Removal of the SELCAL Code Panel
TASK 23-51-13-000-001-A
Removal of the SELCAL Code Panel
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-51-13-010-050-A
Subtask 23-51-13-020-050-A
[Rev.10 from 2021]
2026.04.02 06:12:16 UTC
Removal of the SELCAL Code Panel
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 23-51-13-010-050-A
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in the zone 128.
(2) Open the access door 824.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824 in the zone 128.
(2) Open the access door 824.
Subtask 23-51-13-020-050-A
A. Removal of the SELCAL Code Panel
(1) Write the code which is in view on the SELCAL code panel (3).
(2) Loosen the fasteners (2) by one quarter turn.
(3) Pull the SELCAL code panel (3) from its housing.
(4) Disconnect the connector (4) from the receptacle (1).
(5) Remove the SELCAL code panel (3).
(6) Put CAP - BLANKING on the connector (4) and on the receptacle (1).
(1) Write the code which is in view on the SELCAL code panel (3).
(2) Loosen the fasteners (2) by one quarter turn.
(3) Pull the SELCAL code panel (3) from its housing.
(4) Disconnect the connector (4) from the receptacle (1).
(5) Remove the SELCAL code panel (3).
(6) Put CAP - BLANKING on the connector (4) and on the receptacle (1).
SELCAL Code Panel