W DOC AIRBUS | AMM A320F

Installation of the Pax Call Switch-Card


TASK 23-73-38-400-802-A
Installation of the Pax Call Switch-Card


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 23-73-45-400-001-A
Installation of the Passenger Service Unit
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 23-73-38-861-057-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
4. Procedure
Subtask 23-73-38-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the Pax Call Switch-Card
   (1) If necessary, remove the drip water cover (2):
     (a) Pull out the two locking tabs (3) at the side of the drip water cover.
     (b) Lift and remove the drip water cover (2).
   (2) Carefully put the first plastic catch into the corresponding hole (5) of the pax call switch-card (4).
   (3) Carefully put the second plastic catch into the corresponding hole (5).
   (4) Make sure that you do not push the second plastic catch too much to prevent damage to the Power Supply Unit (PSU).
   (5) Make sure that the two plastic catches lock correctly.
   (6) Connect and lock the related connector (6) to the card socket (10).
   (7) Repeat steps 2 thru 6 for each pax call switch-card (4).
   (8) Carefully put the drip water cover (2) in its original position.
   (9) Lock the two locking tabs (3) at the sides of the drip water cover (2).
   (10) Install the PSU (1). (Ref. AMM TASK 23-73-45-400-001)
   (11) Make sure that the work area is clean and clear of tools and other items.
Subtask 23-73-38-865-072-A
DELETED
5. Close-up
Subtask 23-73-38-862-054-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
[Rev.10 from 2021] 2026.04.02 06:51:51 UTC