Removal of the Additional Attendant Panel
TASK 23-73-13-000-001-A
Removal of the Additional Attendant Panel
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-73-13-861-050-A
Subtask 23-73-13-020-050-A
[Rev.10 from 2021]
2026.03.31 23:17:48 UTC
Removal of the Additional Attendant Panel
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 23-73-00-00 | CABIN INTERCOMMUNICATION DATA SYSTEM (CIDS) - DESCRIPTION AND OPERATION |
| TASK 23-73-00-00-01 | CABIN INTERCOMMUNICATION DATA SYSTEM (CIDS) - DESCRIPTION AND OPERATION |
Subtask 23-73-13-861-050-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
For the location of this component, refer to paragraph Component Location
(Ref. AMM D/O 23-73-00-00).
Subtask 23-73-13-865-050-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
For the location of this component, refer to paragraph Component Location
(Ref. AMM D/O 23-73-00-00).
B. Open, safety and tag these circuit breakers in this sequence:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/DEU B/BAT | 143RH | N12 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DEU B/ESS | 153RH | G03 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU B/NORM | 162RH | M09 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DEU B/NORM | 162RH | M08 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM / CIDS / DEU B / NORM FWD | 193RH | M09 |
| 2001VU | CIDS-DEU B-NORM-AFT | 194RH | C08 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/DEU B BAT/L | 719RH | Q10 |
| 121VU | COM/CIDS/DEU B BAT/R | 720RH | Q11 |
| 49VU | COM/CIDS/DEU B ESS/L | 419RH | G04 |
| 49VU | COM/CIDS/DEU B ESS/R | 420RH | G05 |
| 121VU | COM NAV/CIDS/DEU B NORM/L | 619RH | M07 |
| 121VU | COM NAV/CIDS/DEU B NORM/R | 620RH | M08 |
Subtask 23-73-13-020-050-A
A. Removal of the Additional Attendant Panel (AAP)
(1) Remove the cover (1) from the AAP (2).
(2) Remove the screws (3) and the washers (4).
(3) Pull and lower the AAP (2) and disconnect the electrical connector (5).
(4) Remove the AAP (2).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(1) Remove the cover (1) from the AAP (2).
(2) Remove the screws (3) and the washers (4).
(3) Pull and lower the AAP (2) and disconnect the electrical connector (5).
(4) Remove the AAP (2).
(5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Additional Attendant Panel