W DOC AIRBUS | AMM A320F

Installation of the Cockpit-Door Surveillance-System Monitor


TASK 23-72-22-400-001-A
Installation of the Cockpit-Door Surveillance-System Monitor


ZONE: 212
FIN: 10RA ** ON A/C NOT FOR ALL
FIN: 10RAA ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
Torque wrench: range to between 0.339 and 0.282 m.daN (30.00 and 24.96 lbf.in ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
212
COCKPIT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 23-72-00-710-001-A
Operational Test of the Anti-Hijack Camera-Monitoring-System
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 23-72-22-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-41-00-861-002)
Subtask 23-72-22-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUDOORS/CKPT/VIDEO/SPLY15RAT16
4. Procedure
Subtask 23-72-22-710-052-A ** ON A/C NOT FOR ALL
A. Installation of the Monitor or Hinge Assembly:

   (1) If you want to install the monitor only:
  • Go to paragraph B.
   (2) If you want to install the hinge assembly only:
  • Go to paragraph C.
Subtask 23-72-22-420-053-A ** ON A/C NOT FOR ALL
B. Installation of the Monitor
   (1) Do a visual inspection of the component interface and/or the adjacent area.
   (2) Clean the component interface and/or the adjacent area.
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (4) Make sure that all the electrical connections are clean and in the correct condition.
   (5) Install the monitor (1) with the screws (3) on the hinge assembly (2).
   (6) TORQUE the screws (3) to between 0.339 and 0.282 m.daN (30.00 and 24.96 lbf.in ) T.
Subtask 23-72-22-420-054-A ** ON A/C NOT FOR ALL
C. Installation of the Hinge Assembly:
   (1) Do a visual inspection of the component interface and/or the adjacent area.
   (2) Clean the component interface and/or the adjacent area.
   (3) Put the hinge assembly (1) in its installation position.
   (4) Install the washers (4) and the screws (5) in the mounting plate (3).
   (5) Install the washer (6) and the screw (7) in the mounting plate (3).
   (6) Tighten the screws (5) and (7).
   (7) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (8) Make sure that all the electrical connections are clean and in the correct condition.
   (9) Connect the electrical connector (2).
Subtask 23-72-22-865-052-A ** ON A/C NOT FOR ALL
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUDOORS/CKPT/VIDEO/SPLY15RAT16
Subtask 23-72-22-710-050-A ** ON A/C NOT FOR ALL
E. Do the operational test of the anti-hijack camera-monitoring-system (Ref. AMM TASK 23-72-00-710-001).
5. Close-up
Subtask 23-72-22-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
Subtask 23-72-22-862-050-A ** ON A/C NOT FOR ALL
B. De-energize the ground service network
(Ref. AMM TASK 24-41-00-862-002)
[Rev.10 from 2021] 2026.04.02 06:12:20 UTC