 231XX and 232XX (Ref. AMM TASK 25-23-48-000-001).
(f) FOR [208RH9] (DEU CONNECTION BOX), [208RH10] (DEU CONNECTION BOX)
Remove 241WW and 242WW (Ref. AMM TASK 25-23-48-000-001).
(g) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Remove 251KC (Ref. AMM TASK 25-23-41-000-001).
(h) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Remove 251MC (Ref. AMM TASK 25-23-41-000-001).
(i) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Remove 251QW and 252QW (Ref. AMM TASK 25-23-48-000-001).
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-42-00-861-001)
(1) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
(2) Make sure that the forward utility area - ceiling panel is removed:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Remove 221BC and 222BC (Ref. AMM TASK 25-23-42-000-001).
(3) Make sure that the related cove light panels are removed:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Remove 231JW and 232JW (Ref. AMM TASK 25-23-48-000-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Remove 231WW and 232WW (Ref. AMM TASK 25-23-48-000-001).
(c) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Remove 241QW and 242QW (Ref. AMM TASK 25-23-48-000-001).
(d) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Remove 241WW and 242WW (Ref. AMM TASK 25-23-48-000-001).
(e) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Remove 251FW and 252FW (Ref. AMM TASK 25-23-48-000-001).
(f) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Remove 251TW and 252TW (Ref. AMM TASK 25-23-48-000-001).
Subtask 23-73-42-860-050-E ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-42-00-861-001)
(1) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
(2) Make sure that the forward utility area - ceiling panel is removed:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Remove 221BC and 222BC (Ref. AMM TASK 25-23-42-000-001).
(3) Make sure that the related cove light panels are removed:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Remove 231JW and 232JW (Ref. AMM TASK 25-23-48-000-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Remove 231WW and 232WW (Ref. AMM TASK 25-23-48-000-001).
(c) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Remove 241QW and 242QW (Ref. AMM TASK 25-23-48-000-001).
(d) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Remove 241WW and 242WW (Ref. AMM TASK 25-23-48-000-001).
(e) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Remove 251FW and 252FW (Ref. AMM TASK 25-23-48-000-001).
(f) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Remove 251TW and 252TW (Ref. AMM TASK 25-23-48-000-001).
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-42-00-861-001)
(1) Make sure that the EMER EXIT LT switch 4WL on the overhead panel 25VU is in the OFF position.
(2) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
(3) Make sure that the forward utility area - ceiling panel is removed:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Remove 221BC and 222BC (Ref. AMM TASK 25-23-42-000-001).
(4) Make sure that the related cove light panels are removed:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Remove 231JW and 232JW (Ref. AMM TASK 25-23-48-000-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Remove 231WW and 232WW (Ref. AMM TASK 25-23-48-000-001).
(c) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Remove 241QW and 242QW (Ref. AMM TASK 25-23-48-000-001).
(d) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Remove 241WW and 242WW (Ref. AMM TASK 25-23-48-000-001).
(e) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Remove 251FW and 252FW (Ref. AMM TASK 25-23-48-000-001).
(f) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Remove 251TW and 252TW (Ref. AMM TASK 25-23-48-000-001).
Subtask 23-73-42-860-050-H ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-42-00-861-001)
(1) Make sure that the EMER EXIT LT switch 4WL on the overhead panel 25VU is in the OFF position.
(2) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
(3) Make sure that the forward utility area - ceiling panel is removed:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Remove 221BC and 222BC (Ref. AMM TASK 25-23-42-000-001).
(4) Make sure that the related cove light panels are removed:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Remove 231JW and 232JW (Ref. AMM TASK 25-23-48-000-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Remove 231WW and 232WW (Ref. AMM TASK 25-23-48-000-001).
(c) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Remove 241QW and 242QW (Ref. AMM TASK 25-23-48-000-001).
(d) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Remove 241WW and 242WW (Ref. AMM TASK 25-23-48-000-001).
(e) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Remove 251FW and 252FW (Ref. AMM TASK 25-23-48-000-001).
(f) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Remove 251TW and 252TW (Ref. AMM TASK 25-23-48-000-001).
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
(1) Make sure that the EMER EXIT LT switch 4WL on the overhead panel 25VU is in the OFF position.
(2) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
(3) Make sure that the forward utility area - ceiling panel is removed:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Remove 221BC and 222BC (Ref. AMM TASK 25-23-42-000-001).
(4) Make sure that the related cove light and ceiling panels are removed:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Remove 231JW and 232JW (Ref. AMM TASK 25-23-48-000-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Remove 231WW and 232WW (Ref. AMM TASK 25-23-48-000-001).
(c) FOR [308RH3] (DEU CONNECTION BOX), [308RH4] (DEU CONNECTION BOX)
remove 231JC (Ref. AMM TASK 25-23-41-000-001).
(d) FOR [208RH5] (DEU CONNECTION BOX), [208RH6] (DEU CONNECTION BOX)
Remove 231LC (Ref. AMM TASK 25-23-41-000-001).
(e) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Remove 231XX and 232XX (Ref. AMM TASK 25-23-48-000-001).
(f) FOR [208RH9] (DEU CONNECTION BOX), [208RH10] (DEU CONNECTION BOX)
Remove 241WW and 242WW (Ref. AMM TASK 25-23-48-000-001).
(g) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Remove 251KC (Ref. AMM TASK 25-23-41-000-001).
(h) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Remove 251MC (Ref. AMM TASK 25-23-41-000-001).
(i) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Remove 251QW and 252QW (Ref. AMM TASK 25-23-48-000-001).
Subtask 23-73-42-865-051-A ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-41-00-861-002)
(1) Make sure that the EMER EXIT LT switch 4WL on the overhead panel 25VU is in the OFF position.
(2) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
(3) Make sure that the forward utility area - ceiling panel is removed:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Remove 221BC and 222BC (Ref. AMM TASK 25-23-42-000-001).
(4) Make sure that the related cove light and ceiling panels are removed:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Remove 231JW and 232JW (Ref. AMM TASK 25-23-48-000-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Remove 231WW and 232WW (Ref. AMM TASK 25-23-48-000-001).
(c) FOR [308RH3] (DEU CONNECTION BOX), [308RH4] (DEU CONNECTION BOX)
remove 231JC (Ref. AMM TASK 25-23-41-000-001).
(d) FOR [208RH5] (DEU CONNECTION BOX), [208RH6] (DEU CONNECTION BOX)
Remove 231LC (Ref. AMM TASK 25-23-41-000-001).
(e) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Remove 231XX and 232XX (Ref. AMM TASK 25-23-48-000-001).
(f) FOR [208RH9] (DEU CONNECTION BOX), [208RH10] (DEU CONNECTION BOX)
Remove 241WW and 242WW (Ref. AMM TASK 25-23-48-000-001).
(g) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Remove 251KC (Ref. AMM TASK 25-23-41-000-001).
(h) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Remove 251MC (Ref. AMM TASK 25-23-41-000-001).
(i) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Remove 251QW and 252QW (Ref. AMM TASK 25-23-48-000-001).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DEU B/ESS | 153RH | G03 |
| 49VU | COM/CIDS/DEU A ESS/AFT R | 172RH | HA12 |
| 49VU | COM/CIDS/DEU A ESS/AFT L | 179RH | HA11 |
| 49VU | COM/CIDS/DEU A ESS/FWD R | 158RH | HA10 |
| 49VU | COM/CIDS/DEU A ESS/FWD L | 159RH | HA09 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM / CIDS / DEU A ESS / MID R | 196RH | G05 |
| 49VU | COM / CIDS / DEU A ESS / MID L | 195RH | G04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DEU B ESS/R | 420RH | G05 |
| 49VU | COM/CIDS/DEU B ESS/L | 419RH | G04 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU A NORM/R AFT | 168RH | M12 |
| 121VU | COM NAV/CIDS/DEU A NORM/L AFT | 167RH | M11 |
| 121VU | COM NAV/CIDS/DEU A NORM/R FWD | 164RH | M10 |
| 121VU | COM NAV/CIDS/DEU A NORM/L FWD | 163RH | M09 |
| 121VU | COM NAV/CIDS/DEU B/NORM | 162RH | M08 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU A NORM/R FWD | 164RH | M11 |
| 121VU | COM NAV/CIDS/DEU A NORM/L FWD | 163RH | M10 |
| 121VU | COM / CIDS / DEU B / NORM FWD | 193RH | M09 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU B NORM/R | 620RH | M08 |
| 121VU | COM NAV/CIDS/DEU B NORM/L | 619RH | M07 |
| 121VU | COM/CIDS/DEU B BAT/R | 720RH | Q11 |
| 121VU | COM/CIDS/DEU B BAT/L | 719RH | Q10 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/DEU A BAT/FWD R | 258RH | N14 |
| 121VU | COM/CIDS/DEU A BAT/L FWD | 259RH | N13 |
| 121VU | COM/CIDS/DEU B/BAT | 143RH | N12 |
| 121VU | COM/CIDS/DEU A BAT/AFT R | 272RH | Q11 |
| 121VU | COM/CIDS/DEU A BAT/AFT L | 279RH | Q10 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | DEU A BAT MID R | 296RH | M13 |
| 121VU | DEU A BAT MID L | 295RH | M12 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | CIDS-DEU B-NORM-AFT | 194RH | C08 |
| 2001VU | CIDS-DEU A NORM-AFT-RH | 174RH | C07 |
| 2001VU | CIDS-DEU A NORM-AFT-LH | 173RH | C06 |
| 2001VU | CIDS-DEU A NORM-MID-RH | 198RH | C05 |
| 2001VU | CIDS-DEU A NORM-MID-LH | 197RH | C04 |
Subtask 23-73-42-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Connection Box
Connection Box DEU Type A/B - Component Location ** ON A/C NOT FOR ALL
Connection Box DEU Type A/B - Component Location ** ON A/C NOT FOR ALL
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Connect the connection box (3) to the decoder/encoder unit (1) and tighten the nylatches (4).
(4) Remove the CAP-BLANKING from each electrical connector and receptacle.
(5) Make sure that all the electrical connections are clean and in the correct condition.
(6) Make sure that the coding switches are in the positions recorded during the removal procedure. For the correct position of the DEU coding switches, please refer to ASM 237305 ASM 237321.
(8) Safety the electrical connector (2)
Subtask 23-73-42-865-052-A ** ON A/C NOT FOR ALL
Connection Box DEU Type A/B - Component Location ** ON A/C NOT FOR ALL
Connection Box DEU Type A/B - Component Location ** ON A/C NOT FOR ALL (2) Do an inspection of the component interfaces and the adjacent area.
(3) Connect the connection box (3) to the decoder/encoder unit (1) and tighten the nylatches (4).
(4) Remove the CAP-BLANKING from each electrical connector and receptacle.
(5) Make sure that all the electrical connections are clean and in the correct condition.
(6) Make sure that the coding switches are in the positions recorded during the removal procedure. For the correct position of the DEU coding switches, please refer to ASM 237305 ASM 237321.
NOTE: It is mandatory to set the position of the coding switches correctly. An incorrect position of the coding switches causes incorrect CIDS operation. Because of this, there can be fault messages related to the CIDS and/or the related DEU. When there are no fault messages you cannot be sure that all coding switches are in the correct position.
(7) Connect the electrical connector (2) to the connection box (3). (8) Safety the electrical connector (2)
CAUTION:
MAKE SURE THAT THE SPRING LATCHES CORRECTLY HOLD THE CONNECTOR IN THE FULLY ENGAGED POSITION. THE SPRING LATCHES PREVENT UNWANTED MOVEMENT OF THE CONNECTOR, AND THUS THE RISK OF ARCING, WHICH CAN CAUSE DAMAGE TO THE UNIT.
(a) Safety the connector (2) with the spring latches (5). B. Remove the safety clips and tags and close these circuit breakers in this sequence:
Subtask 23-73-42-869-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | CIDS-DEU A NORM-MID-RH | 198RH | C05 |
| 2001VU | CIDS-DEU A NORM-MID-LH | 197RH | C04 |
| 2001VU | CIDS-DEU B-NORM-AFT | 194RH | C08 |
| 121VU | COM / CIDS / DEU B / NORM FWD | 193RH | M09 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU B NORM/L | 619RH | M07 |
| 121VU | COM NAV/CIDS/DEU B NORM/R | 620RH | M08 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | CIDS-DEU A NORM-AFT-RH | 174RH | C07 |
| 2001VU | CIDS-DEU A NORM-AFT-LH | 173RH | C06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU A NORM/R AFT | 168RH | M12 |
| 121VU | COM NAV/CIDS/DEU A NORM/L AFT | 167RH | M11 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU A NORM/R FWD | 164RH | M11 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU A NORM/R FWD | 164RH | M10 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU A NORM/L FWD | 163RH | M10 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU A NORM/L FWD | 163RH | M09 |
| 121VU | COM NAV/CIDS/DEU B/NORM | 162RH | M08 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM / CIDS / DEU A ESS / MID R | 196RH | G05 |
| 49VU | COM / CIDS / DEU A ESS / MID L | 195RH | G04 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DEU A ESS/AFT L | 179RH | HA11 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/DEU A BAT/AFT R | 272RH | Q11 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DEU A ESS/FWD L | 159RH | HA09 |
| 49VU | COM/CIDS/DEU A ESS/FWD R | 158RH | HA10 |
| 49VU | COM/CIDS/DEU B/ESS | 153RH | G03 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DEU B ESS/L | 419RH | G04 |
| 49VU | COM/CIDS/DEU B ESS/R | 420RH | G05 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | DEU A BAT MID R | 296RH | M13 |
| 121VU | DEU A BAT MID L | 295RH | M12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/DEU A BAT/AFT L | 279RH | Q10 |
| 121VU | COM/CIDS/DEU A BAT/AFT R | 272RH | Q11 |
| 121VU | COM/CIDS/DEU A BAT/L FWD | 259RH | N13 |
| 121VU | COM/CIDS/DEU A BAT/FWD R | 258RH | N14 |
| 121VU | COM/CIDS/DEU B/BAT | 143RH | N12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/DEU B BAT/L | 719RH | Q10 |
| 121VU | COM/CIDS/DEU B BAT/R | 720RH | Q11 |
C. Aircraft Maintenance Configuration
(1) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
(2) Do the interface and power-up test of the CIDS (Ref. AMM TASK 23-73-00-740-005).
Subtask 23-73-42-740-050-A ** ON A/C NOT FOR ALL 5. Close-up(1) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
(2) Do the interface and power-up test of the CIDS (Ref. AMM TASK 23-73-00-740-005).
Subtask 23-73-42-410-050-B ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the forward utility area - ceiling panel:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Install 221BC and 222BC (Ref. AMM TASK 25-23-42-400-001).
(3) Install the related cove light and ceiling panels:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Install 231JW and 232JW (Ref. AMM TASK 25-23-48-400-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Install 231WW and 232WW (Ref. AMM TASK 25-23-48-400-001).
(c) FOR [308RH3] (DEU CONNECTION BOX), [308RH4] (DEU CONNECTION BOX)
Install 231JC (Ref. AMM TASK 25-23-41-400-001).
(d) FOR [208RH5] (DEU CONNECTION BOX), [208RH6] (DEU CONNECTION BOX)
Install 231LC (Ref. AMM TASK 25-23-41-400-001).
(e) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Install 231XX and 232XX (Ref. AMM TASK 25-23-48-400-001).
(f) FOR [208RH9] (DEU CONNECTION BOX), [208RH10] (DEU CONNECTION BOX)
Install 241WW and 242WW (Ref. AMM TASK 25-23-48-400-001).
(g) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Install 251KC (Ref. AMM TASK 25-23-41-400-001).
(h) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Install 251MC (Ref. AMM TASK 25-23-41-400-001).
(i) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Install 251QW and 252QW (Ref. AMM TASK 25-23-48-400-001).
(4) Remove the STEPLADDER 0.5 M (1.6 FT).
Subtask 23-73-42-410-050-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the forward utility area - ceiling panel:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Install 221BC and 222BC (Ref. AMM TASK 25-23-42-400-001).
(3) Install the related cove light and ceiling panels:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Install 231JW and 232JW (Ref. AMM TASK 25-23-48-400-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Install 231WW and 232WW (Ref. AMM TASK 25-23-48-400-001).
(c) FOR [308RH3] (DEU CONNECTION BOX), [308RH4] (DEU CONNECTION BOX)
Install 231JC (Ref. AMM TASK 25-23-41-400-001).
(d) FOR [208RH5] (DEU CONNECTION BOX), [208RH6] (DEU CONNECTION BOX)
Install 231LC (Ref. AMM TASK 25-23-41-400-001).
(e) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Install 231XX and 232XX (Ref. AMM TASK 25-23-48-400-001).
(f) FOR [208RH9] (DEU CONNECTION BOX), [208RH10] (DEU CONNECTION BOX)
Install 241WW and 242WW (Ref. AMM TASK 25-23-48-400-001).
(g) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Install 251KC (Ref. AMM TASK 25-23-41-400-001).
(h) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Install 251MC (Ref. AMM TASK 25-23-41-400-001).
(i) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Install 251QW and 252QW (Ref. AMM TASK 25-23-48-400-001).
(4) Remove the STEPLADDER 0.5 M (1.6 FT).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the forward utility area - ceiling panel:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Install 221BC and 222BC (Ref. AMM TASK 25-23-42-400-001).
(3) Install the related cove light panels:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Install 231JW and 232JW (Ref. AMM TASK 25-23-48-400-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Install 231WW and 232WW (Ref. AMM TASK 25-23-48-400-001).
(c) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Install 241QW and 242QW (Ref. AMM TASK 25-23-48-400-001).
(d) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Install 241WW and 242WW (Ref. AMM TASK 25-23-48-400-001).
(e) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Install 251FW and 252FW (Ref. AMM TASK 25-23-48-400-001).
(f) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Install 251TW and 252TW (Ref. AMM TASK 25-23-48-400-001).
(4) Remove the STEPLADDER 0.5 M (1.6 FT).
Subtask 23-73-42-862-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the forward utility area - ceiling panel:
(a) FOR [308RH1] (DEU CONNECTION BOX), [308RH2] (DEU CONNECTION BOX)
Install 221BC and 222BC (Ref. AMM TASK 25-23-42-400-001).
(3) Install the related cove light panels:
(a) FOR [208RH1] (DEU CONNECTION BOX), [208RH2] (DEU CONNECTION BOX)
Install 231JW and 232JW (Ref. AMM TASK 25-23-48-400-001).
(b) FOR [208RH3] (DEU CONNECTION BOX), [208RH4] (DEU CONNECTION BOX)
Install 231WW and 232WW (Ref. AMM TASK 25-23-48-400-001).
(c) FOR [208RH7] (DEU CONNECTION BOX), [208RH8] (DEU CONNECTION BOX)
Install 241QW and 242QW (Ref. AMM TASK 25-23-48-400-001).
(d) FOR [308RH5] (DEU CONNECTION BOX), [308RH6] (DEU CONNECTION BOX)
Install 241WW and 242WW (Ref. AMM TASK 25-23-48-400-001).
(e) FOR [208RH11] (DEU CONNECTION BOX), [208RH12] (DEU CONNECTION BOX)
Install 251FW and 252FW (Ref. AMM TASK 25-23-48-400-001).
(f) FOR [208RH13] (DEU CONNECTION BOX), [208RH14] (DEU CONNECTION BOX)
Install 251TW and 252TW (Ref. AMM TASK 25-23-48-400-001).
(4) Remove the STEPLADDER 0.5 M (1.6 FT).