Removal of the Light Module
TASK 23-73-12-000-003-A
Removal of the Light Module
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 23-73-12-861-054-A ** ON A/C NOT FOR ALL
Subtask 23-73-12-020-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:17:39 UTC
Removal of the Light Module
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 23-73-00-861-001-A | Energize the Cabin Intercommunication Data System (CIDS) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 31-32-00-860-003-A | Procedure to Get Access to the SYSTEM REPORT/TEST/COM Page |
Subtask 23-73-12-861-054-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 23-73-12-970-052-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Trouble Shooting Data
(1) Make sure that the Cabin Intercommunication Data System (CIDS) is energized (Ref. AMM TASK 23-73-00-861-001)
(2) If available, you can print the Trouble Shooting Data (TSD) as follows:
Subtask 23-73-12-865-056-A ** ON A/C NOT FOR ALL (1) Make sure that the Cabin Intercommunication Data System (CIDS) is energized (Ref. AMM TASK 23-73-00-861-001)
(2) If available, you can print the Trouble Shooting Data (TSD) as follows:
- get access to the SYSTEM REPORT/TEST COM page (Ref. AMM TASK 31-32-00-860-003)
- on this page, push the line key adjacent to the CIDS1 (2) indication.
- on the CIDS1 (2) page, push the line key adjacent to the TROUBLE SHOOTING DATA indication to get the TROUBLE SHOOTING DATA page.
- print the Trouble Shooting Data page.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM /CIDS/FWD ATTND/PNL | 170RH | Q14 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM /CIDS/FLT ATTND/PNL | 170RH | Q14 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/FAP1/NORM | 170RH | Q14 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/FWD ATTND/PNL | 170RH | Q14 |
Subtask 23-73-12-020-053-A ** ON A/C NOT FOR ALL
A. Removal of the light module
(1) Pull down the locking rod (1) and carefully open the Fwd Attendant Panel (FAP) door (2).
(2) Loosen the quick release fasteners (3) from the light module (4).
(3) Carefully pull the light module (4) until you can see the electrical connection (5).
(4) Disconnect the electrical connection (5).
(5) Remove the light module (4).
(1) Pull down the locking rod (1) and carefully open the Fwd Attendant Panel (FAP) door (2).
(2) Loosen the quick release fasteners (3) from the light module (4).
(3) Carefully pull the light module (4) until you can see the electrical connection (5).
(4) Disconnect the electrical connection (5).
(5) Remove the light module (4).
Light Module