Installation of the Cockpit Voice Recorder (CVR) Microphone
TASK 23-71-13-400-001-A
Installation of the Cockpit Voice Recorder (CVR) Microphone
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-71-13-860-052-A ** ON A/C NOT FOR ALL
Subtask 23-71-13-420-050-A ** ON A/C NOT FOR ALL
Subtask 23-71-13-860-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:12:19 UTC
Installation of the Cockpit Voice Recorder (CVR) Microphone
CAUTION:
DURING THE INSTALLATION OF THE CVR MICROPHONE, MAKE SURE THAT THE PASSAGE HOLE IN THE LEFT FRONT LINING PANEL IS CONCENTRIC WITH THE MICROPHONE HEAD. THIS WILL MAKE SURE THAT THE MICROPHONE HEAD NEVER TOUCHES THE PANEL EDGES.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | EXTRACTION TOOL - INSERT |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 23-71-00-710-001-A | Operational Check of CVR and CVR-Channel Recording |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-13-41-000-806-A | Removal of Outlet Assembly Panels 211LC and 212LC |
| TASK 25-13-41-400-805-A | Installation of Outlet Assembly Panels 211LC and 212LC |
| ESPM 2032230 | |
| ESPM 2032510 | |
| ESPM 2033300 | |
| ESPM 204221 | |
| ESPM 2044110 | |
| ESPM 2056200 | |
| AWM 237103 | |
| AIPC 24-92-01- | |
Subtask 23-71-13-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
Subtask 23-71-13-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 23-71-13-010-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CVR/SPLY | 2RK | E14 |
| 49VU | COM/CVR/CTL | 4RK | E13 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CVR/SPLY | 23RK | E14 |
| 49VU | COM/CVR/CTL | 26RK | E13 |
C. Get Access to the CVR Microphone
(1) Make sure that the Outlet Assembly Panel is removed to get access to the CVR Microphone. (Ref. AMM TASK 25-13-41-000-806)
4. Procedure(1) Make sure that the Outlet Assembly Panel is removed to get access to the CVR Microphone. (Ref. AMM TASK 25-13-41-000-806)
Subtask 23-71-13-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the CVR Microphone
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Install the cable of the CVR microphone (2) in the protective conduit and put the labels on the protective conduit as given in the ESPM 2032230 and ESPM 2032510 and ESPM 2033300.
(5) Install the cable of the CVR microphone (2) on the connector (8).
(a) Connect the wires of the CVR microphone (2) to the connector (2380VCA) with the EXTRACTION TOOL - INSERT as given in the AWM 237103, ESPM 2056200 and ESPM 2044110.
(7) Make sure that the receptacle (9) is in the correct condition.
(8) Connect the connector (8) to the receptacle (9).
(9) Put the CVR microphone (2) on its support (3).
(10) Install the washers (4) and the screws (1), and tighten the screws.
(11) Put the support (3) with the CVR microphone (2) in position.
(12) Install the washers (13) and the screws (12), and tighten the screws (12).
(13) Make sure that the wire clamp (14) is in the correct condition. Replace the wire clamp (14) if necessary.
(14) Put the wire clamp (14) on the wire of the CVR microphone (2).
(15) Put the wire clamp (14) in position and install the washers (6) and (7), and the screw (5).
(16) Tighten the screw (5).
(17) Put overhead control and indicator panel 25VU (11) in its housing.
(18) Tighten the QAD fasteners (10) by one quarter turn.
Subtask 23-71-13-420-050-B ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Install the cable of the CVR microphone (2) in the protective conduit and put the labels on the protective conduit as given in the ESPM 2032230 and ESPM 2032510 and ESPM 2033300.
(5) Install the cable of the CVR microphone (2) on the connector (8).
(a) Connect the wires of the CVR microphone (2) to the connector (2380VCA) with the EXTRACTION TOOL - INSERT as given in the AWM 237103, ESPM 2056200 and ESPM 2044110.
NOTE: If there is a solder sleeve, you can install it with the ESPM 204221.
NOTE: To find the P/N of the connector, you can refer to the Aircraft Illustrated Parts Catalog (AIPC) of the electrical routing (24-92-01).
(6) Remove the blanking cap from the receptacle (9). (7) Make sure that the receptacle (9) is in the correct condition.
(8) Connect the connector (8) to the receptacle (9).
(9) Put the CVR microphone (2) on its support (3).
(10) Install the washers (4) and the screws (1), and tighten the screws.
(11) Put the support (3) with the CVR microphone (2) in position.
(12) Install the washers (13) and the screws (12), and tighten the screws (12).
(13) Make sure that the wire clamp (14) is in the correct condition. Replace the wire clamp (14) if necessary.
(14) Put the wire clamp (14) on the wire of the CVR microphone (2).
(15) Put the wire clamp (14) in position and install the washers (6) and (7), and the screw (5).
(16) Tighten the screw (5).
(17) Put overhead control and indicator panel 25VU (11) in its housing.
(18) Tighten the QAD fasteners (10) by one quarter turn.
A. Installation of the CVR Microphone
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Install the cable of the CVR microphone (2) in the protective conduit and put the labels on the protective conduit as given in the ESPM 2032230 and ESPM 2032510 and ESPM 2033300.
(5) Install the cable of the CVR microphone (2) on the connector (8).
(a) Connect the wires of the CVR microphone (2) to the connector (2380VCA) with the EXTRACTION TOOL - INSERT as given in the AWM 237103, ESPM 2056200 and ESPM 2044110.
(7) Make sure that the receptacle (9) is in the correct condition.
(8) Connect the connector (8) to the receptacle (9).
(9) Put the CVR microphone (2) on its support (3).
(10) Install the washers (4) and the screws (1), and tighten the screws.
(11) Put the support (3) with the CVR microphone (2) in position.
(12) Install the washers (13) and the screws (12), and tighten the screws (12).
(13) Make sure that the wire clamp (14) is in the correct condition. Replace the wire clamp (14) if necessary.
(14) Put the wire clamp (14) on the wire of the CVR microphone (2).
(15) Put the wire clamp (14) in position and install the washers (6) and (7), and the screw (5).
(16) Tighten the screw (5).
(17) Put overhead control and indicator panel 25VU (11) in its housing.
(18) Tighten the QAD fasteners (10) by one quarter turn.
Subtask 23-71-13-865-052-A ** ON A/C NOT FOR ALL NOTE: On the base of the unit there is an attenuation switch. The default position of the attenuation switch is at 0 dB. It is not permitted to modify the user switch without Airbus approval.
NOTE: On the base of the unit there is a PEAK indicator. This indicator comes on when the microphone input level is more than 120 dB sound pressure level. It is not permitted to modify the user switch without Airbus approval.
(1) Clean the component interfaces and the adjacent area.(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Install the cable of the CVR microphone (2) in the protective conduit and put the labels on the protective conduit as given in the ESPM 2032230 and ESPM 2032510 and ESPM 2033300.
(5) Install the cable of the CVR microphone (2) on the connector (8).
(a) Connect the wires of the CVR microphone (2) to the connector (2380VCA) with the EXTRACTION TOOL - INSERT as given in the AWM 237103, ESPM 2056200 and ESPM 2044110.
NOTE: If there is a solder sleeve, you can install it with the ESPM 204221.
NOTE: To find the P/N of the connector, you can refer to the aircraft illustrated parts catalog of the electrical routing AIPC 24-92-01-.
(6) Remove the blanking cap from the receptacle (9). (7) Make sure that the receptacle (9) is in the correct condition.
(8) Connect the connector (8) to the receptacle (9).
(9) Put the CVR microphone (2) on its support (3).
(10) Install the washers (4) and the screws (1), and tighten the screws.
(11) Put the support (3) with the CVR microphone (2) in position.
(12) Install the washers (13) and the screws (12), and tighten the screws (12).
(13) Make sure that the wire clamp (14) is in the correct condition. Replace the wire clamp (14) if necessary.
(14) Put the wire clamp (14) on the wire of the CVR microphone (2).
(15) Put the wire clamp (14) in position and install the washers (6) and (7), and the screw (5).
(16) Tighten the screw (5).
(17) Put overhead control and indicator panel 25VU (11) in its housing.
(18) Tighten the QAD fasteners (10) by one quarter turn.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 23-71-13-710-051-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CVR/SPLY | 2RK | E14 |
| 49VU | COM/CVR/CTL | 4RK | E13 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CVR/SPLY | 23RK | E14 |
| 49VU | COM/CVR/CTL | 26RK | E13 |
Subtask 23-71-13-860-050-A ** ON A/C NOT FOR ALL
A. Make sure that the work area is clean and clear of tools and other items.
Subtask 23-71-13-010-052-A ** ON A/C NOT FOR ALL Subtask 23-71-13-862-050-A ** ON A/C NOT FOR ALL
CVR Microphone