Removal of the Anti-Hijack-System Cameras
TASK 23-72-51-000-001-A
Removal of the Anti-Hijack-System Cameras
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-72-51-861-050-A ** ON A/C NOT FOR ALL Subtask 23-72-51-865-054-A ** ON A/C NOT FOR ALL
Subtask 23-72-51-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:16:25 UTC
Removal of the Anti-Hijack-System Cameras
ZONE: 210
ZONE: 220
FIN: 12RA ** ON A/C NOT FOR ALL
FIN: 13RA ** ON A/C NOT FOR ALL
FIN: 14RA ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 220
FIN: 12RA ** ON A/C NOT FOR ALL
FIN: 13RA ** ON A/C NOT FOR ALL
FIN: 14RA ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 220 | FWD CAB UTILITY AREAS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 25-23-42-000-001-A | Removal of the Ceiling Panels - Forward Utility Area |
Subtask 23-72-51-861-050-A ** ON A/C NOT FOR ALL Subtask 23-72-51-865-054-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | DOORS/CKPT/VIDEO/SPLY | 15RA | T16 |
Subtask 23-72-51-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Cameras
(2) Hold the camera (3) in position.
(3) Remove the screws (5) and the washers (6).
(4) Carefully remove the camera (3) with the adapter plate (2) until you can disconnect the electrical connector (1).
(5) Disconnect the electrical connector (1) and remove the camera (3) with the adapter plate (2).
(a) Loosely attach the camera (3) to the ceiling panel with the screws (5).
(b) Remove the ceiling panel and move it until you can get access to the electrical connector (1) (Ref. AMM TASK 25-23-42-000-001).
(c) Disconnect the electrical connector (1) from the camera (3).
(d) Remove the three screws (5) and remove the camera (3) with the adapter plate (2) from the ceiling panel.
(7) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
NOTE: The removal procedure for all the cameras is the same. Only one procedure is given.
(1) Remove the caps (4). (2) Hold the camera (3) in position.
(3) Remove the screws (5) and the washers (6).
(4) Carefully remove the camera (3) with the adapter plate (2) until you can disconnect the electrical connector (1).
(5) Disconnect the electrical connector (1) and remove the camera (3) with the adapter plate (2).
NOTE: Keep the adapter plate (2) with the camera (3) for the installation procedure.
(6) If you cannot get access to disconnect the electrical connector (1), do the subsequent steps: (a) Loosely attach the camera (3) to the ceiling panel with the screws (5).
(b) Remove the ceiling panel and move it until you can get access to the electrical connector (1) (Ref. AMM TASK 25-23-42-000-001).
(c) Disconnect the electrical connector (1) from the camera (3).
(d) Remove the three screws (5) and remove the camera (3) with the adapter plate (2) from the ceiling panel.
(7) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Cameras