W DOC AIRBUS | AMM A320F

Removal of the Area Call Panel


TASK 23-73-11-000-001-A
Removal of the Area Call Panel


ZONE: 200
FIN: 340RH1
FIN: 340RH10
FIN: 340RH13 ** ON A/C NOT FOR ALL
FIN: 340RH14 ** ON A/C NOT FOR ALL
FIN: 340RH2
FIN: 340RH7 ** ON A/C NOT FOR ALL
FIN: 340RH8 ** ON A/C NOT FOR ALL
FIN: 340RH9
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
STEPLADDER 1.0 M (3.3 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 23-73-00-00
CABIN INTERCOMMUNICATION DATA SYSTEM (CIDS) - DESCRIPTION AND OPERATION
TASK 23-73-00-00-01
CABIN INTERCOMMUNICATION DATA SYSTEM (CIDS) - DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 23-73-11-861-050-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) For the location of this component, refer to paragraph Component Location
(Ref. AMM D/O 23-73-00-00).
Subtask 23-73-11-865-050-A
B. Open, safety and tag these circuit breakers in this sequence:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUCOM/CIDS/DEU B/BAT143RHN12
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DEU B/ESS153RHG03
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B/NORM162RHM09
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B/NORM162RHM08
** ON A/C NOT FOR ALL
121VUCOM / CIDS / DEU B / NORM FWD193RHM09
2001VUCIDS-DEU B-NORM-AFT194RHC08
** ON A/C NOT FOR ALL
121VUCOM/CIDS/DEU B BAT/L719RHQ10
121VUCOM/CIDS/DEU B BAT/R720RHQ11
49VUCOM/CIDS/DEU B ESS/L419RHG04
49VUCOM/CIDS/DEU B ESS/R420RHG05
121VUCOM NAV/CIDS/DEU B NORM/L619RHM07
121VUCOM NAV/CIDS/DEU B NORM/R620RHM08
Subtask 23-73-11-941-050-A
C. Put the STEPLADDER 1.0 M (3.3 FT) in position below the related Area Call Panel.
4. Procedure
Subtask 23-73-11-020-050-A
A. Removal of the Area Call Panel (ACP)
   (1) Remove the lens (4) from the ACP (3).
   (2) Release the spring clips (1), pull and lower the ACP (3) until you can see the electrical connectors (2).
   (3) Make match marks on the components that you disconnect/remove to record their connections/positions. This is important for the subsequent installation procedure.
   (4) Disconnect the electrical connectors (2) and remove the ACP (3).
[Rev.10 from 2021] 2026.04.02 06:12:28 UTC