W DOC AIRBUS | AMM A320F

Installation of the Jack - Maintenance Interphone


TASK 23-44-41-400-002-A
Installation of the Jack - Maintenance Interphone


ZONE: 210
ZONE: 410
ZONE: 420
ZONE: 430
ZONE: 440
FIN: 4000RJ1 ** ON A/C NOT FOR ALL
FIN: 4000RJ2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 44 and 36 lbf.in (0.50 and 0.41 m.daN ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
410
ENG 1 PYLON BOX AND FORWARD FAIRING
420
ENG 2 PYLON BOX AND FORWARD FAIRING
430
ENG 1 AIR INTAKE, FAN AND ACCESS GEARBOX
440
ENG 2 AIR INTAKE, FAN AND ACCESS GEARBOX
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 23-44-00-700-001-A
Operational Test of the Service Interphone
TASK 70-23-15-912-010-A
Connection of Electrical Connectors
3. Job Set-up
Subtask 23-44-41-860-054-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On the panel 115VU:
  • Make sure that the WARNING NOTICE(S) to tell persons not to start the engine 1(2) is in position.
   (2) Make sure that the engine 1(2) has been shutdown for at least 5 minutes.
   (3) On the panel 50VU:
  • Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
  • Make sure that the WARNING NOTICE(S) is installed.
Subtask 23-44-41-865-064-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 101RH (DIRCIDS, 1)
49VUAIR COND/CIDS/SDF/DIR1 ESS15WHC05
49VUCOM/CIDS/DIR ESS/1150RHG01
121VUCOM NAV/CIDS/DIR NORM/1151RHM06
121VUCOM/CIDS/DIR 1/BAT147RHP13
122VUAIR COND/CIDS/SDF/DIR NORM/117WHT17
FOR FIN: 102RH (DIRCIDS, 2)
49VUAIR COND/CIDS/SDF/DIR2 ESS18WHC06
49VUCOM DIR ESS/2157RHG02
49VUCOM/CIDS/DIR ESS/1150RHG01
121VUCOM NAV/CIDS/DIR NORM/2156RHM07
121VUCOM NAV/CIDS/DIR NORM/1151RHM06
121VUCOM/CIDS/DIR 2/BAT146RHP14
122VUAIR COND/CIDS/SDF/DIR NORM/214WHT18
4. Procedure
Subtask 23-44-41-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the Maintenance Interphone Jack
   (1) Install the clips, from the removed harness, to the replacement harness.
   (2) Remove the covers/caps/plugs from the electrical connector and the electrical receptacle.
   (3) Make sure that the anti-ice access panel has no damage.
   (4) Install the interphone harness.
     (a) Put the harness (6) in the air intake cowl and attach the maintenance interphone jack (2) with the screws (1).
     (b) Attach the harness clips (3) to the cowl with the bolts (4).
     (c) Torque the bolts (4) to between 44 and 36 lbf.in (0.50 and 0.41 m.daN ) T.
   (5) Connect the electrical connector (5) (
Ref. AMM TASK 70-23-15-912-010).
Subtask 23-44-41-410-050-A ** ON A/C NOT FOR ALL
B. Install the anti-ice access panel.
   (1) Put the access panel (7) on the air intake cowl.
   (2) Attach the access panel with the bolts (8).
Subtask 23-44-41-865-065-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 101RH (DIRCIDS, 1)
49VUAIR COND/CIDS/SDF/DIR1 ESS15WHC05
49VUCOM/CIDS/DIR ESS/1150RHG01
121VUCOM NAV/CIDS/DIR NORM/1151RHM06
121VUCOM/CIDS/DIR 1/BAT147RHP13
122VUAIR COND/CIDS/SDF/DIR NORM/117WHT17
FOR FIN: 102RH (DIRCIDS, 2)
49VUAIR COND/CIDS/SDF/DIR2 ESS18WHC06
49VUCOM DIR ESS/2157RHG02
49VUCOM/CIDS/DIR ESS/1150RHG01
121VUCOM NAV/CIDS/DIR NORM/2156RHM07
121VUCOM NAV/CIDS/DIR NORM/1151RHM06
121VUCOM/CIDS/DIR 2/BAT146RHP14
122VUAIR COND/CIDS/SDF/DIR NORM/214WHT18
Subtask 23-44-41-710-052-A ** ON A/C NOT FOR ALL
D. Do the test of the service interphone system (Ref. AMM TASK 23-44-00-700-001).
5. Close-up
Subtask 23-44-41-942-050-A ** ON A/C NOT FOR ALL
A. Remove the warning notices.
[Rev.10 from 2021] 2026.04.02 06:12:14 UTC