W DOC AIRBUS | AMM A320F

BITE Test of the Audio Management Unit (AMU)


TASK 23-51-00-740-002-A
BITE Test of the Audio Management Unit (AMU)


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
NOTE: You can do the test in the hangar.
ZONE: 210
1. Reason for the Job
To make sure that the Audio Management Unit (AMU) and the Audio Control Panels (ACPs) or Radio Management Panels (RMPs) operate correctly.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-003-A
Procedure to Get Access to the SYSTEM REPORT/TEST/COM Page
3. Job Set-up
Subtask 23-51-00-860-056-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
   (2) On all the ACPs, make sure that:
  • The RAD/INT switch is in the middle position,
  • All transmission pushbutton switches are fully out,
  • All reception pushbutton switches are pushed (no reception).
   (3) On the maintenance panel 50VU, make sure that the SVCE INT OVRD pushbutton switch is not pushed.
   (4) On the overhead control and indicating panel 48VU, make sure that the AUDIO SWITCHING selector switch is in the NORM position.
Subtask 23-51-00-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM/AUDIO/ACP/F/O5RNG07
** ON A/C NOT FOR ALL
49VUCOM/AUDIO/FLT/INTPH9RNG08
49VUCOM/AUDIO/ACP/CAPT4RNG06
** ON A/C NOT FOR ALL
49VUCOM/ACP F/O/BITE/ INT 2 AUDIO/3&5 OCCPNT5RNG07
** ON A/C NOT FOR ALL
49VUCOM/INT/1+29RNG08
49VUCOM/ACP CAPT/SELCAL/INT 1 AUDIO/AVNCS4RNG06
** ON A/C ALL
121VUCOM NAV/SELCAL8RNM04
121VUCOM NAV/ACP/THIRD/OCCPNT6RNM02
** ON A/C NOT FOR ALL
121VUCOM NAV/ACP/FOURTH/OCCPNT20RNM01
4. Procedure
Subtask 23-51-00-710-056-A
A. On one MCDU, get the SYSTEM REPORT/TEST COM menu page (Ref. AMM TASK 31-32-00-860-003).
Subtask 23-51-00-740-050-A ** ON A/C NOT FOR ALL
B. Do the BITE test:
ACTION
RESULT
1.On the MCDU, on the COM menu page:
  • Push the line key adjacent to the AMU indication.
On the MCDU:
  • the AIS page comes into view.
2.On the AIS page:

  • Push the line key adjacent to the TEST indication.
  • The TEST IN PROGRESS XX s comes into view.
  • The TEST OK page comes into view.
3.On the MCDU:

  • Push the line key adjacent to the RETURN indication until the CFDS menu page comes into view.

5. Close-up
Subtask 23-51-00-862-053-A
A. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:50:54 UTC