W DOC AIRBUS | AMM A320F

Removal of the Static Discharger Retainer


TASK 23-61-42-000-001-A
Removal of the Static Discharger Retainer


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 324
ZONE: 326
ZONE: 330
ZONE: 340
ZONE: 530
ZONE: 590
ZONE: 630
ZONE: 690
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 12M (40 FT) - ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
6
SCRAPER - NON METALLIC
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
324
VERTICAL STABILIZER TIP
326
RUDDER
330
THS LH AND LH ELEVATOR
340
THS RH AND RH ELEVATOR
530
L WG FLAP TAB, FLAP TRACK FAIR & WG TIP
590
AILERON
630
RIGHT WING FLAP TRACK FAIR AND WING TIP
690
AILERON
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 23-61-41-000-001-A
Removal of the Static Discharger
TASK 55-44-11-000-001-A
Removal of the Rudder Tip
TASK 57-55-11-000-001-A
Removal of the Flap Track Fairings Nos. 2, 3 and 4
TASK 57-55-11-000-004-A
Removal of the Flap Track Fairings Nos. 2, 3 and 4
SRM 514211
3. Job Set-up
Subtask 23-61-42-941-050-A
A. Safety Precautions
   (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
   (2) In the cockpit, put the WARNING NOTICE(S) in position to tell persons not to operate the flight controls.
Subtask 23-61-42-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B11
49VUFLIGHT CONTROLS/THS/ACTR/MOT219CE2B09
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
49VUAUTO FLT/FAC1/28VDC5CC1B04
49VUAUTO FLT/FAC1/26VAC14CC1B03
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/ELAC1/NORM/SPLY15CE1B06
49VUFLIGHT CONTROLS/THS/ACTR/MOT219CE2B04
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
49VUAUTO FLT/FAC1/28VDC5CC1H10
49VUAUTO FLT/FAC1/26VAC14CC1H09
** ON A/C ALL
105VUFLIGHT CONTROLS/ELAC2/STBY SPLY16CE2A02
105VUFLT CTL/ELAC1/STBY SPLY16CE1A01
121VUAUTO FLT/FAC2/28VDC5CC2M19
121VUAUTO FLT/FAC2/26VAC14CC2M18
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
121VUFLIGHT CONTROLS/THS ACTR/MOT319CE3Q17
121VUFLIGHT CONTROLS/THS ACTR/MOT119CE1Q16
121VUFLIGHT CONTROLS/ELAC2/NORM/SPLY15CE2R20
Subtask 23-61-42-010-050-A
C. Get Access
   (1) Put the ACCESS PLATFORM 12M (40 FT) - ADJUSTABLE below the applicable static discharger.
   (2) Remove the applicable static discharger (Ref. AMM TASK 23-61-41-000-001).
4. Procedure
Subtask 23-61-42-020-051-A
A. Removal of the Static Discharger Retainers from Zones 324 (Vertical Stabilizer Tip), 326 (Rudder) and 330 (340) (Trimmable Horizontal Stabilizer (THS))

   (1) Remove the sealant with the SCRAPER - NON METALLIC from the rivets, static discharger retainers and supports, as applicable:
     (a) For the static discharger retainers installed on the vertical stabilizer:
       1 On the vertical stabilizer tip, remove the sealant from:
  • The rivets (4)
  • Around the retainer (3).
       2 On the rudder, remove the sealant from:
  • The rivets (2) and (4)
  • Around the retainers (1) and (3).
     (b) For the static discharger retainers installed on the THS:
       1 On the elevator, remove the sealant from:
  • The rivets (11), (12), (14), (16) and (17)
  • Around the retainers (10), (13) and (15) and the adapter (9).
       2 On the THS tip, remove the sealant from:
  • The rivets (6) and (8)
  • Around the retainer (7) and the adapter (5).
   (2) For the applicable static discharger retainer(s), remove the rivets SRM 514211.
CAUTION: WHEN YOU REMOVE THE RIVETS, BE CAREFUL NOT TO CAUSE THE RIVET HOLES TO BECOME TOO LARGE. IF YOU DO NOT OBEY THIS PRECAUTION, IT WILL BE NECESSARY TO DO A REPAIR OF THE APPLICABLE ZONE BEFORE YOU INSTALL NEW RIVETS.
     (a) For the static discharger retainers installed on the vertical stabilizer:
       1 Remove the rivets (4) from the vertical stabilizer tip.
       2 Remove the rivets (2) from the rudder trailing edge.
       3 Remove the rudder tip (Ref. AMM TASK 55-44-11-000-001).
       4 Remove the rivets (4) from the rudder tip.
     (b) For the static discharger retainers installed on the THS:
       1 Remove the rivets (11), (12), (14), (16) and (17) from the elevator.
       2 Remove the rivets (6) and (8) from the THS tip.
   (3) Remove the static discharger retainers and supports as applicable:
     (a) For the static discharger retainers installed on the vertical stabilizer:
       1 Remove the retainer (3) from the vertical stabilizer tip.
       2 Remove the retainer (1) from the rudder trailing edge.
       3 Remove the retainer (3) from the rudder tip.
     (b) For the static discharger retainers installed on the THS:
       1 Remove the retainer (15) and the shim (18) from the trailing edge of the elevator.
       2 Remove the retainer (13) from the trailing edge of the elevator.
       3 Remove the retainer (10) and the adapter (9) from the elevator tip.
       4 Remove the retainer (7) and the adapter (5) from the THS tip.
Subtask 23-61-42-020-052-C ** ON A/C NOT FOR ALL
B. Removal of the Static Discharger Retainers from Zones 470 (480) (Engine Pylon), 531 (631), 532 (632) and 533 (633) (Flap Track Fairings)
   (1) Remove the sealant with the SCRAPER - NON METALLIC from the rivets and the static discharger retainers as applicable:
     (a) For the static discharger retainers installed on the flap-track fairing 2, flap-track fairing 3 and flap-track fairing 4:
       1 Remove the sealant from:
  • The rivets (2) and (3)
  • Around the retainer (4).
     (b) For the static discharger retainers installed on the engine pylon:
       1 Remove the sealant from:
  • The rivets (11)
  • Around the retainer (10).
   (2) For the applicable static discharger retainer(s), remove the rivets SRM 514211.
CAUTION: WHEN YOU REMOVE THE RIVETS, BE CAREFUL NOT TO CAUSE THE RIVET HOLES TO BECOME TOO LARGE. IF YOU DO NOT OBEY THIS PRECAUTION, IT WILL BE NECESSARY TO DO A REPAIR OF THE APPLICABLE ZONE BEFORE YOU INSTALL NEW RIVETS.
     (a) For the static discharger retainers installed on flap-track fairing 2, flap-track fairing 3 and flap-track fairing 4:
       1 Remove the top cover (1) from the flap track fairing (Ref. AMM TASK 57-55-11-000-001) or (Ref. AMM TASK 57-55-11-000-004).
       2 Remove the nut (5), washer (6), bolt (8) and disconnect the bonding lead (7) from the plate (9).
       3 Remove the rivets (2) and (3) from the flap track fairing.
     (b) For the static discharger retainer installed on the engine pylon, remove the rivets (11).
   (3) Remove the static discharger retainers and supports as applicable:
     (a) For the static discharger retainers installed on flap-track fairing 2, flap-track fairing 3 and flap-track fairing 4:
       1 Remove the retainer (4).
       2 Remove the plate (9).
     (b) For the static discharger retainer on the engine pylon, remove the retainer (10).
Subtask 23-61-42-020-052-D ** ON A/C NOT FOR ALL
B. Removal of the Static Discharger Retainers from Zones 531 (631), 532 (632) and 533 (633) (Flap Track Fairings)
   (1) Remove the sealant with the SCRAPER - NON METALLIC from the rivets and the static discharger retainers as applicable:
     (a) For the static discharger retainers installed on flap-track fairing 2, flap-track fairing 3 and flap track fairing 4:
       1 Remove the sealant from:
  • The rivets (2) and (3)
  • Around the retainer (4).
   (2) For the applicable static discharger retainer(s), remove the rivets SRM 514211.
CAUTION: WHEN YOU REMOVE THE RIVETS, BE CAREFUL NOT TO CAUSE THE RIVET HOLES TO BECOME TOO LARGE. IF YOU DO NOT OBEY THIS PRECAUTION, IT WILL BE NECESSARY TO DO A REPAIR OF THE APPLICABLE ZONE BEFORE YOU INSTALL NEW RIVETS.
     (a) For the static discharger retainers installed on flap-track fairing 2, flap-track fairing 3 and flap-track fairing 4:
       1 Remove the top cover (1) from the flap track fairing (Ref. AMM TASK 57-55-11-000-001) or (Ref. AMM TASK 57-55-11-000-004).
       2 Remove the nut (5), washer (6), bolt (8) and disconnect the bonding lead (7) from the plate (9).
       3 Remove the rivets (2) and (3) from the flap track fairing.
   (3) Remove the static discharger retainers and supports as applicable:
     (a) For the static discharger retainers installed on flap-track fairing 2, flap-track fairing 3 and flap-track fairing 4:
       1 Remove the retainer (4).
       2 Remove the plate (9).
Subtask 23-61-42-020-053-A ** ON A/C NOT FOR ALL
C. Removal of the Static Discharger Retainers from Zone 590 (690) (Ailerons)

   (1) Remove the sealant with the SCRAPER - NON METALLIC from:
  • The rivets (7), (8), (11) and (12)
  • Around the retainers (10) and (14).
   (2) For the applicable static discharger retainer(s), remove the rivets SRM 514211.
CAUTION: WHEN YOU REMOVE THE RIVETS, BE CAREFUL NOT TO CAUSE THE RIVET HOLES TO BECOME TOO LARGE. IF YOU DO NOT OBEY THIS PRECAUTION, IT WILL BE NECESSARY TO DO A REPAIR OF THE APPLICABLE ZONE BEFORE YOU INSTALL NEW RIVETS.
     (a) Remove the rivets (7), (8), (11) and (12).
   (3) Remove the retainer (10), then remove and discard washer (9).
   (4) Remove the retainer (14), then remove and discard washers (13).
Subtask 23-61-42-020-053-B ** ON A/C NOT FOR ALL
C. Removal of the Static Discharger Retainers from Zone 590 (690) (Ailerons)

   (1) Remove the sealant with the SCRAPER - NON METALLIC from:
  • The rivets (1) and (3)
  • Around the retainer (2).
   (2) For the applicable static discharger retainer(s), remove the rivets SRM 514211.
CAUTION: WHEN YOU REMOVE THE RIVETS, BE CAREFUL NOT TO CAUSE THE RIVET HOLES TO BECOME TOO LARGE. IF YOU DO NOT OBEY THIS PRECAUTION, IT WILL BE NECESSARY TO DO A REPAIR OF THE APPLICABLE ZONE BEFORE YOU INSTALL NEW RIVETS.
     (a) Remove the rivets (1) and (3).
   (3) Remove the retainer (2) from the aileron.
Subtask 23-61-42-020-054-D ** ON A/C NOT FOR ALL
D. Removal of the Static Discharger Retainers from Zone 534 (634) (Wing-Tip)

   (1) Remove the sealant with the SCRAPER - NON METALLIC from:
  • The rivets (1) and (3)
  • Around the retainer (2).
   (2) For the applicable static discharger retainer(s), remove the rivets SRM 514211.
CAUTION: WHEN YOU REMOVE THE RIVETS, BE CAREFUL NOT TO CAUSE THE RIVET HOLES TO BECOME TOO LARGE. IF YOU DO NOT OBEY THIS PRECAUTION, IT WILL BE NECESSARY TO DO A REPAIR OF THE APPLICABLE ZONE BEFORE YOU INSTALL NEW RIVETS.
     (a) Remove the rivets (1) and (3).
   (3) Remove the retainer (2).
Subtask 23-61-42-020-055-D ** ON A/C NOT FOR ALL
E. Removal of the Static Discharger Retainers from Zone 534 (634) (Wing-Tip Fence)

   (1) If necessary, remove the sealant with the SCRAPER - NON METALLIC from:
  • The rivets (1), (2), (6) and (8)
  • Around the retainers (3), (5) and (9), and the packers (4) and (7).
   (2) For the applicable static discharger retainer(s), remove the rivets SRM 514211.
CAUTION: WHEN YOU REMOVE THE RIVETS, BE CAREFUL NOT TO CAUSE THE RIVET HOLES TO BECOME TOO LARGE. IF YOU DO NOT OBEY THIS PRECAUTION, IT WILL BE NECESSARY TO DO A REPAIR OF THE APPLICABLE ZONE BEFORE YOU INSTALL NEW RIVETS.
     (a) Remove the rivets (1), (2), (6) and (8).
   (3) Remove the retainers (3), (5) and (9), and the packers (4) and (7).
Subtask 23-61-42-020-055-E ** ON A/C NOT FOR ALL
E. Removal of the Static Discharger Retainers from Zone 534 (634) (Wing-Tip Fence)
   (1) If necessary, remove the sealant with the SCRAPER - NON METALLIC from:
  • The rivets (1), (4) and (6)
  • Around the retainers (2), (5) and (7), and the packer (3).
   (2) For the applicable static discharger retainer(s), remove the rivets SRM 514211.
CAUTION: WHEN YOU REMOVE THE RIVETS, BE CAREFUL NOT TO CAUSE THE RIVET HOLES TO BECOME TOO LARGE. IF YOU DO NOT OBEY THIS PRECAUTION, IT WILL BE NECESSARY TO DO A REPAIR OF THE APPLICABLE ZONE BEFORE YOU INSTALL NEW RIVETS.
     (a) Remove the rivets (1), (4) and (6).
   (3) Remove the retainers (2), (5) and (7), and the packer (3).
Subtask 23-61-42-020-056-A ** ON A/C NOT FOR ALL
F. Removal of the Static Discharger Retainers from Zone 534 (634) (Sharklet)
   (1) If necessary, remove the sealant with the SCRAPER - NON METALLIC from the rivets and around the static discharger retainers.
   (2) For the applicable static discharger retainer(s), remove the rivets SRM 514211.
CAUTION: WHEN YOU REMOVE THE RIVETS, BE CAREFUL NOT TO CAUSE THE RIVET HOLES TO BECOME TOO LARGE. IF YOU DO NOT OBEY THIS PRECAUTION, IT WILL BE NECESSARY TO DO A REPAIR OF THE APPLICABLE ZONE BEFORE YOU INSTALL NEW RIVETS.
     (a) Remove the rivets (1) from the retainer (2).
     (b) Remove the rivets (3), (4), (5) and (6) from the retainer (7).
     (c) Remove the rivets (8), (9) and (10) from the retainer (11).
     (d) Remove the rivets (12), (13), (14), (15) and (16) from the retainer (17).
     (e) Remove the rivets (18), (19), (20) and (21) from the retainer (22).
   (3) Remove the retainers (2), (7), (11), (17) and (22).
[Rev.10 from 2021] 2026.04.02 06:12:17 UTC